1.Preliminary study of radiation dosage in the lower limb factures surgery with single source dual energy CT
Sensen YAN ; Yang LI ; Min LUO ; Xiuya CEN
Chinese Journal of Primary Medicine and Pharmacy 2015;22(4):500-503,641
Objective To assess the clinical application value of single-source dual energy CT(SSDE),by measuring the multi-slice CT(MSCT) and single-source dual energy CT(SSDE) lower limb fractures image noise and contrast noise ratio(CNR),comparing the difference in the radiation dosage.Methods 39 cases of lower extremity fractures by clinical diagnosis were included in the study.Preoperation or postoperation the patients underwent MSCT scans,postoperation or postoperative follow-up SSDE CT scans were conducted,two sets of images were achieved.We measured and compared conventional CT group with 130 key energy spectrum group (prior studies showed the elimination of metal artifacts,images,subjective scoring the highest photon energy level) no significant artifacts cancellous bone area,compared the image background noise and contrast noise ratio (CNR),and radiation dosage,using paired sample t-test.Results Two sets of data for the same patient before and after surgery or after review of images,which body mass index (BMI) was negligible.The CTDIvol value of the conventional MSCT was (7.94 ± 1.69) mGy,the dual-energy CT was (7.04 ± 0.97) mGy,with significant difference (t =2.71,P < 0.05) ; The image noise of the conventional MSCT was (44.36 ± 15.66) Hu,the dual-energy CT was (15.04 ± 8.23) Hu,with significant difference (t =15.26,P < 0.05) ; The CNR of the conventional MSCT was (3.96 ± 1.78),the dual-energy CT was (4.62 ± 2.80),with significant difference (t =-2.14,P < 0.05).Conclusion Compared with conventional MSCT,single source dual-energy CT imaging provides improved image CNR,obviously eliminate metal artifacts,to better show the complex structure for lower limb fracture surgery,and reduction in radiation dosage.
2.The value of single-source spectrum CT in differentiating of calcification and tophus
Min LUO ; Sensen YAN ; Xiuya CEN ; Yuantong GAO ; Qing JIA
Chinese Journal of Primary Medicine and Pharmacy 2016;23(5):679-682
Objective To evaluate the advantage of single -source spectrum CT in differentiating of calcifi-cation and tophus.Methods 146 cases of clinical suspected patients with gout pain were scaned by single -source spectrum CT,observed the adjacent to the bone and joint hyperplasia and showing characteristics of gout stone,coun-ted quantity,size and position of the sedimentary tophus.Diagnosed by American rheumatism association standard as the gold standard,computed the sensitivity,specific degrees and accuracy of showing tophus of single -source spec-trum CT and conventional CT,and evaluated the advantage of differentiating adjacent to the bone and joint hyperplasia and gout stone of single -source spectrum CT.Results Diagnosis of gout in 105 cases.Scaned 349 joints,positive in 341 of them,The first plantar toe joint involvement was obvious[118,34.60%(118/341)];The result showed that the sensitivities of the tophus,specific and accurate rate of the conventional CT were 63.80%(67 /105),65.85%(27 /41),64.38%(94 /146),which of single -source spectrum CT were 96.19%(101 /105),87.80%(36 /41), 93.84%(137/146),the differences of sensitivity,specificity and accuracy between the two methods were statistical significance(χ2 =34.42,555,38.34,all P <0.05).Conclusion Single -source spectrum CT in gout stone adjacent to the bone and joint has higher sensitivity and accuracy,specific degree,it is higher than conventional CT and provide a new noninvasive imaging technique for the identification of the peripheral bone and joint of the bone.