1.Analysis of the risk factors between anterior and posterior intracranial artery stenosis in acute stroke patients
Yanqiang CHEN ; Xueping ZHANG ; Hongzhong BAI ; Liheng ZHENG ; Qing ZHANG
Clinical Medicine of China 2013;29(9):897-900
Objective To investigate the association between vascular risk factors and the location of intracranial artery stenosis (anterior versus posterior).Methods Magnetic resonance angiography(MRA) were examined in 374 acute stroke patients.It was divided into two groups (anterior and posterior intracranial artery stenosis group).Analyzed possible risk factors.Results Univariate analysis showed there were differences between anterior and posterior intracranial artery stenosis in systolic blood pressure,history of smoking,drinking and stroke status,and national institutes of health stroke scale (NIHSS) score at discharge,short-term prognosis,serum creatinine,triglyceride,low density lipoprotein cholesterol (LDL-C) (P < 0.05).In multivariate logistic regression analysis,high blood sugar (OR =1.135,95% CI:1.003-1.284),history of stroke(OR =1.133,95% CI:1.007-1.276),good short-term prognosis (OR =5.987,95% CI:1.441-24.873) were preferentially related to anterior intracranial artery stenosis,whereas history of smoking (OR =0.003,95 % CI:0.000-0.376),high serum creatinine values (OR =0.509,95 % CI:0.328-0.790),high triglyceride values (OR =0.054,95% CI:0.004-0.645) and high LDL-C values (OR =0.096,95% CI:0.015-0.608) were preferentially related to posterior intracranial artery stenosis.Conclusion Vascular risk factors appeared to exert different effects of risk for anterior and posterior intracranial artery stenosis.
2.Oligonucleotide Hybridization Detection Based on Surface Plasmon Resonance Technology
Xueyong LIU ; Yanqiang BAI ; Chunyan WANG ; Zhongquan DAI ; Yinghui LI
Space Medicine & Medical Engineering 2006;0(01):-
Objective To establish a kind of detection technique of nucleic acid based on surface plasmon resonance(SPR) and to set up the foundation of real-time, online space microbial detection. Methods A portable online bio-molecules analyzer based on SPR biosensor was applied. The probe was mercapto-modified at the 5’ end and immobilized on the sensor surface. Then the target sequences in the solution were monitored and sensitivity, specificity and reproducibility of the method were investigated. Results The results showed that detection method with good specificity and sensitivity could realize online detection of target sequence. The system could detect 2.3 nmol/L target sequence, CV value of nine detections was 3.5% and that of thirty detections was 14.7%. Conclusion The established nucleic acid detection method has the advantage of high sensitivity, good specificity and reproducibility, which can be applied in the field of nucleic acid detection.