1.Building harmonious campus by developing excellent courses
Yanqin WANG ; Chaopin LI ; Xiyin GAO
Chinese Journal of Medical Education Research 2006;0(07):-
Establishment of excellent courses in colleges and universities plays a positive role in building harmonious campus.Building excellent courses helps to foster students' good learning attitude,to improve the young teachers' teaching methods and teaching ability so as to improve teaching quality.It also helps to deepen teaching reform,to promote an increase in the level of scientific research.It pushes towards mutual promotion and coordinated development between teaching and scientific research,with a view to achieving the aim of building all-round harmonious campus.
2.Studies on immunization effects of single vaccine delivery system of biodegradable microspheres of recombinant glutathione-S-transferase from Schistosoma japonicum
Xiaoniu TANG ; Pingping ZHOU ; Xiyin GAO ; Xuelong WANG
Chinese Journal of Schistosomiasis Control 1989;0(02):-
Objective To detect the dynamic changes of antibody and cytokines in the serum induced by single vaccine delivery system (SVDS) of biodegradable microspheres of recombinant glutathione-S-transferase from Schistosoma japonicum (rSjGST) in mice. Methods By using the constructed expression plasmid pET28a(+)-SjGST, rSjGST was expressed by E.coli BL21. After purified through the column of resin,the biodegradable microspheres of rSjGST were prepared with PLGA (Poly lactic-co-glycolic acid, PLGA 75/25).Six-week BALB/c female mice were immunized subcutaneously with a single vaccine, and the blood was collected from eyes on the 6th, 9th, 12th, 15 th, 18th, 21th week respectively. The dynamic levels of serum specific antibody IgG, IL-2 and IFN-? were detected. Results Compared with the control group, there was a significant difference of serum specific antibody IgG of every immune group (P
3.Early response and acute adverse effect after particle radiation therapy for adenoid cystic carcinoma of the head and neck
Jing GAO ; Lin KONG ; Xiyin GUAN ; Jiyi HU ; Xiaofei ZHANG ; Yingchao ZHU ; Jiade LU
Chinese Journal of Radiological Medicine and Protection 2016;36(8):607-610
Objective To study the early response and acute/subacute adverse effects after particle radiation therapy for adenoid cystic carcinoma (ACC) of the head and neck.Methods Between May 2015 and March 2016,a total of 8 patients with ACC of the head and neck were treated using proton and/or carbon-ion radiation therapy.Three patients had early stage and 5 had locally advanced disease.Five patients had an R2 and three achieved an R1 resection.Results Seven patients received intensitymodulated proton therapy (IMPT) followed by intensity-modulated carbon-ion therapy (IMCT) boost.One patient received IMPT only.Among the five patients who had an R2 resection,2/3 patients had partial response (PR)/stable disease (SD) at the end of radiation,0/3 achieved PR/complete response (CR) at 1-month follow-up,and 1/2 achieved PR/CR at 3-months' follow-up after the completion of radiation,respectively.Two patients experienced Grade Ⅲ mucositis during radiation therapy.No patient experienced moderate or severe skin reactions.At the time of this analysis,all patients are alive and no patient had disease progression or recurrence.Conclusions The short-term outcomes indicated that particle therapy is safe and potentially efficacious in the management of head and neck ACC.However,longer follow up is needed to assess late toxicities and long-term efficacy.
4.Phase I/II trial evaluating concurrent carbon-ion radiotherapy plus chemotherapy for salvage treatment of locally recurrent nasopharyngeal carcinoma
Kong LIN ; Gao JING ; Hu JIYI ; Hu WEIXU ; Guan XIYIN ; Lu RONG ; JLu JIADE
Chinese Journal of Cancer 2016;35(12):743-753
Background:After deifnitive chemoradiotherapy for non-metastatic nasopharyngeal carcinoma (NPC), more than 10% of patients will experience a local recurrence. Salvage treatments present signiifcant challenges for locally recur-rent NPC. Surgery, stereotactic ablative body radiotherapy, and brachytherapy have been used to treat locally recur-rent NPC. However, only patients with small-volume tumors can beneift from these treatments. Re-irradiation with X-ray—based intensity-modulated radiotherapy (IMXT) has been more widely used for salvage treatment of locally recurrent NPC with a large tumor burden, but over-irradiation to the surrounding normal tissues has been shown to cause frequent and severe toxicities. Furthermore, locally recurrent NPC represents a clinical entity that is more radio-resistant than its primary counterpart. Due to the inherent physical advantages of heavy-particle therapy, precise dose delivery to the target volume(s), without exposing the surrounding organs at risk to extra doses, is highly feasible with carbon-ion radiotherapy (CIRT). In addition, CIRT is a high linear energy transfer (LET) radiation and provides an increased relative biological effectiveness compared with photon and proton radiotherapy. Our prior work showed that CIRT alone to 57.5 GyE (gray equivalent), at 2.5 GyE per daily fraction, was well tolerated in patients who were pre-viously treated for NPC with a deifnitive dose of IMXT. The short-term response rates at 3–6months were also accept-able. However, no patients were treated with concurrent chemotherapy. Whether the addition of concurrent chemo-therapy to CIRT can beneift locally recurrent NPC patients over CIRT alone has never been addressed. It is possible that the beneifts of high-LET CIRT may make radiosensitizing chemotherapy unnecessary. We therefore implemented a phase I/II clinical trial to address these questions and present our methodology and results. Methods and design:The maximal tolerated dose (MTD) of re-treatment using raster-scanning CIRT plus concur-rent cisplatin will be determined in the phase I, dose-escalating stage of this study. CIRT dose escalation from 52.5 to 65 GyE (2.5 GyE×21–26 fractions) will be delivered, with the primary endpoints being acute and subacute toxicities. Effcacy in terms of overall survival (OS) and local progression-free survival of patients after concurrent chemotherapy plus CIRT at the determined MTD will then be studied in the phase II stage of the trial. We hypothesize that CIRT plus chemotherapy can improve the 2-year OS rate from the historical 50% to at least 70%. Conclusions:Re-treatment of locally recurrent NPC using photon radiation techniques, including IMXT, provides moderate effcacy but causes potentially severe toxicities. Improved outcomes in terms of effcacy and toxicity proifle are expected with CIRT plus chemotherapy. However, the MTD of CIRT used concurrently with cisplatin-based chemo-therapy for locally recurrent NPC remains to be determined. In addition, whether the addition of chemotherapy to CIRT is needed remains unknown. These questions will be evaluated in the dose-escalating phase I and randomized phase II trials.
5.Preliminary study of pencil beam scanning proton and carbon ion therapy for chordoma and chondrosarcoma of head and neck
Xiyin GUAN ; Jing GAO ; Jiyi HU ; Weixu HU ; Jing YANG ; Youqi YANG ; Tingting XU ; Chaosu HU ; Jiade LU ; Lin KONG
Chinese Journal of Radiation Oncology 2018;27(10):886-889
Objective To evaluate the short-term efficacy and adverse events of pencil beam scanning proton and carbon ion therapy in the treatment of chordoma and chondrosarcoma of the head and neck.Methods Between July 2014 and July 31,2017,61 patients with chordoma and chondrosarcoma of the head and neck receiving proton and heavy ion therapy as the first course of radiotherapy were enrolled.Among them,45 patients were diagnosed with chordoma and 16 cases of chondrosarcoma,39 male and 22 female.The median age was 38 years old (range:14-70 years).The median maximum tumor diameter was 4.1 cm (range:0-8.6 cm).The clivus and the cervical spine were the primary tumor sites.Results Eight patients received proton therapy,21 patients were treated with proton combined with carbon ion therapy and 32 patients received carbon ion therapy.All patients successfully completed the planned radiotherapy.The medial follow-up time was 21 months (range:7-47 months).No grade 3-4 acute toxicity was observed.Only one patient suffered from radiation-induced temporal lobe injury.The 2-year progression-free survival (PFS)and overall survival (OS) were 91% and 100%.Conclusions Pencil beam scanning proton and heavy ion therapy yields relatively favorable short-term outcomes in the treatment of chordoma and chondrosarcoma of the head and neck.Nevertheless,the long-term clinical efficacy and safety remain to be investigated during follow-up.
6.The preliminary result of proton and carbon ion therapy for recurrent chordoma and chondrosarcoma of skull base and cervical spine
Xiyin GUAN ; Jing GAO ; Jiyi HU ; Weixu HU ; Jing YANG ; Chaosu HU ; Lin KONG ; Jiade LU
Chinese Journal of Radiological Medicine and Protection 2020;40(6):434-438
Objective:To evaluate the short-term tumor control and toxicity of recurrent skull base and cervical spine chordoma and chondrosarcoma in patients treated with pencil beam scanning proton and heavy ion therapy.Methods:Between June 30 th, 2014 and July 30 th, 2018, a total of 45 skull base and cervical spine chordoma ( n=39) and chondrosarcoma ( n=6) patients (28 males and 17 females; mean age at initial presentation of 44 years, range, 14-76 years) were treated in our center for the course of radiotherapy. The median maximum tumor volume was 57 cm 3 (range, 6.6-231.7 cm 3). There were 31 post-operative recurrent patients and 14 post-operative and post-radiated recurrent patients. One patient received proton therapy, 21 patients received combined proton and carbon ion therapy, 23 patients received carbon ion therapy. Results:All patients completed the whole course of the treatment. The median follow-up time was 29 months (range: 8-57 months), the 2-year overall survival (OS), local control (LC), and progression-free survival (PFS) were 82.7%, 85.3%, and 73.8%, respectively. There were no other grade 3-4 acute or late radiation-induced toxicity except one grade 3 acute mucositis. The 2-year OS rates for patients after first-time radiation vs. re-irradiation were 96.2% and 50.3% ( χ2=16.969, P<0.05). Conclusions:The short-term outcomes of pencil beam scanning proton and heavy ion therapy for recurrent skull base and cervical spine chordoma and chondrosarcoma is favorable. Further study is needed for long-term efficacy and safety.
7.Preliminary study of intensity-modulated carbon ion reirradiation for locoregionally recurrent nasopharyngeal carcinoma after definitive IMRT——Clinical experience from Shanghai Proton Heavy Ion Hospital
Jiyi HU ; Jing GAO ; Weixu HU ; Jing YANG ; Xiyin GUAN ; Xianxin QIU ; Lin KONG ; Jiade LU
Chinese Journal of Radiation Oncology 2020;29(3):161-165
Objective To evaluate the short-term efficacy and toxicities of intensity-modulated carbon ion radiotherapy (IMCT) for patients with locoregionally recurrent nasopharyngeal carcinoma after intensity-modulated radiotherapy (IMRT).Methods A total of 112 patients with locoregionally recurrent nasopharyngeal carcinoma undergoing salvaging IMCT between May 2015 and February 2018were enrolled in the study.All patients previously received one course of definitive X-ray IMRT.Among them,10 patients (9%) were diagnosed with stage Ⅰ,26 patients (23%) with stage Ⅱ,41 patients (37%) with stage Ⅲ and 35 patients (31%) with stage Ⅳnasopharyngeal carcinoma,respectively.The median age of the cohort was 48 years (range,17-70 years) old.The median dose to the gross tumor volume (GTV) was 60 GyE (range,50-69 GyE).Results With a median follow-up time of 20 months (range,5-45 months),20 patients died and 42 patients developed local recurrence.The 2-year overall survival (OS) and local progression-free survival (LPFS) rates were 85% and 52%.Both univariate and multivariate analyses demonstrated that stage Ⅳ disease was associated with significantly worse OS.No predictors were found for LPFS.No acute toxicity of grade 3 or higher was observed during reirradiation.Severe (grade 3 or above) late toxicities included xerostomia (n =1),hearing impairment (n =2),temporal lobe injury (n =1) and mucosal necrosis (n =19).Conclusions IMCT is an efficacious and safe treatment for patients with locoregionally recurrent nasopharyngeal carcinoma with acceptable toxicity profile.Long-term follow-up is necessary to further evaluate the long-term efficacy and late toxicities.
8.The preliminary report of a registration clinical trial of proton and heavy ion irradiation
Jiade LU ; Ming YE ; Xiaomao GUO ; Shen FU ; F.Michae MOYERS ; Qing ZHANG ; Jingfang MAO ; Lin KONG ; Chien Wen HSI ; Kambiz SHAHNAZI ; Jingfang ZHAO ; Zhen ZHANG ; Xiumei MA ; Songtao LAI ; Xiaomeng ZHANG ; Ningyi MA ; Yunsheng GAO ; Xin CAI ; Xiyin GUAN ; Junhua ZHANG ; Bin WU ; Jingyi CHENG ; Yin?xiang?zi SHENG ; Wei REN ; Jun ZHAO ; Lining SUN ; Guoliang JIANG
Chinese Journal of Oncology 2018;40(1):52-56
Objective To verify the safety and efficacy of IONTRIS particle therapy system ( IONTRIS) in clinical implementation. Methods Between 6.2014 and 8.2014, a total of 35 patients were enrolled into this trial:31 males and 4 females with a median age of 69 yrs ( range 39?80) . Ten patients had locally recurrent head and neck tumors after surgery, 4 cases with thoracic malignancies, 1 case with hepatocellular carcinoma, 1 case with retroperitoneal sarcoma, and 19 cases with non?metastatic prostate carcinomas. Phantom dose verification was mandatory for each field before the start of radiation. Results Twenty?two patients received carbon ion and 13 had proton irradiation. With a median follow?up time of 1 year, all patients were alive. Among the 16 patients with head and neck, thoracic, and abdominal/pelvic tumors, 2, 1, 12, and 1 cases developed complete response, partial response, stable disease, or disease progression, respectively. Progression?free survival rate was 93.8% (15/16). Among the 19 patients with prostate cancer, biological?recurrence free survival was 100%. Particle therapy was well tolerated in all 35 patients. Twenty?five patients (71.4%) experienced 33 grade 1 acute adverse effects, which subsided at 1 year follow?up. Six ( 17.1%) patients developed grade 1 late adverse effects. No significant change in ECOG or body weight was observed. Conclusions IONTRIS is safe and effective for clinical use. However, long term follow?up is needed to observe the late toxicity and long term result.
9.The preliminary report of a registration clinical trial of proton and heavy ion irradiation
Jiade LU ; Ming YE ; Xiaomao GUO ; Shen FU ; F.Michae MOYERS ; Qing ZHANG ; Jingfang MAO ; Lin KONG ; Chien Wen HSI ; Kambiz SHAHNAZI ; Jingfang ZHAO ; Zhen ZHANG ; Xiumei MA ; Songtao LAI ; Xiaomeng ZHANG ; Ningyi MA ; Yunsheng GAO ; Xin CAI ; Xiyin GUAN ; Junhua ZHANG ; Bin WU ; Jingyi CHENG ; Yin?xiang?zi SHENG ; Wei REN ; Jun ZHAO ; Lining SUN ; Guoliang JIANG
Chinese Journal of Oncology 2018;40(1):52-56
Objective To verify the safety and efficacy of IONTRIS particle therapy system ( IONTRIS) in clinical implementation. Methods Between 6.2014 and 8.2014, a total of 35 patients were enrolled into this trial:31 males and 4 females with a median age of 69 yrs ( range 39?80) . Ten patients had locally recurrent head and neck tumors after surgery, 4 cases with thoracic malignancies, 1 case with hepatocellular carcinoma, 1 case with retroperitoneal sarcoma, and 19 cases with non?metastatic prostate carcinomas. Phantom dose verification was mandatory for each field before the start of radiation. Results Twenty?two patients received carbon ion and 13 had proton irradiation. With a median follow?up time of 1 year, all patients were alive. Among the 16 patients with head and neck, thoracic, and abdominal/pelvic tumors, 2, 1, 12, and 1 cases developed complete response, partial response, stable disease, or disease progression, respectively. Progression?free survival rate was 93.8% (15/16). Among the 19 patients with prostate cancer, biological?recurrence free survival was 100%. Particle therapy was well tolerated in all 35 patients. Twenty?five patients (71.4%) experienced 33 grade 1 acute adverse effects, which subsided at 1 year follow?up. Six ( 17.1%) patients developed grade 1 late adverse effects. No significant change in ECOG or body weight was observed. Conclusions IONTRIS is safe and effective for clinical use. However, long term follow?up is needed to observe the late toxicity and long term result.
10. The preliminary report of a registration clinical trial of proton and heavy ion irradiation
Jiade LU ; Ming YE ; Xiaomao GUO ; Shen FU ; F. Michael MOYERS ; Qing ZHANG ; Jingfang MAO ; Lin KONG ; Wen Chien HSI ; Kambiz SHAHNAZI ; Jingfang ZHAO ; Zhen ZHANG ; Xiumei MA ; Songtao LAI ; Xiaomeng ZHANG ; Ningyi MA ; Yunsheng GAO ; Xin CAI ; Xiyin GUAN ; Junhua ZHANG ; Bin WU ; Jingyi CHENG ; Yin-xiang-zi SHENG ; Wei REN ; Jun ZHAO ; Lining SUN ; Guoliang JIANG
Chinese Journal of Oncology 2018;40(1):52-56
Objective:
To verify the safety and efficacy of IONTRIS particle therapy system (IONTRIS) in clinical implementation.
Methods:
Between 6.2014 and 8.2014, a total of 35 patients were enrolled into this trial: 31 males and 4 females with a median age of 69 yrs (range 39-80). Ten patients had locally recurrent head and neck tumors after surgery, 4 cases with thoracic malignancies, 1 case with hepatocellular carcinoma, 1 case with retroperitoneal sarcoma, and 19 cases with non-metastatic prostate carcinomas. Phantom dose verification was mandatory for each field before the start of radiation.
Results:
Twenty-two patients received carbon ion and 13 had proton irradiation. With a median follow-up time of 1 year, all patients were alive. Among the 16 patients with head and neck, thoracic, and abdominal/pelvic tumors, 2, 1, 12, and 1 cases developed complete response, partial response, stable disease, or disease progression, respectively. Progression-free survival rate was 93.8% (15/16). Among the 19 patients with prostate cancer, biological-recurrence free survival was 100%. Particle therapy was well tolerated in all 35 patients. Twenty-five patients (71.4%) experienced 33 grade 1 acute adverse effects, which subsided at 1 year follow-up. Six (17.1%) patients developed grade 1 late adverse effects. No significant change in ECOG or body weight was observed.
Conclusions
IONTRIS is safe and effective for clinical use. However, long term follow-up is needed to observe the late toxicity and long term result.