1.A biomechanical comparison of parallel plating and vertical plating for humeral intercondylar comminuted fractures
Chinese Journal of Orthopaedic Trauma 2012;14(1):58-60
Objective To compare biomechanical performances of parallel plate fixation and vertical plate fixation for better clinical treatment of humeral intercondylar comminuted fractures (HICF).Methods Models of T-shaped fracture were created using an osteotome at the distal end of humerus in 6 specimens of upper limb in 3 human adult cadavers.The 2 fracture models of left and right humeri in the same cadaver were respectively fixated with parallel plating and vertical plating.On a biomaterial-testing machine,a vertical load was applied onto the fixated distal humerus at a speed of 5 N/s till it reached 2000 N.The loading was repeated 3 times.Vertical compression displacement,intercondylar separating displacement,deformation of medial and lateral condyles and vertical compression stiffness were documented for statistic analyses. Results Under the same load,parallel plating led to significantly less compression displacement,separating displacement and deformation of condyles( P < 0.05) but significantly greater axial compression stiffness( P < 0.05) than vertical plating. Conclusion In biomechanics,parallel plate fixation has better performance than vertical plate fixation for HICF.
2.Reticulocyte parameters of normal human and its relationship with mature erythrocyte parameters
International Journal of Laboratory Medicine 2016;37(8):1049-1051,1054
Objective To investigate the relationship between the parameters of the red blood cells and the corresponding param‐eters of mature red blood cells .Methods Blood samples of 112 healthy males and 110 healthy females were tested for these reticu‐locyte parameters by using Siemens Advia2120 hematology analyzer .Reference intervals were established .Comparisons between these reticulocyte parameters and the corresponding parameters of mature erythrocytes were drawn .Results Reference intervals for the healthy group recruited in this study were determined as follows .Females ,percentage of reticulocyte (Retic% ):0 .45% ~1 .76% ,absolute reticulocyte number(Retic#):(22~86)× 109/L ,mean corpuscular hemoglobin content of reticulocyte(CHr):30 . 1~36 .4 pg ,mean corpuscular volume of reticulocyte(MCVr):99 .5~113 .7 fL .Male ,Retic% :0 .54% ~1 .93% ,Retic# :(29~104)× 109/L ,CHr :32 .6~36 .6 pg ,MCVr :97 .6~112 .7 fL .The absolute reticulocyte of male is significantly higher than that of female;MCVr was significantly larger than mean corpuscular volume of mature erythrocytes ,which was also slightly larger in male than that in female;CHr was significantly higher than mean corpuscular hemoglobin of mature erythrocytes while mean corpuscular hemoglobin concentration of large reticulocytes was lower than that of mature erythrocytes;red blood cell volume distribution width of reticulocytes was lower than that of mature erythrocytes;the hemoglobin content distribution width of mature erythrocytes has a higher uniformity compared with reticulocytes .Conclusion The reference ranges of not commonly used parameters of reticulocytes were established ,and were compared with the corresponding parameters of red blood cells .
3.Research of Electronic Sphygmomanometer Intelligent Aeration Based on Pulse Wave Identification.
Xu ZHANG ; Xuedong SONG ; Jiajun GU ; Jilun YE ; Siping CHEN
Chinese Journal of Medical Instrumentation 2015;39(2):90-94
Through various common domestic and foreign electronic sphygmomanometers to test blood pressure, we find that when measuring high blood pressure or low blood pressure, there is a mismatch between the maximum inflation pressure and the blood pressure measurement, which often results in repeatedly inflating and deflating as well as the problem of high inflation pressure. In order to solve these problems and find a suitable maximum inflation pressure, two intelligent pneumatic solutions based on identifying of pulse wave are suggested and 700 groups of blood pressure experiments are done, then the two solutions are verified by experiments. The experiment proved that these solutions proposed have good stability and accuracy, they can solve the problems appeared in measuring blood pressure effectively, at the same time, the second solution that estimate the maximum inflation pressure during inflation is considered as the best one.
Blood Pressure
;
Blood Pressure Determination
;
instrumentation
;
Heart Rate
;
Humans
;
Hypertension
;
Sphygmomanometers
4.Design of phacoemulsification handpiece and ANSYS finite element optimization analysis
Yuan XIAO ; Yanqun WANG ; Xuedong SONG ; Jun YANG
International Journal of Biomedical Engineering 2013;(2):103-107,115
Objective To design phacoemulsification handpiece with small size and high amplitude amplification coefficient.Methods By introducing the electro-mechanical vibration characteristics of piezoelectric transducer and ultrasonic horn,and adopting the equivalent circuit method and analytical method,respectively,the size of the ultrasonic horn,quarter wavelength piezoelectric transducer and ultrasonic horn were designed.Then,modal and harmonic analysis in finite element analysis software ANSYS11.0 were used to simulate the handpiece,and to optimize the size of the handpiece after adding on needle.Results The results indicated that the longitudinal vibration frequency and amplification coefficient were very close to theoretical design.The errors were 1.4% and 5.8%,respectively.When piezoelectric ceramics were loaded with 300 V sinusoidal voltage,the displacement amplitude at the end of the needle reached 125.5 μm,which could meet the phacoemulsification surgery needs.Conclusion This design greatly reduced the size of the handpiece,and obtained high amplitude amplification coefficient.The simulation results sufficiently validated the theoretical design.
5.Establishment of the management model of chronic obstructive pulmonary disease patients in the Gumei community based on internet of things
Weigang WANG ; Xinping WEI ; Xuedong MA ; Pengyu HUANG ; Yuanlin SONG
Fudan University Journal of Medical Sciences 2017;44(3):344-347
Objective On the basis of internet of things technology,to initially establish a management model of chronic obstructive pulmonary disease (COPD) patients in Gumei community,so as to provide experience for the comprehensive management of community COPD patients.Methods According to the characteristics of the Internet of things technology,we formulated a scheme as a technical route to manage the COPD patients.A homogenous COPD management team of doctors was established under the training of experts from the Department of Respiration of Zhongshan Hospital,Fudan University.Results We drew a COPD patient management model chart,and initially formed a qualified and homogeneous COPD management team of general practitioner.Conclusions Through the Internet of things technology management,we initially formed a set of manual quality control model in the process of data automatic transmission,and initially formed a management model of community COPD patients,based on the internet of things.
6.The research of skin imaging technology with high frequency ultrasound.
Jun YANG ; Jianjun JI ; Yuejie LI ; Yanqun WANG ; Yawei LIU ; Yunhong JI ; Xuedong SONG
Chinese Journal of Medical Instrumentation 2013;37(6):398-400
OBJECTIVEDeveloping a high-frequency ultrasonic skin imaging system to obtain the high resolution ultrasonic image of the skin. And further analyzing the ultrasonic images of skin to explore the imaging characteristics of skin structure and then explore the value of high-frequency imaging in the application of skin diagnosis.
METHODS50 MHz single element ultrasonic transducer, mechanic linear scanning method is used in the imaging system. The resolution and the ability of recognize the skin issue is verified by linear target scanning and clinical trials.
RESULTSBoth the axial and lateral resolution of the system reaches 50 microm. The subtle structure of normal skin tissue is clearly visible. Some diseases have obvious appearance in the image.
CONCLUSIONS50 MHz ultrasonic skin imaging system is of high resolution and is valuable to skin structure detect and disease diagnosis.
Humans ; Skin ; diagnostic imaging ; Ultrasonography ; methods
7.Accurate and rapid detecting β thalassemia by denaturing high-performance liquid chromatography
Song ZHANG ; Yi WU ; Hanliang ZOU ; Qiong WANG ; Yi ZHAO ; Pingan ZHU ; Xuedong LU
Chinese Journal of Laboratory Medicine 2008;31(8):887-889
Objective To evaluate the application value of denaturing high-performance liquid chromatography (DHPLC) as a rapid gene typing tool for β thalassemia. Methods 226 suspicious samples were screened with MCV, RDW, erythrocytcte agility and hemoglobin electrophoresis. The final diagnosis ofβ thalassemia genotype was made by DHPLC and PCR-reverse dot blot (PCR-RDB). Results Sixty-nine samples (30. 5% ) were eventually diagnosed as βthalassemia by PCR-RDB. The genotyping results for βthalassemia identified by DHPLC were complete agreement with genotyping results by PCR-RDB. We found 37 cases of CD41/CD42 ( - TCTT) frame shift mutation(54% ) ; 12 cases of IVS - Ⅱ - 654 (C→T) insertion mutation( 17% ) ;10 cases of TATA - 28 (A→G) transcription mutation ( 15% ) ;5 cases of CD17 (A→T)nonsense mutation ( 7% ) ; 5 cases of CD71/CD72 ( + A) frame shift mutation (7%). Conclusion The DHPLC is a rapid, sensitive , efficient and highly accurate assay in the diagnosis of β-thalassemia.
8.Effect of systemic lupus erythematosus on right heart function evaluated by parameters recommended by the American Society of Echocardiography
Hang ZHAO ; Xuedong SHEN ; Xiulan SONG ; Zhiqing QIAO ; Tingyan XU ; Jieyan SHEN ; Ben HE
Chinese Journal of Ultrasonography 2013;(3):199-203
Objective To evaluate the right heart dysfunction in SLE patients with/ without pulmonary arterial hypertension (PAH) using the parameters recommended by the American Society of Echocardiography (ASE),and to examine whether the right heart dysfunction is directly related to elevated pulmonary arterial systolic pressure(PASP) and pulmonary vascular resistance(PVR).Methods Study population composited of 43 patients with SLE.The patients were divided into two groups according to the PASP measured by echocardiography:Group A was 24 patients with PASP ≤35 mm Hg,Group B was 19patients with PASP>35 mm Hg.Twenty-two healthy subjects with age and gender matched were set as control group.Routine transthoracic echocardiography study was performed on all patients and 26 parameters were measured in order to compare the differences of the parameters among the three groups.Results There were significant differences in 17 parameters among the three groups (P <0.05).Tricuspid annular plane systolic excurtion(TAPSE) and E/A ratio of tricuspid flow velocities in SLE patients without PAH significantly decreased compared to control group (P =0.04 and 0.03).There were significant differences in 11 parameters between SLE with and without PAH group (P <0.05).Multivariate logistic regression analysis indicated that after adjustment for age and gender,the patients with elevated PVR associated with a 6.18-fold increase in right ventricular dysfunction compared to the patients with normal PVR (P =0.02).Conclusions The impairment of right ventricular function in SLE patients was directly related to PVR and PASP.Elevation of PVR was an important predictor for right heart dysfunction.
9.Research and implementation of gray-scale blood flow imaging system of high frequency ultrasound
Shaojuan HU ; Chao PANG ; Xuan GAO ; Jialu ZHOU ; Xuedong SONG ; Jianjun JI ; Jun YANG
International Journal of Biomedical Engineering 2016;39(2):92-96,后插2
Objective To study the method of gray-scale blood flow imaging and image processing in condition of high frequency ultrasound,and the implementation of the system.Methods On the base of research of scattered signals of red blood cells in high frequency ultrasound,20 MHz ultrasound mechanical and linear scanning probe was used to transmit a number of pulses on a scan line.Pulse-echo subtraction method was used to obtain the blood flow information.At the end,simulated blood vascular was used to conduct flow imaging,and the obtained images were analyzed.Results Experiment results showed that clear blood flow images were obtained using this system.The noise from perivascular tissue could be filtered and the signals from blood flow could be enhanced after image processing.Conclusions In the detection of superficial blood vessel,blood flow signals can be obtained even using single pulse emitting via high frequency ultrasound.The blood flow imaging system can be implemented after image processing.
10.Circulating miR-155 in whole blood of patients with breast cancer
Xueying ZHANG ; Linlin ZHEN ; Xuedong HAN ; Jianhua SHI ; Wei SONG ; Xiaolan QIU
Journal of Endocrine Surgery 2012;06(2):77-80
ObjectiveTo investigate the expression of miR-155 in whole blood of patients with breast cancer and explore the possibility of miR-155 in whole blood as a marker of beast cancer. Methods65 cases (breast cancer:47 cases, non-breast cancer:18 cases) in Thyroid and Breast Surgery Department of No.1 People's Hospital of Huai'an from Dec 2010 to Apr 2011 were enrolled according to the selected criteria.Two milliliters anticoagulant blood were sampled to isolate total RNA.The expression level of miR-155 in whole blood was measured by real-time quantitative polymerase chain reaction (real-time qPCR)analysis.The relationship between the expression level of miR-155 in whole blood and the clinical pathological fearutres was analyzed.ResultsThe expression level of miR-155 in breast cancer patients was up-regulated compared with that in non-breast cancer patients(P < 0.05).The expression level of miR-155 in patients with positive lymph nodes was up-regulated compared with that in patients with negative lymph nodes( P < 0.05).The expression level of miR-155 in stage Ⅲ breast cancer was up-regulated compared with that in stage Ⅰ & Ⅱ breast cancer( P < 0.05 ).The expression level of miR-155 in patients with positive ER and PR was down-regulated compared with that in patients with negative ER and PR breast cancer.Conclusion The study demonstrates that the expression of miR-155 in whole blood is related to clinical pathological features of patients with breast cancer and can be used as a potential marker of breast cancer.