1.EFFECT OF EXERCISE WITH AN ANKLE DESTABILIZATION DEVICE ON PERONEAL MUSCLES
NANA INOUE ; YUKIO URABE ; YUKI YAMANAKA ; IKUTOSHI ICHIKI ; YUKI NODA
Japanese Journal of Physical Fitness and Sports Medicine 2009;58(5):499-506
Purpose: The aim of the present study was to make an ankle destabilization device and investigate the effect of exercise with this device on peroneal muscles.Methods: Seventeen healthy subjects were instructed to undergo step movement exercise with the lower extremity 150 times on the spot using the ankle destabilization device. Before and after stepping, the reaction time and mean frequency of the peroneus longus and the peroneus brevis muscles were compared. While stepping with the device, muscular activity of the peroneus longus and the peroneus brevis was compared under both stable and instable conditions.Result: The results showed that peroneal reaction time didn't change after stepping with the device; but the frequency of peroneal muscle activity increased after stepping. While stepping, muscular activity of the peroneal muscles increased in an instable condition.Conclusion: The results suggested that stepping exercise with the device could be beneficial for peroneal muscles.
2.Relationships between throwing injuries and functional movement screen in junior high school baseball players
Tomoya Uchida ; Shintaro Matsumoto ; Minoru Komatsu ; Yuki Noda ; Miya Ishida ; Michiru Tsukuda ; Ryota Nakayama ; Yuta Takeda ; Rieko Hirakawa ; Kohei Muto ; Satoshi Okubo ; Hiroyuki Furukawa ; Kenji Fujita
Japanese Journal of Physical Fitness and Sports Medicine 2016;65(2):237-242
Recently, the problem of the high incidence of throwing injuries in young people has been gaining attention. Identifying high-risk players before the onset of the throwing injury is important for prevention. One of the most widely used screening tests for sports-related injuries is the Functional Movement Screen (FMS), which assesses the quality of movement; however, its correlation with throwing injuries has not been established. The purpose of this study was to investigate the correlation between the FMS score and throwing injuries. The FMS was used during the medical check for two hundred and thirty junior high school baseball players. We allotted those who had experienced throwing injuries multiple times to the injury group and those who had never experienced throwing injury to the control group. We then calculated the FMS cutoff value using the receiver operating characteristic curve. In addition, we investigated differences in the incidence of throwing injury between above and below the cutoff value using chi-square test. The FMS cutoff score was 17. Players who scored ≤17 had a significantly higher incidence of throwing injuries than those who scored ≥18. Conclusion: We believe that FMS score is correlated to throwing injuries. In addition, the results suggest that throwing injuries might be prevented in junior high school baseball players who scored ≤17 on the FMS if they undergo training in the correct movement patterns.
3.Endoscopic Ultrasonography-Guided Gallbladder Drainage as a Treatment Option for Acute Cholecystitis after Metal Stent Placement in Malignant Biliary Strictures
Fumisato KOZAKAI ; Yoshihide KANNO ; Kei ITO ; Shinsuke KOSHITA ; Takahisa OGAWA ; Hiroaki KUSUNOSE ; Kaori MASU ; Toshitaka SAKAI ; Toji MURABAYASHI ; Keisuke YONAMINE ; Yujiro KAWAKAMI ; Yuki FUJII ; Kazuaki MIYAMOTO ; Yutaka NODA
Clinical Endoscopy 2019;52(3):262-268
BACKGROUND/AIMS: It is often difficult to manage acute cholecystitis after metal stent (MS) placement in unresectable malignant biliary strictures. The aim of this study was to evaluate the feasibility of endoscopic ultrasonography-guided gallbladder drainage (EUS-GBD) for acute cholecystitis. METHODS: The clinical outcomes of 10 patients who underwent EUS-GBD for acute cholecystitis after MS placement between January 2011 and August 2018 were retrospectively evaluated. The procedural outcomes of percutaneous transhepatic gallbladder drainage (PTGBD) with tube placement (n=11 cases) and aspiration (PTGBA) (n=27 cases) during the study period were evaluated as a reference. RESULTS: The technical success and clinical effectiveness rates of EUS-GBD were 90% (9/10) and 89% (8/9), respectively. Severe bile leakage that required surgical treatment occurred in one case. Acute cholecystitis recurred after stent dislocation in 38% (3/8) of the cases. Both PTGBD and PTGBA were technically successful in all cases without severe adverse events and clinically effective in 91% and 63% of the cases, respectively. CONCLUSIONS: EUS-GBD after MS placement was a feasible option for treating acute cholecystitis. However, it was a rescue technique following the established percutaneous intervention in the current setting because of the immature technical methodology, including dedicated devices, which need further development.
Bile
;
Cholecystitis, Acute
;
Constriction, Pathologic
;
Dislocations
;
Drainage
;
Gallbladder
;
Humans
;
Retrospective Studies
;
Stents
;
Treatment Outcome
4.Capability of Radial- and Convex-Arrayed Echoendoscopes for Visualization of the Pancreatobiliary Junction.
Yoshihide KANNO ; Kei ITO ; Shinsuke KOSHITA ; Takahisa OGAWA ; Hiroaki KUSUNOSE ; Kaori MASU ; Toshitaka SAKAI ; Toji MURABAYASHI ; Sho HASEGAWA ; Fumisato KOZAKAI ; Yujiro KAWAKAMI ; Yuki FUJII ; Yutaka NODA
Clinical Endoscopy 2018;51(3):274-278
BACKGROUND/AIMS: Although both radial- and convex-arrayed endoscopic ultrasonography (EUS) scopes are widely used for observational EUS examinations, there have been few comparative studies on their power of visualization. The aim of this study was to evaluate the capability of these EUS scopes for observation of the pancreatobiliary junction. METHODS: The rate of successful visualization of the pancreatobiliary junction was retrospectively compared between a radial-arrayed and a convex-arrayed echoendoscope, from a prospectively maintained database. Study periods were defined as January 2010 to December 2012 for the radial group, and February 2015 to October 2016 for the convex group because the respective scope was mainly used during those periods. RESULTS: During the study period, 1,660 cases with radial EUS and 1,984 cases with convex EUS were recruited. The success rates of observation of the pancreatobiliary junction were 80.0% and 89.5%, respectively (p < 0.0001). CONCLUSIONS: The capability of visualization of the pancreatobiliary junction in observational EUS was found to be better with a convex-arrayed than with a radial-arrayed echoendoscope.
Endosonography
;
Prospective Studies
;
Retrospective Studies
5.Predictive Factors for Inaccurate Diagnosis of Swollen Lymph Nodes in Endoscopic Ultrasound-Guided Fine Needle Aspiration
Yuki FUJII ; Yoshihide KANNO ; Shinsuke KOSHITA ; Takahisa OGAWA ; Hiroaki KUSUNOSE ; Kaori MASU ; Toshitaka SAKAI ; Keisuke YONAMINE ; Yujiro KAWAKAMI ; Toji MURABAYASHI ; Fumisato KOZAKAI ; Yutaka NODA ; Hiroyuki OKADA ; Kei ITO
Clinical Endoscopy 2019;52(2):152-158
BACKGROUND/AIMS: This study aimed to identify the predictive factors for inaccurate endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) diagnosis of swollen lymph nodes without rapid on-site cytopathological evaluation. METHODS: Eighty-three consecutive patients who underwent EUS-FNA for abdominal or mediastinal lymph nodes from January 2008 to June 2017 were included from a prospectively maintained EUS-FNA database and retrospectively reviewed. The sensitivity, specificity, and accuracy of EUS-FNA for the detection of neoplastic diseases were calculated. Candidate factors for inaccurate diagnosis (lymph node size and location, needle type, puncture route, number of passes, and causative disease) were evaluated by comparison between accurately diagnosed cases and others. RESULTS: The final diagnosis of the punctured lymph node was classified as neoplastic (65 cases: a metastatic lymph node, malignant lymphoma, or Crow-Fukase syndrome) or non-neoplastic (18 cases: a reactive node or amyloidosis). The sensitivity, specificity, and accuracy were 83%, 94%, and 86%, respectively. On multivariate analyses, small size of the lymph node was the sole predictive factor for inaccurate EUS-FNA diagnosis with a significant difference (odds ratios, 19.8; 95% confidence intervals, 3.15–124; p=0.0015). CONCLUSIONS: The lymph node size of <16 mm was the only independent factor associated with inaccurate EUS-FNA diagnosis of swollen lymph nodes.
Diagnosis
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration
;
Endosonography
;
Humans
;
Lymph Nodes
;
Lymphatic Diseases
;
Lymphoma
;
Multivariate Analysis
;
Needles
;
Prospective Studies
;
Punctures
;
Retrospective Studies
;
Risk Factors
;
Sensitivity and Specificity
6.Predictive Value of Localized Stenosis of the Main Pancreatic Duct for Early Detection of Pancreatic Cancer
Yoshihide KANNO ; Shinsuke KOSHITA ; Takahisa OGAWA ; Hiroaki KUSUNOSE ; Kaori MASU ; Toshitaka SAKAI ; Keisuke YONAMINE ; Yujiro KAWAKAMI ; Yuki FUJII ; Kazuaki MIYAMOTO ; Toji MURABAYASHI ; Fumisato KOZAKAI ; Jun HORAGUCHI ; Yutaka NODA ; Masaya OIKAWA ; Takaho OKADA ; Kei ITO
Clinical Endoscopy 2019;52(6):588-597
BACKGROUND/AIMS: In this study, we aimed to evaluate the predictive value of localized stenosis of the main pancreatic duct (MPD) for early detection of pancreatic cancer.METHODS: Among 689 patients who underwent endoscopic retrograde pancreatography from January 2008 to September 2018, 19 patients with MPD findings were enrolled. These patients showed findings for indicating suspicious pancreatic cancer at an early stage (FiCE); FiCE was defined as a single, localized stenosis in the MPD without a detectable mass (using any other imaging methods) and without other pancreatic diseases, such as definite chronic pancreatitis, intraductal papillary mucinous neoplasm, and autoimmune pancreatitis. Final diagnoses were established by examining resected specimens or through follow-up examinations after an interval of >5 years.RESULTS: Among 19 patients with FiCE, 11 underwent surgical resection and 8 were evaluated after a >5-year observation period. The final diagnosis of the MPD stenosis was judged to be pancreatic cancer in 9 patients (47%), including 3 with intraepithelial cancer, and to be a non-neoplastic change in 10. The sensitivity, specificity, and accuracy of preoperative pancreatic juice cytology were 75%, 100%, and 88%, respectively.CONCLUSIONS: The predictive value of FiCE for pancreatic cancer prevalence was 47%. Histological confirmation with pancreatic juice cytology is necessary before surgical resection.
Cholangiopancreatography, Endoscopic Retrograde
;
Constriction, Pathologic
;
Diagnosis
;
Follow-Up Studies
;
Humans
;
Mucins
;
Pancreatic Diseases
;
Pancreatic Ducts
;
Pancreatic Juice
;
Pancreatic Neoplasms
;
Pancreatitis
;
Pancreatitis, Chronic
;
Prevalence
;
Sensitivity and Specificity