1.Study of Projection Angle for Multiple Pelvic Fractures
Chinese Medical Equipment Journal 2003;0(10):-
Objective To explore the multiple pelvic fractures projection methods and value. Methods 50 cases of pelvic trauma patients were divided into two groups for control photography, and underwent X-ray examination with different projection angles. Results The display effect of the image of the image by 35? projection was better than that of the control group. Conclusion 35? projection results in the images satisfying clinical requirements.
2.A Study of Application of the Computed Radiography on the Radiography of the Whole Lower Limb
Yani BAI ; Hongde HE ; Zhensheng DENG
Journal of Practical Radiology 2001;0(09):-
Objective To investigate the application of computed radiography(CR) in X-ray projection of whole lower limbs.Methods The radiography in the patient with bilateral knee-malformation was performed using 500 mA X-ray apparatus and several imaging plates(IP) jointed together,then the images including whole both sides of lower limbs were obtained by post-proccesing technique.Results The images not only could show the whole lower limbs on a single film,but be intact.The images also could be used for measuring the length of leg,the angle between the axises of the thigh and the magnifying really.Conclusion The image of whole bilateral lower limbs with a good quality and unity can be acquired using CR and post-processing technique appropriately.
3.Clinical effect of propafenone and amiodarone on paroxysmal supraventricular tachycardia
Yuping HAN ; Yani BAI ; Hong LIU
Chinese Journal of Biochemical Pharmaceutics 2016;36(12):91-93
Objective To investigate the comparison of the clinical treatment efficacy of propafenone and amiodarone in patients with paroxysmal supraventricular tachycardia ( PSVT ) .Methods Retrospective a total of 89 patients with PSVT from June 2013 to June 2015 in our hospital were selected.According to the different administration methods, the patients were divided into the propafenone group of 46 cases and the amiodarone group of 43 cases.The changes of left ventricular end-systolic volume, left ventricular end-diastolic volume, ejection fraction, cardioversion success rate, mean cardioversion time, heart rate and side effects were compared.Results After treatment, the left ventricular end-systolic volume (52.31 ±8.34) mL/m2 , (54.28 ±7.23) mL/m2, left ventricular end-diastolic volume (47.31 ±8.56) mL/m2, (45.28 ±7.16) mL/m2 and ejection fraction (61.57 ± 0.76)%, (61.39 ±0.69)% were without significant differences.After treatment, the heart rates of the two groups were significantly decreased, the propafenone group ( 85.31 ±12.84 ) times/min, amiodarone group ( 87.26 ±11.95 ) times/min, and there were not significant differences.The recovery time of propafenone group was ( 19.34 ±4.76 ) , higher than the amiodarone group ( 25.69 ±6.09 ) ( P <0.05 ).But the success rate of cardioversion (52.17%) was lower than the amiodarone group (88.37%) (P<0.05).The side effect rates in the propafenone group (21.74%) was significantly higher than that in the amiodarone group ( 4.65%) ( P <0.05 ) .Conclusion Propafenone and amiodarone cardioversion PSVT have achieved good results, but propafenone rapid onset, the average cardioversion time is short, which is only suitable for acute tachycardia and without serious organic heart disease patients.Amiodarone onset is slower,but the cardioversion success rate is higher.
4.Comparison of acute toxicity of two preparations of norcantharidin in mice
Bai LI ; Lifeng ZHU ; Yani ZHANG ; Wei GU
Journal of Integrative Medicine 2007;5(1):74-7
OBJECTIVE: To compare the acute toxicity of common injection and sustained-release preparation of norcantharidin for mice so as to identify the attenuation of the sustained-release preparation of norcantharidin. METHODS: The poloxamer 407 was used as a sustained-release vehicle for topical administration of norcantharidin, and the acute toxicity of mice treated with common injection and sustained-release preparation of norcantharidin was observed. The median lethal dose (LD(50)) was calculated by Bliss software. RESULTS: The symptoms of mice were similar between the two groups, but the appearance of symptoms in norcantharidin/poloxamer 407 group was 4 hours later than that in norcantharidin group. The LD(50) of norcantharidin administered through vein injection was 12.6 mg/kg. The LD(50) of norcantharidin/poloxamer 407 administered through intraperitoneal injection, intrahepatic injection and intramuscular injection were 19.9, 19.1 and 20.9 mg/kg, respectively, and the LD(50) of the common preparation were 13.0, 13.1 and 15.1 mg/kg, respectively. CONCLUSION: The norcantharidin/poloxamer 407 is less toxic than the equivalent dose of norcantharidin, mainly because norcantharidin/poloxamer 407 may release norcantharidin sustainedly, thus reducing norcantharidin concentration in blood.
5.The Technique of SCTA Image in Aortic Dissection
Xuepeng GONG ; Yi HUAN ; Zhijun YOU ; Yani BAI ; Wei SHI
Journal of Practical Radiology 2001;0(07):-
Objective To study the scan parameter of spiral CT angiography in aortic dissection.Methods 34 cases with aortic dissection successively underwent SCTA were studied retrospectively.The CT scan parameters,methods of posteriorimage treating were reviewed and analysed one by one.Results In 34 cases,32 cases were diagnosed as aortic dissection and classified correctly,in accordance with the result of operation and DSA,the quality of image was satisfied and the rate of success at least above 88.9%.The use of main scan parameters:(1)the ascend aortic dissection:slice thickness 4 mm,reconstruction interval 2 mm,pitch 1.25;tube current 175 mA;(2)involed in ascend,arch,descend and throacic aorta dissection:slice thickness 5 mm,reconstruction interval 2~3 mm,pitch 1.5;tube current 150 mA;(3)involved in abdominal aortic dissection:slice thickness 6~8 mm,reconstruction interval 2~3 mm,pitch 1.5 or 1.75;tube current 125 mA.The tube voltage all were 120 kV,the dosage of contrast media was 90~100 ml;the delayed scan time was choiced 20 second in throacic aortic and 25 second in abdominal aortic.The posterior image methods main used MPR,SSD,MIP and VR. Conclusion To set a sensible scaning plan,choose and match scan parameters properly according to the scaning length,can avoid the shortage of restrain SCTA scaning length and get satisfied image.
6.Safety Evaluation for Interventional Radiotherapy with X-ray Angiography
Yani BAI ; Shu QIAN ; Zifu HE ; Min JIA ; Xiao FAN ; Lei JIN
Chinese Medical Equipment Journal 2003;0(10):-
Objective To evaluate the safety of interventional radiotherapy with X-ray angiography. Methods To compare X-ray radiation levels with and without radioprotect with X-ray protective monitor by simulating operators' body's parts. Results The difference is significant. Conclusion Interventional radiotherapy with angiography with effective protect is safe.
7.New Advance of Digital X-ray Imaging Technique
Houjun YU ; Yani BAI ; Xuexin ZHANG ; Kai LIU ; Ying LIN ; Zhijun YOU
Chinese Medical Equipment Journal 2003;0(10):-
Digital X-ray imaging technique has been developing rapidly in recent years, and makes it possible for people to be radiated by lower X-ray dose than before to get the images for diagnosis. Current development in 7 aspects about digital roentgenography is introduced in this article.
8.Establishment of a multidrug-resistant cell line BEL-7402/5-FU of human hepatocellular carcinoma and its biological characteristics
Wei GU ; Yani ZHANG ; Bai LI ; Jie HAN ; Binbin CHENG ; Changquan LING
Journal of Integrative Medicine 2006;4(3):265-70
OBJECTIVE: To establish a multidrug-resistant cell line BEL-7402/5-FU of hepatocellular carcinoma (HCC). METHODS: BEL-7402/5-FU was induced by pulse therapy combined with continuous stepwise exposure to 5-fluorouracil in vitro. MTT assay was used to determine its multidrug resistance (MDR). Biological characteristics of the BEL-7402/5-FU cell line were observed including morphological changes, cell growth curve, population doubling time, plate cloning efficiency, adherence rate, cell cycle distribution, chromosome and tumorigenicity. Accumulation amount of adriamycin (ADM) in cytoplasm was measured by flow cytometry. The protein expression of thymidylate synthase (TS) was evaluated by immuno-cytochemical method. RESULTS: The acquired MDR cell line of BEL-7402/5-FU was established successfully. The BEL-7402/5-FU cells showed cross-resistance to ADM, vincristine (VCR), methotrexate (MTX) and oxaliplatin (OHP), whereas still sensitive to hydroxycamptothecin (HCPT). The BEL-7402/5-FU cells tended to grow in clusters in vitro. It was found that the population doubling time of BEL-7402/5-FU cells was longer than that of its parental cells. The plate cloning efficiency and the adherence rate of BEL-7402/5-FU cells at the 2nd and 3rd hour were both lower than those of the parental cells. The distributing proportion of BEL-7402/5-FU cells in G(0)/G(1) phase was less than that of the parental cells, whereas the distributing proportion of BEL-7402/5-FU cells in S phase was higher than that of the parental cells. The accumulation amount of ADM in cytoplasm of BEL-7402/5-FU cells was significantly lower while the expression level of TS protein of which was highly up-regulated as compared with those of the parental cells. CONCLUSION: Establishment of the human HCC cell line BEL-7402/5-FU might be beneficial to the studies of 5-Fluorouracil acquired MDR mechanisms and the selection of reversal modifiers.
9.Nitric oxide formation contributes to beta-adrenergic dilation of epicardial coronary arteries in response to intravenous administration of dobutamine in dogs.
Haoyi YANG ; Youbin DENG ; Xiaojun BI ; Qing CHANG ; Jiao BAI ; Min PAN ; Huijuan XIANG ; Hongyun LIU ; Xiulan LI ; Yani LIU ; Chunlei LI
Journal of Huazhong University of Science and Technology (Medical Sciences) 2004;24(2):189-191
To examine the role of nitric oxide in the beta-adrenergic vasodilation of epicardial coronary arteries in dogs, 12 dogs were instrumented for measurement of left anterior descending coronary artery diameter by transthoracic echocardiography before and after dobutamine (5 microg/kg/min IV) with and without intracoronary infusion of NG-monomethyl-L-arginine (L-NMMA) (1 mg/kg). In all 12 dogs, the diameter of left anterior descending coronary artery increased significantly from 2.35 +/- 0.25 mm to 2.59 +/- 0.24 mm (P<0.001) after dobutamine administration. In 6 of the 12 dogs, the percent change in left anterior descending coronary artery diameter induced by dobutamine decreased significantly from 12.5% +/- 8.6% to -1.5% +/- 5.4% (P<0.05) after the administration of intracoronary L-NMMA (1 mg/kg for 5 min) to block nitric oxide synthesis from L-arginine. The study demonstrated that nitric oxide formation contributes to the beta-adrenergic dilatory response of epicardial coronary arteries to dobutamine in dogs.
Adrenergic beta-Agonists
;
pharmacology
;
Animals
;
Coronary Vessels
;
physiology
;
Dobutamine
;
pharmacology
;
Dogs
;
Echocardiography
;
Female
;
Male
;
Nitric Oxide
;
physiology
;
Receptors, Adrenergic, beta
;
physiology
;
Vasodilation
;
physiology
;
omega-N-Methylarginine
;
pharmacology
10.Application of X-ray and MRI in the diagnosis of rotator cuff injury of supraspinatus muscle outlet
Zifu HE ; Feihan JIAO ; Yani BAI ; Chaowei MA
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(6):1027-1031
[Objective] To evaluate the value of X-ray combined with MRI in the diagnosis of rotator cuff injury. [Methods] A retrospective study was conducted on the patients who underwent X-ray and MRI examinations at the First Affiliated Hospital of Air Force Medical University from January 2021 to March 2022. A total of 158 patients were recruited, among whom 146 had rotator cuff injury, 10 had rheumatoid arthritis, and 2 had shoulder joint space occupation. We compared the specificity, sensitivity, consistency, detection rate, missed diagnosis rate and misdiagnosis rate of various examinations, and compared the X-ray and MRI examination results. [Results] The sensitivity and specificity of X-ray for rotator cuff injury were 65.8% and 41.7%, those of MRI for rotator cuff injury were 78.1% and 66.7%, and those of the combined diagnosis were 93.8% and 83.3%, respectively. The Kappa value of the combined diagnosis of rotator cuff injury and surgical results was higher than that of X-ray and MRI diagnosis (P<0.05). The detection rate and missed diagnosis rate of the three groups differed significantly (χ2=6.095, 13.113, P<0.05). The detection rate of rotator cuff injury by the combined diagnosis was higher than that of X-ray and MRI diagnosis, and the missed diagnosis rate was lower than that of the latter (P>0.05). [Conclusion] The detection rate of rotator cuff injury of shoulder joint by the combined examination is higher than that of X-ray and MRI, and the rate of missed diagnosis and misdiagnosis is lower. The combined examination can provide detailed evaluation for preoperative diagnosis.