1.Aortic Root Imaging and Clinical Application in 15 Patients With Transcatheter Aortic Valve Implantation--A Single Center Early Experience
Moyang WANG ; Liang XU ; Hanjun PEI ; Siyong TENG ; Haitao ZHANG ; Bin LV ; Hao WANG ; Yuejin YANG ; Yongjian WU
Chinese Circulation Journal 2014;(9):714-717
Objective: To study the aortic root imaging and clinical application in 15 patients with transcatheter aortic valve implantation (TAVI).
Methods: A total of 15 patients with severe aortic valve stenosis received TAVI in our hospital from 2011-03 to 2013-11 were studied. The CT scan and transthoracic echocardiography were conducted to measure the aortic root anatomy and the differences of annulus size between CT and echocardiography were calculated. The prosthetic valves were selected based on CT measurement. The pre-operative accuracy of measurement was evaluated by the follow-up study at 6 months after operation.
Results: The CT measured pre-operative aortic annulus short diameter was (21.5 ± 2.4) mm, long diameter was (27.3 ± 2.7) mm, the average inner diameter was (24.4 ± 2.4) mm, left ventricular out lfow (LVOF) tract long diameter was (28.3 ± 4.5) mm, the average inner diameter of LVOF was (24 ± 3.5), ascending aorta diameter was (35.3 ± 4.4) mm. The Venus Medtech A-Valve implanted in 8 patients with #26 and in 7 patients with #29. The average inner diameter of aortic annulus measured by CT was larger than transthoracic echocardiography, P<0.001. During 6 months follow-up period, no patients had aortic root rupture, coronary obstruction, moderate and severer aortic and peri-aortic regurgitation. There were 4 patients with atrio-ventricular block and received permanent pacemaker implantation.
Conclusion: There is a difference for aortic annulus size by CT and transthoracic echocardiography measurements. CT may presisely assess the aortic root morphology and provide strong support for TAVI.
2. Impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement in patients with native bicuspid aortic valve stenosis
Moyang WANG ; Guangyuan SONG ; Yuan WANG ; Guannan NIU ; Qian ZHANG ; Zheng ZHOU ; Hao ZHANG ; Wenjia ZHANG ; Tong LUO ; Siyong TENG ; Yuejin YANG ; Yongjian WU
Chinese Journal of Cardiology 2018;46(8):629-634
Objective:
To investigate the impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement (TAVR) in bicuspid aortic valve patients.
Methods:
Clinical data of 40 patients with native bicuspid aortic valve stenosis who underwent TAVR using the self-expandable prosthesis (the Venus A-valve) from 2014 to 2017 in Fuwai Hospital was retrospectively analyzed. The patients were divided into non-deep implantation group (implant depth ≤10 mm by instant angiogram after implantation,29 cases) and deep implantation group (implant depth> 10 mm by instant angiogram after implantation,11 cases).Pre-procedural aortic root characteristics (e.g. calcification, angle and dimensions) were assessed by CT. The impact of aortic root morphology on the implantation depth and clinical outcomes were also evaluated.
Results:
The age was (75.1±5.9) years with equal representation from the raphe-type and non-raphe type (52.5%(21/40) and 47.5%(19/40)).The bigger aorta angle ((56.5±4.5)° vs. (47.4±9.4)°,
3.Effect and molecular mechanism of isorhamnetin extracted from Ginkgo biloba on the differentiation of RAW264.7 cells into osteoclasts
LI Jing ; CHENG Liang ; GUO Lü ; hua ; LI Tong ; YANG Moyang ; WANG Junmei ; WU Zhe
Journal of Prevention and Treatment for Stomatological Diseases 2018;26(3):158-165
Objective :
To investigate the effect and potential molecular mechanisms of isorhamnetin (ISO) extracted from Ginkgo biloba on the differentiation of osteoclasts.
Methods:
Osteoclast precursor RAW264.7 cells were induced with RANKL to differentiate into mature osteoclasts. Different concentrations of ISO were added to RAW264.7 cells to determine its effect on osteoclast differentiation. CCK8 was used to evaluate the effect of ISO on cytotoxicity. The impact of ISO on the osteoclast differentiation process was investigated by analyzing tartrate resistance and bone resorption lacuna. Real-time PCR was performed to analyze the levels of differentiation marker genes, including tartrate resistant acid phosphatase (Trap), cathepsin K (Ctsk), and matrix metalloproteinase 9 (MMP-9); differentiation-related transcription factors, including the proto-oncogene protein c-Fos, nuclear factor of activated T-cells cytoplasmic 1(NFATc1); and the levels of downstream NF-κB p65 signaling pathway phosphorylation. Using the above-described method, we verified that ISO exerted an inhibitory effect on osteoclast differentiation and explored related molecular mechanisms.
Results :
Different concentrations of ISO (1-10 μM) had no cytotoxic effects on RAW264.7 cells, inhibited TRAP activity and decreased the number of bone resorption lacuna during osteoclast differentiation. When applied at a concentration of 10 μM, its inhibitory effect was significant. In addition, ISO significantly reduced the expression levels of Trap, Ctsk, MMP-9, c-Fos, NFATc1 and NF-κB p65 mRNA.
Conclusion
ISO extracted from Ginkgo biloba extract exerted an inhibitory effect on osteoclast differentiation, and the mechanism underlying its activity may involve the inhibition of the classical NF-κB pathway.
4.The First Application of Domestically Produced Self-expanding Transcatheter Aortic Valve Controllable Bending Delivery System in China
Yang CHEN ; Guoliang CHEN ; Di SONG ; Hongliang ZHANG ; Moyang WANG ; Guannan NIU ; Zheng ZHOU ; Qian ZHANG ; Qingrong LIU ; Zhenyan ZHAO ; Jie ZHAO ; Bin ZHANG ; Dejing FENG ; Wence SHI ; Jicheng XI ; Yongjian WU
Chinese Circulation Journal 2024;39(3):285-289
A domestically produced self-expanding transcatheter aortic valve controllable bending delivery system(VitaFlow? Ⅲcontrollable bending retrievable delivery system)was first used to perform transcatheter aortic valve replacement(TAVR)in a symptomatic severe aortic valve stenosis patient with severe heart failure and high risk of surgery in China on September 22,2023.The patient successfully completed TAVR under general anesthesia,with good valve position and function after the operation.Before discharge and at one month of follow-up,the patient's symptoms and degree of heart failure were significantly improved.The follow-up results of this case showed that the VitaFlow? Ⅲ controllable bending retrievable delivery system for TAVR is safe and feasible,and future prospective,multicenter clinical trials are expected to evaluate its efficacy.