1.Cleaning and Sterilization of Rent Instruments in Hospitals:A Discussion
Liming QIAN ; Xuehui WANG ; Xiaoning WANG ; Qianjian QIAN
Chinese Journal of Nosocomiology 2009;0(17):-
OBJECTIVE To control the quality of cleaning and sterilization of rent instruments and to secure medical safety of patients undergoing operations.METHODS We randomly chose 60 pieces of rent instruments and divided them into two groups,machinery wash group and hand wash group.Occult blood test was performed before and after washing and rinsing.RESULTS Positive rate of occult blood tests was 86.67% before either machinery or hand wash.While after machinery wash and hand wash it was 0% and 6.67%,respectively.Both wash methods had significant effect on depleting occult blood(P0.05).CONCLUSIONS Hospitals must enhance the management of rent instruments cleaning which is of poor quality at present by regulating the procedure and monitoring methods so as to ensure the quality of rent instruments cleaning and secure patients safety.
2.The research in the effect of early systemic nursing intervention on the lime of indwelling urethral catheter after surgery of uterine cervix cancer
Rui HONG ; Lianzhi HE ; Wen FANG ; Xiao WU ; Xuehui QIAN ; Qinghua WANG
Chinese Journal of Practical Nursing 2009;25(5):15-18
Objective Through early systemic nursing intervention of cervical cancer patients for promotion of the recovery of urinary bladder function, to remove the urethral catheter in advance,and reduce the occurrence of urinary bladder dysfunction. Methods 80 cervical cancer patients after total hysterectomy were divided into the treatment group and the control group with 40 cases in each group stochastically. The treatment group was given systemic nursing( psychological nursing,pelvis bottom muscles exercising,urination discontinuance exercising,abdominal muscle exercising,Valsalva maneuver exercising, Crede press exercising,open the urethral catheter timely and individually,cheiropractic with hot roller), the control group received conventional nursing and some simple training of urinary bladder function. The time of indwelling urethral catheter after the hysterectomy was compared. Results The time of indwelling urethral catheter in the treatment group and in the control group were (9.65±49)days and (15.88±03)days respectively. The incidence rate of residual urine,urine retention and infection of urinary system after surgery in the treatment group was lower than that of the control group. Conclusions Early systemic nursing intervention can shorten the time of indwelling urethral catheter after hysterectomy, reduce the occurrence of urinary bladder dysfunction .improve the surgery effect for the cervical cancer patients and ameliorate their quality of life.
3.The performance evaluation of four Lp-PLA2 activity assays
Danchen WANG ; Li'an HOU ; Ling QIU ; Xiuzhi GUO ; Liangyu XIA ; Qiong WU ; Yi'cong YIN ; Honglei LI ; Dandan LI ; Qian LIU ; Xuehui GAO ; Liyan LIN
Chinese Journal of Laboratory Medicine 2018;41(3):208-213
Objective To evaluate the analytical performance of four lipoprotein associated phospholipase A2(Lp-PLA2)activity reagents on Beckman AU5800 automatic biochemical analyzer. Methods The remaining serum samples of 214 patients and 140 apparently healthy individuals were collected from March to July 2017 in Peking Union Medical College Hospital.These samples were used for method comparison and reference interval evaluation.According to the guidelines of EP15-A,EP6-A,EP-17 and EP7-P from Clinical and Laboratory Standards Institute(CLSI)standards,the precision, linearity, sensitivity and common interferences(e.g free bilirubin, conjunct bilirubin, hemoglobin and chyle)were assessed.According to EP9-A2,method comparisons of differents regents(Evermed,DiaSys,Hengxiao and Zhongyuan were labeled as A,B,C and D,respectively)were conducted and the differences were estimated at medical decision levels(328U/L,391U/L and 485U/L).Results The precision of four reagents were acceptable.The repeatability(CV%)of A to D were 0.5%-1.7%, 0.7%-3.0%, 0.9%-2.0% and 0.5%-3.3%,respectively.The reproducibility(CV%)were 0.7%-2.9%, 1.4%-3.2%, 1.3%-1.9%and 0.8%-4.1%,respectively.Both of those achievedlaboratory defined quality objective(<5%).The linearity of A to D were 44 -1 992 U/L,39 -1 798 U/L,13 -540 U/L and 75-1 717U/L,respectively.The regression coefficient R2 was between 0.997 and 1.000, and the correlation coefficient(r)was between 0.998 and 1.000.The interference of chyle were acceptable among these four reagents andmet the manufacturer′s requirementsor clinical needs.In a low level of Lp-PLA2,bilirubin had an obvious interferenceonreagent C;B and C were negatively affected when the hemoglobin was 4.5 g/L; and D was positively affected when the hemoglobin was 2.45 g/L.The regression coefficients R2 of A,C,D compared with B were between 0.978 and 0.995,and the correlation coefficients(r)were between 0.989 and 0.998. The expected differences at medical decision levels ranged from -240 U/L to 113 U/L.For A to D,the Lp-PLA2 activity results of 131(93.6%), 140(100%), 82(58.6%), and 128(91.4%)cases were analysed within the manufacturer′s claimed reference intervals.Conclusion The precision and linearity of the four Lp-PLA2 activity detection reagents used in automatic biochemical analyzer are good, but the anti-interference ability needs to be improved.
4.Construction and biological characterization of lmo2363 gene deletion strain of Listeria monocytogenes
Ji ZHI ; Qing CAO ; Xuehui ZHAO ; Haohao ZHANG ; Ziqiu FAN ; Yonghui MA ; Jing DENG ; Zengwen HE ; Jinrui MA ; Kunzhong ZHANG ; Qian CHONG ; Caixia WANG ; Huiwen XUE ; Huitian GOU
Chinese Journal of Veterinary Science 2024;44(9):1923-1929,1956
This study aims to investigate the function of lmo2363 gene in stress resistance of Liste-ria monocytogenes strain LM83-1.In this study,the lmo2363 gene deletion strain and complement-ation strain of Listeria monocytogenes were constructed using overlapping extended PCR and ho-mologous recombination techniques,and the growth ability,stress survival rate and biofilm forma-tion ability of wild,deletion strain and complementation strain were compared under different stress environments.lmo2363 gene deletion strain and complementation strain of Listeria monocy-togenes were successfully constructed in this experiment.The growth curves showed that the growth capacity of the deletion strain was weaker than the wild strain LM83-1 under 4 ℃,7%NaCl,10%NaCl,3.5%ethanol,4.0%ethanol and pH5 stress(P<0.001).The results of stress survival test showed that the survival rate of the deletion strain was significantly lower than the wild strain after 1 h treatment with pH3 and 10 mmol/L H2 O2 stress(P<0.010).The biofilm forming ability of the deletion strain was decreased compared with that of the wild strain(P<0.050).This study confirmed that lmo2363 gene mediated the adaptation of LM to low temperature,high osmotic pressure,ethanol and acid stress environment and affected the formation of LM bio-film.This study laid a foundation for further exploring the function of lmo2363 gene in the stress resistance process of Listeria monocytogenes.
5.Early clinical and CT features of COVID-19 and community-acquired pneumonia from a fever observation ward in Ningbo, China.
Guoqing QIAN ; Yuanwei LIN ; Xueqin CHEN ; Ada Hoi Yan MA ; Xuehui ZHANG ; Guoxiang LI ; Xinzhong RUAN ; Liemin RUAN
Singapore medical journal 2022;63(4):219-224
INTRODUCTION:
We aimed to compare the early clinical manifestations, laboratory results and chest computed tomography (CT) images of COVID-19 patients with those of other community-acquired pneumonia (CAP) patients to differentiate CAP from COVID-19 before reverse transcription-polymerase chain reaction results are obtained.
METHODS:
The clinical and laboratory data and chest CT images of 51 patients were assessed in a fever observation ward for evidence of COVID-19 between January and February 2020.
RESULTS:
24 patients had laboratory-confirmed COVID-19, whereas 27 individuals had negative results. No statistical difference in clinical features was found between COVID-19 and CAP patients, except for diarrhoea. There was a significant difference in lymphocyte and eosinophil counts between COVID-19 and CAP patients. In total, 22 (91.67%) COVID-19 patients had bilateral involvement and multiple lesions according to their lung CT images; the left lower lobe (87.50%) and right lower lobe (95.83%) were affected most often, and all lesions were located in the peripheral zones of the lung. The most common CT feature of COVID-19 was ground-glass opacity, found in 95.83% of patients, compared to 66.67% of CAP patients.
CONCLUSION
Diarrhoea, lymphocyte counts, eosinophil counts and CT findings (e.g. ground-glass opacity) could help to distinguish COVID-19 from CAP at an early stage of infection, based on findings from our fever observation ward.
COVID-19/diagnostic imaging*
;
China
;
Community-Acquired Infections/diagnostic imaging*
;
Diarrhea/pathology*
;
Fever
;
Humans
;
Lung/diagnostic imaging*
;
Retrospective Studies
;
SARS-CoV-2
;
Tomography, X-Ray Computed/methods*
6.Efficacy and safety of antibody-drug conjugates in the treatment of breast cancer:a meta-analysis
Yinxue XU ; Lei ZHANG ; Xiwen QIAO ; Xiaolan SHEN ; Qian SHEN ; Xuehui ZHANG
China Pharmacy 2023;34(20):2540-2544
OBJECTIVE To evaluate the efficacy and safety of antibody-drug conjugates (ADC) in the treatment of breast cancer, so as to provide an evidence-based reference for clinical medication. METHODS Retrieved from CNKI, Wanfang database, VIP, PubMed, the Cochrane Library, Embase, and Web of Science, randomized controlled trials (RCTs) about trastuzumab emtansine, trastuzumab deruxtecan and sacituzumab govitecan (trial group) versus chemotherapy or other anti-tumor drugs (control group), were collected during the inception to April 2023. After screening the literature, extracting data, and evaluating the quality of the literature, a meta-analysis was conducted by using RevMan 5.4.1 software. RESULTS A total of 8 RCTs were included, with a total of 5 577 patients. The results of the meta-analysis showed that the progression-free survival (PFS) [HR=0.76, 95%CI (0.69, 0.83), P<0.000 01], overall survival (OS) [HR=0.87, 95%CI (0.81, 0.93), P<0.000 1], and clinical benefit rate (CBR) [OR=2.70, 95%CI (1.15, 6.33), P=0.02] of the trial group were significantly higher than control group. There was no statistically significant difference in objective response rate (ORR) between the two groups [OR=2.34, 95%CI (0.59, 9.33), P=0.23]. The results of subgroup analysis showed that the PFS of HER2-positive patients and HER2-negative patients, and the OS of HER2-positive patients in the trial group were significantly higher than control group (P<0.05). The incidence of anemia and increase of aspartic acid transaminase (AST) in the trial group was significantly higher than control group (P<0.05). The results of sensitivity analysis showed that the results obtained with PFS, OS, and ORR as indicators were relatively robust, while the results obtained with CBR as indicators lacked robustness. CONCLUSIONS ADC drugs have significant effects on breast cancer, but will increase the risk of anemia and elevated AST.
7.Consistency evaluation of thyroid stimulating hormone results from 4 chemiluminescence assays
Danchen WANG ; Songlin YU ; Yicong YIN ; Xiuzhi GUO ; Xinqi CHENG ; Ling QIU ; Chaochao MA ; Ruili ZHANG ; Qian LIU ; Li LIU ; Xuehui GAO ; Kui ZHANG
Chinese Journal of Clinical Laboratory Science 2019;37(1):62-66
Objective:
To compare the consistency of thyroid stimulating hormone (TSH) results from four chemiluminescence assays.
Methods:
A total of 102 fresh serum samples from Peking Union Medical College Hospital during March 2018 and April 2018 were collected for precision evaluation and methodological comparison referring to CLSI EP15-A2 and EP9-A2 protocols. The levels of serum TSH were detected by Abbott i2000 (system A), Beckman DXI800 (system B), Siemens ADVIA Centaur XP (system C) and Roche e601 (system D) automatic chemiluminescence analyzers and their matching reagents, respectively. The obtained results were compared with the passing-bablok and Bland Altman methods. Taking 0.27 μIU/mL and 5.33 μIU/mL as the medical decision level, the expected bias of each detection system was compared.
Results:
The precisions of systems A,B,C and D were 1.7%-3.3%, 2.3%- 3.9%,0.7%-2.3% and 0.6%-1.5%,respectively. The median (P 25,P 75) of TSH concentrations detected by systems A,B,C and D were 1.898 (0.518,4.809)μIU/mL, 2.819 (0.719,7.020)μIU/mL,2.502 (0.692,6.888)μIU/mL and 3.105 (0.886, 7.905)μIU/mL, respectively. The coefficients of determination (R 2 ) of regression equation were above 0.975 for 4 detection systems. The correlation coefficients (r), intercepts and slopes of 4 detection systems were 0.993 5-0.997 1, 0-0.06 and 0.59-1.15, respectively, and systems B and C had the best correlations with 1.02 of slope and 0 of intercept. The deviation plot showed that the bias% of 4 detection systems was between -48.1% and 17.3%. Among them, systems A and D had the largest bias, while systems B and C had the lowest bias. The expected bias of 4 detection systems at the medical decision level was -40.7%-37.2%.
Conclusion
The consistency between Beckman and Siemens TSH detection systems is good, while those of Roche and Abbott TSH detection systems are different from the other two.