1.The value of DWI and ADC of 1.5T magnetic resonance in differential diagnosis for localized prostate cancer, chronic inflammatory response and benign hyperplasia
Peng WANG ; Yu BAI ; Hongqiang XUE
China Medical Equipment 2017;14(8):80-83
Objective:To compare and analyze the value of diffusion weighted imaging (DWI) and apparent diffusion coefficient (ADC) of 1.5T magnetic resonance (MR) in differential diagnosis for localized prostate cancer, chronic inflammatory response and benign hyperplasia.Methods: 80 patients with localized prostate cancer were enrolled in the research. The signal to noise ratio (SNR) of DWI, ADC value and semi-quantitative classification of DWI on lesions were measured, and the diagnostic efficiencies of them were compared by using ROC curve.Results: In the 80 patients with localized prostate cancer patients, there were 52 malignant lesions and 43 benign lesions in peripheral band, and there were 31 malignant lesions and 46 benign lesions in central gland. The ADC values of prostate cancer in peripheral band and central gland were 0.91±0.12 and 0.86±0.15, respectively, and they were significantly lower than that of normal tissue (1.68±0.23 and 1.28±0.31) and benign lesions (1.24±0.21 and 1.12±0.16). The semi-quantitative classifications of DWI for benign lesions were significantly higher than that for malignant lesions in peripheral band and central gland, respectively (x2=20.88,x2=12.14;P<0.05). For the diagnostic efficiency of ADC, the sensitivities of benign and malignant lesions in peripheral band and malignant gland were 91.3% and 79.1%, respectively, and the specificities of them were 89.6% and 70.2%. And they was significant higher than the corresponding sensitivities (71.2% and 51.3%)and specificities (78.4% and 65.8%) of DWI imaging.Conclusion: Both of DWI and ADC of 1.5T magnetic resonance are the important indexes in differential diagnosis for prostate cancer, chronic inflammatory response and benign hyperplasia, while ADC value is better than DWI image in the clinical efficiency.
2.Dynamic observation of ossification process in a rat femur distraction model by living small animal Micro-CT
Jing XUE ; Jiang PENG ; Aiyuan WANG
Orthopedic Journal of China 2006;0(09):-
[Objective]In order to dynamically observe the ossification process by living small animal Micro-CT in a rat femur distraction osteogenesis (DO) model,the author applied a special designed external fixiator system. [Methods]A femur DO model was made on 12 SD rats.After 7 days of latency,the femurs were distracted at a speed of 0.25 mm every 12 hours for 14 days.At the first day of consolidation period,the steel external fixiators were substituted by radio-transparent polymer splint material made fixiators.At 7 and 21 days of consolidation period,two randomly selected rats were sacrificed for histological examination.The other 8 rats were selected for X-ray and living Micro-CT examination at 0,7,21,35 days of consolidation period.All animals were sacrificed at 35 days of consolidation period,5 for biomechanical test,3 for histological examination.[Results]There was no significant new bone formed in distracted zone at latency and distraction periods.The volume of distracted zone increased little in the following 5 weeks of consolidation period.Bone volume,bone mineral content,bone volume fraction,and the number of trabeculae all increased over the consolidation period,while mineral content of mineralized tissue and thickness of traleculae did not increased until 3 weeks after consolidation began.At final observation (56 days post operation),there still exist un-mineralized cartilage tissues in the central of distracted zone,and the distracted femurs had lower biomechanical property when compared with corresponding normal femurs.[Conclusion]1) Radio-transparent polymer splint is a satisfactory substitute of steel external fixator.2) Micro-CT is a useful tool for dynamical observing and evaluating bone formation status in DO model.3) The increasing of bone volume began at the end of distraction,lasting at least 5 weeks,while the remodeling of new formed bone began 3 weeks after distraction ended.The increasing and remodeling of new formed bone was not concord.This result indicates that,in order to obtain proper results,the corresponding interference should be taken at different time points.
6.Preparation and Characterization of Celecoxib-loaded PLGA Nanoparticles
Min WANG ; Peng XIE ; Yimin YANG ; Qiuyan LI ; Qiang XUE
China Pharmacy 2015;(25):3561-3564
OBJECTIVE:To prepare and characterize celecoxib-loaded PLGA nanoparticles. METHODS:Emulsification-solvent evaporation method was adopted to prepare celecoxib-loaded PLGA nanoparticles. With encapsulation efficiency and particle size as the indexes,Plackett-Burman design was preferred to screen the formulation and variables which had a significant effect on the property of nanoparticles. And then Box-Behnken response surface method was used to further optimize selected variables including mass concentration of PLGA,ultrasonic power and ultrasonic time,followed by verification. Malvern particle size analyzer was used to determine the particle size distribution of nanoparticles and Zeta potential of nanoparticle by the optimal formulation technol-ogy,and transmission electron microscope was used to observe the morphology of the nanoparticles,and their drug release in vitro behavior and stability(25,5 ℃)were also observed. RESULTS:The optimal formulation and technology was as follows as PLGA mass concentration of 30.0%,ultrasonic power of 180 W and ultrasonic time of 8 min. For the prepared nanoparticles,encapsula-tion efficiency and particle size were (85.7 ± 4.1)% and (226.1 ± 36.1) nm (n=3) respectively;particle size distribution was (176.2±41.2)nm,polydispersity index was 0.211±0.021,and Zeta potential was(-37.3±1.6)mV. Under the electron micro-scope,the nanoparticles were homogeneous in particle size and distributed spheroidally,with 24 h accumulative release of 52.4%. They were stable within 3 months at 5℃. CONCLUSIONS:Celecoxib-loaded PLGA nanoparticles have been prepared successfully.
7.Preparation and Pharmacokinetics in Rats of Celecoxib Nanosuspension
Qiuyan LI ; Min WANG ; Peng XIE ; Juntao LI ; Qiang XUE
China Pharmacist 2016;19(2):258-261
Objective:To prepare celecoxib nanosuspension ( CXB-NSs) and study the pharmacokinetics of CXB-NSs in rats. Methods:CXB-NSs were prepared by an anti-solvent precipitation and high pressure homogenization method. The particle size, polydispersion index ( PdI) and zeta potential of the nanosuspension were studied. Totally 12 Wistar rats were randomly divided into CXB-NSs group and CXB suspension group, and gastric drug dose was 100 mg·kg-1 . CXB concentration in plasma was determined by HPLC and the pharmacokinetic parameters were calculated by 3P97 software. Results: The particle size, polydispersion index, zeta potential of CXB-NSs was (442. 5 ± 61. 9) nm, 0. 312 ± 0. 057 and ( -31. 6 ± 3. 9) mV, respectively. AUC (0-t) of CXB suspension and CXB-NSs was (5.13 ±0.77) and (13.51 ±3.18) mg·L-1·h, half time (t1/2) was (12.31 ±1.91) and (12.73 ±1.83) h, Tmax was (2. 48 ± 0. 37) and (1. 41 ± 0. 27) h and Cmax was (0. 94 ± 0. 31) and (2. 38 ± 0. 25) mg·L-1 , respectively. Conclusion:CXB-NSs can remarkably increase bioavailability in rats.
9.A Rapid Filtration Sampling Probe for Fermentation Broth On-line Measurement
Xuejin GAO ; Jixing XUE ; Peng ZHANG ; Pu WANG
Chinese Journal of Analytical Chemistry 2014;(6):924-928
An inner-bioreactor rapid filtration sampling probe was designed to resolve the problems of continuous sampling the fermentation broth in on-line measurement the fermentation process. The probe consists of a support, a plug valve, an O-ring, a filter membrane and a pipe cover. It can be inserted directly into the bio-reactor withstanding high-temperature sterilization before fermentation, or preventing the bacteria's invasion during sampling. Fermentation broth in tank is cross-flow filtrated by a cylindrical ceramic membrane which is used as filtration membrane, and then the sterile permeated liquid is transported to the analyzer by a peristaltic pump. The sampling experiments using this device was described for sampling glucose solution indicating it is suitable for fermentation online sampling. The sampling rate is up to 3. 0 mL/ min, glucose permeability maintains 100% , and the delay time caused by the probe is about 2 min.
10.Total knee arthroplasty with Gemini MKII rotating-platform prosthesis
Qiang WANG ; Junying SUN ; Feng XUE ; Xiaowen SHENG ; Yuqin PENG
Chinese Journal of Tissue Engineering Research 2014;(13):2018-2023
BACKGROUND:Total knee arthroplasty mainly used fixed platform, but more and more movable platform was selected year by year in the clinic. Rotary platform theoretical y can apparently improve the curative effects, but it has not been verified in the clinic.
OBJECTIVE:To summarize the design characteristics and clinical results of Gemini MKII (Link, Germany) rotary platform.
METHODS:From January 2004 to January 2009, 108 patients (119 knees) including 31 males and 77 females were treated with total knee arthroplasty by using Gemini MKII system. There were 97 unilateral cases and 11 bilateral cases at the first stage of replacement. Preoperative diagnosis:1 case of hemophilic arthritis, 1 case of venereal Charcot’s disease, 8 cases of post-traumatic arthritis, 11 cases of rheumatoid arthritis, and 87 cases of degenerative osteoarthritis. The prosthesis was fixed with bone cement. None received patel ar replacement. RESULTS AND CONCLUSION:None experienced infection, femoral condyle fracture or nerve and vascular damage. Except bilateral replacement, the average operation time of unilateral replacement was (56±13) minutes. Average postoperative hemoglobin decreased (25±5) g/L. After replacement, hemoglobin maintained over 100 g/L in 83 patients (86%), without blood transfusion. Knee joint score and function score recovered to (92.0±4.7) points and (90.3±6.8) points at half years after replacement, and became (94.4±3.2) points and (91.6±5.9) points during final fol ow-up, which was significantly improved as compared with that pre-replacement (P<0.01). No revision surgery should be done for lining prolapse or spin out, osteolysis and prosthesis loosening. These results indicated that the early and midterm results of Gemini MKII rotating-platform prosthesis were satisfactory, but the long-term results remain to be confirmed.