1.Application of Cisatracurium in Hiatal Hernia Repair of Newborn
China Pharmacy 2005;0(23):-
OBJECTIVE: Approach to the pharmacodynamics of cisatracurium in newborn. METHODS: Sixty patients were randomized to two groups: Group Ⅰ and Group Ⅱ , received( iv) 2ED95 or 3ED95 cisatracurium in 5 seconds respectively, n=30. Neuromuscular transmission was monitored and Intubation conditions were assessed at 120s after cisatracurium administration using a 4- part scale. Observe onset time, TOF no reaction period, duration of action, recovery index, duration in vivo. RESULTS: The muscular blockage and conditions of intubation after 120s were different between two groups( P0. 05) . CONCLUSIONS: 3ED95 cisatracurium produces quicker, safer onset time and acceptable intubating conditions in the great majority of newborn than 2ED95. The TOF no reaction period, duration of action and duration in vivo were longer in 3ED95 group than in 2ED95 group, but recovery index are no significant between 2 groups with dosage.
2.Effects of Antenatal Dexamethasone on Cerebral Intra and Extra-cellular Calcium Concentrations in Asphyxiated Rat Fetuses
Shaohan NONG ; Yanming XIE ; Xiaosui HUANG
Chinese Journal of Perinatal Medicine 1998;0(03):-
Objective To investigate whether antenatal administration of dexamethasone would provide protection against cerebral hypoxic ischemic damage in asphyxiated fetal rats. Methods Fifty seven fetal rats of twenty day gestational age were randomly divided into five groups: sham operation (normal control, n =11), asphyxiated control (group E, n =10), and group D 1?D 2?D 3 of different timings of intravenous dexamethasone treatment (1 mg/kg) in pregnant SD rats ( n =15, 12, and 9 respectively). The times assigned for dexamethasone injection were thirty minutes before clamping, the time aroung clamping and the beginning of reperfusion respectively. Intra and extra cellular concentrations of calcium, sodium and potassium in fetal rat brains were measured in each group after thirty minutes of reperfusion. Results (1)Intracellular free calcium concentrations of fetal rat brains in group E,D 1, D 2 and D 3 were 552?94, 438?105, 445?57, and 456?110 nmol/L respectively, and all significantly higher than that in the normal control 315?87 nmol/L ( P
3.Dynamic changes of BALF and serum IL-8 and IL-6 levels in patients with lower respiratory tract infection.
Yanming HUANG ; Wanli ZUO ; Kangxin ZHANG
Chinese Journal of Practical Internal Medicine 2003;0(01):-
Objective To investigate the relationship between interleukin-8 (IL-8),interleukin-6 (IL-6) and pathogenesis of lower respiratory infection(RI).Methods Bronchoalveolar lavage fluid (BALF) and serum IL-8,IL-6 levels were detected by enzyme linked immunosorbent assay (ELISA) in 36 patients with lower RI,28 patients with unstable asthma and 12 controls. Neutrophils (PMN) and alveolar macrophages (AMs) of BALF were examined.Results The levels of serum IL-8 and IL-6 of RI before treatment were significantly higher than those of RI after treatment,of unstable asthma,and of controls (P
4.Clinical application of the obturator nerve block beside vessel in transurethral resection of bladder tumor
Xindan DU ; Fan TAO ; Yanming HUANG
China Journal of Endoscopy 2016;22(2):7-10
Objective To compare the operational feasibility and efficacy of inguinal obturator nerve block (ONB) beside the vessel by ultrasound combined with nerve stimulation and traditional ONB guided by nerve stimulation preventing obturator nerve reflex. Methods Forty patients with American Society of Anesthesiology (ASA)Ⅰ or Ⅱ, aged 35~91 years who underwent transurethral electric excision of bladder tumor in our hospital in 2014 were ran-domly divided into beside vessel group (group V, = 20) and traditional group (group T, = 20). Adductor strength was measured before and after the block. Frequencies of obturator nerve block puncture, operation time, visual ana-log scale (VAS) pain score, and incidence of complications were recorded during and after ONB. Results The suc-cess rate of the first puncture was significantly higher in group V than that in group T ( <0.01). The operation time in group V was significantly shorter than that in group T ( < 0.01). The decreased degree of adductor strength has significant difference of the two groups ( < 0.05 or < 0.01). The VAS pain score in group T was higher than that in groups V ( < 0.01). There are two cases contract blood vessel in group T, while none in group V ( < 0.01). There was no case with the local anesthetic toxicity and paresthesia in the area of the obturator nerve and the obtu-rator nerve injury in the two groups. Conclusion Compared with traditional ONB guided by nerve stimulation, in-guinal ONB beside the vessel by ultrasound combined with nerve stimulation showed more accurate positioning, less adjustment, less puncture time, more comfortable and safe.
5.Clinical observation of the application of dezocine combined with fentanyl in high intensity focused ultrasound in the treatment of uterine fibroids
Dongmei YAO ; Shuijuan ZHANG ; Yanming HUANG ; Aiguo ZHANG ; Zhichun JIN
Chongqing Medicine 2015;(2):189-191
Objective To observe the feasibility of combining dezocine with fentanyl in the application of single integral high in‐tensity focused ultrasound(HIFU)ablation of uterine fibroids .Methods One hundred and sixty patients with uterine fibroids trea‐ted by HIFU under conscious sedation were randomly divided into 2 groups(n=80):group A with treatment combined fentanyl and midazolam and group B treated with combined dezocine ,fentanyl and midazolam .Analgesic effect was evaluated with visual analog scale (VAS) .Variation of patients′vital signs (blood pressure ,heart rate ,electrocardiogram ,oxygen saturation) ,pain scores ,com‐fort scores ,sedation scores ,analgesic consumption and side effects were recorded before treatment (T0 ) ,during drug delivery (T1 ) , at the beginning of the treatment(T2 ) ,30 minutes after drug delivery (T3 ) ,at the end of the treatment(T4 ) ,2 hours after treatment (T5 ) ,4 hours after treatment (T6 ) ,8 hours after treatment (T7 )and 24 hours after treatment(T8 ) .Results Both groups showed reliable analgesic effects and vital signs of each time point were stable .VAS scores and Ramsay scores of group A were higher than those of group B ,but there was no statistical difference (P>0 .05) .Three patients in group A showed dysuria and relieved after symptomatic treatment .No respiratory depression occurred in both groups .But compared to group A ,the incidence of the analgesic side effects of group B was significantly lower and patients satisfaction was significantly higher(P<0 .05) .Conclusion The analge‐sic effects of dezocine combined with fentanyl are reliable in HIFU ablation of uterine fibroids with fewer side effects ,and could be worthy to be promoted in clinical use .
6.Investigation on recheck rule of child urine analysis
Yanming HE ; Shuwen YAO ; Yujun HUANG ; Bingshao LIANG ; Haiying LIU
International Journal of Laboratory Medicine 2015;(6):738-739,742
Objective To investigate the recheck rule by investigating the coincidence rate of the results detected by the LabU‐Mat urine dry chemistry analyzer and the Urised tangible composition analyzer with the results detected by the microscope examina‐tion .Methods 1 040 urine specimens from children outpatients and children inpatients were collected .Firstly ,the specimens were analyzed by the LabUMat urine dry chemistry analyzer and the Urised tangible composition analyzer ,and then detected by using the microscopic examination for investigating the recheck rule of the routine analysis by the urine automatic analyzer ;the regulation was evaluated by the missed detection rate ,and then the recheck rule avoiding the missed diagnosis of abnormal renal function was also evaluated .Finally ,clinically verify the rules adopting 200 specimens to perform the clinical verification on this recheck rule .Results Among the specimens used for researching the recheck rule ,the specimens of positive microscope examination results accounted for 58 .65% ,the specimens of negative results accounted for 41 .35% .In the positive detection specimens ,the specimens of RBC positive were the majority ,accounting for 50% ,the specimens of WBC positive accounted for 23 .08% and the specimens of CAST positive accounted for 7 .69% .The coincidence rate of the set rule was 87 .5% and the missed detection rate was 2 .9% .In conduc‐ting the verification on the recheck rule by 200 urine specimens ,the coincidence rate was 89 .52% and the missed detection rate was 2 .4% .Conclusion When the detection results of occult blood(BLD) ,WBC(LEU) and protein(PRO) by the dry chemistry analyzer and the detection results of RBC ,WBC ,CAST by the tangible composition analyzer are inconsistent or the differences among them are beyond 2 grades of differential ,the recheck by the microscopic examination should be performed .
7.Change in antimicrobial resistance of Acinetobacter baumannii causing hospital-acquired pneumonia
Peng ZHANG ; Weijun OU ; Yanbin ZHOU ; Yanming HUANG
Chinese Journal of Infection Control 2015;(9):626-628,632
Objective To investigate antimicrobial resistance of Acinetobacter baumannii (A.baumannii)causing hospital-acquired pneumonia (HAP),so as to guide rational use of antimicrobial agents and reduce antimicrobial re-sistant rate.Methods Clinical data of patients with A.baumannii HAP in a hospital between 2009 and 2012 were collected and analyzed retrospectively.Antimicrobial resistance data were summarized and analyzed statistically ac-cording to uniformed methods.Results A total of 284 patients developed A.baumannii HAP,patients mainly distributed in intensive care unit(45.07%),department of respiratory diseases(19.01%),neurosurgery (9.15%),and neurology (5.99%).The incidences of A.baumannii HAP,multidrug-resistant A.baumannii (MDR-AB)HAP,and extensively drug-resistant A.baumannii (XDR-AB)HAP increased year by year.The total resistant rates of A.baumannii to cef-operazone/sulbactam (9.51%)and minocycline(9.86%)were low,to levofloxacin(43.66%)and ciprofloxacin(45.42%) were relatively higher;resistant rates to imipenem and meropenem were 16.20%and 20.42% respectively.The resistant rates to meropenem,imipenem,cefoperazone/sulbactam,and ampicillin/sulbactam increased year by year (all P <0.05). Conclusion Antimicrobial resistance of A.baumannii is serious,it is essential to strengthen the monitoring of antimicrobial resistance of A.baumannii,and prevent the spread in hospital.
8.Preparation of elastic porous cell scaffold fabricated with combined polydimethylsiloxane (PDMS) and hydroxyapatite (HA).
Yang YANG ; Ding LAN ; Yan HUANG ; Yanming LI ; Yuren WANG ; Lianwen SUN ; Yubo FAN
Journal of Biomedical Engineering 2014;31(3):625-631
Polydimethylsiloxane (PDMS) and hydroxyapatite (HA) were combined in our laboratory to fabricate an elastic porous cell scaffold with pore-forming agent, and then the scaffold was used as culture media for rat bone marrow derived mesenchymal stem cells (rBMSCs). Different porous materials (square and circular in shape) were prepared by different pore-forming agents (NaCl or paraffin spheres) with adjustable porosity (62%-76%). The HA crystals grew on the wall of hole when the material was exposed to SBF solutions, showing its biocompatibility and ability to support the cells to attach on the materials.
Animals
;
Biocompatible Materials
;
chemistry
;
Dimethylpolysiloxanes
;
chemistry
;
Durapatite
;
chemistry
;
Mesenchymal Stromal Cells
;
cytology
;
Porosity
;
Rats
;
Tissue Scaffolds
9.The relationship between hypertensive disorder complicating pregnancy and serum free estriol and its impact on pregnancy outcomes
Lihua FU ; Yujie GAN ; Yanming GUAN ; Xihuan HUANG ; Jinwen GAO ; Fengping JIAN
Chinese Journal of Primary Medicine and Pharmacy 2013;20(1):11-13
Objective To research the relationship between hypertensive disorder complicating pregnancy and serum free estriol 3 (FE3) and explore its impact on pregnancy outcome.Methods Clinical data of 117 hypertensive disorder complicating pregnancy and 165 normal pregnant women were retrospectivly analyzed.Chemiluminescence immunoassay determination of maternal serum FE3 also had been conducted.Then analyzing the correlation between hypertensive disorder complicating pregnancy and FE3 and its impact on pregnancy outcomes.Results LDL cholesterol and the level of creatinine of observation group were significantly lower than the control group(t =3.129,9.372,all P < 0.05),while blood pressure,triglycerides,HDL,and 24-hour urinary protein content were significantly higher than control groug(t =7.361,2.398,2.833,all P < 0.05).The FE3 level of the observation group were significantly lower than the control group (t =2.913,P < 0.05).There was a significant positive correlation between the FE3 level of normal pregnant women and their gestational age (r =0.937,P < 0.05).The probabilities of premature birth,premature rupture of membranes,postpartum hemorrhage,and neonatal asphyxia of observation group were significantly higher than amtrol group (x2 =3.912,3.879,4.267,6.935,all P < 0.05).Conclusion There is a significant correlation between hypertensive disorder complicating pregnancy and FE3,which has an important significance on monitoring the health status of pregnant women and the fetal-placental function.
10.Performance evaluation of 20 blood glucose meters for home use testing
Junhan WANG ; Gang HUANG ; Rong LU ; Hong JIANG ; Min FENG ; Wei YAO ; Yanming CHEN ; Hongyun HU
International Journal of Laboratory Medicine 2015;(6):808-810
Objective To evaluate the precision and accuracy of blood glucose meter(BGM ) for community home use testing . Methods According to the In Vitro Diagnostic Test Systems‐Requirements for Blood Glucose Monitoring Systems for Self‐Testing in Managing Diabetes Mellitus in DIN EN ISO15197 :2013 .Capillary blood and venous blood were tested by BGM and the laborato‐ry biochemical analyzer respectively .The measurement results of each BGM were compared with the results of the biochemical ana‐lyzer for conducting the bias analysis .Results In evaluated 20 BGM ,none of them met the requirements of ISO15197 :2013(when blood glucose concentrations < 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 0 .83 mmol/L ;when blood glucose concentrations ≥ 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 15% .Only 11 imported BGM (55% ) met the state standard .Conclusion The bias of 20 BGM ranged - 28 .7% - 3 .8% ,with the average bias of - 12 .2% . These detection results will bring the large risk of therapy in the diabetic patients .The regular and standardized evaluation of BGM performance may ensure the quality of blood glucose self - monitoring .