1.HPLC Determination of Berberine Hydrochloride in Xiaoyou Capsules
Chunhui ZHANG ; Zhao YANG ; Xiuming SHAN
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(01):-
Objective To establish a method for the content determination of berberine hydrochloride in Xiaoyou Capsules.Method A PR-HPLC method was adopted with a SHIMADZU RP-ODS C18 column as stationary phase and 0.05 mol/L KH2PO4(adjust pH to 3 with H3PO4)-Acetonitrile(70:30)as mobile phase.The detector wavelength was at 265 nm,column temperature was at 40 ℃and the flow rate was 1.0 mL/min.Results Berberine hydrochloride in Xiaoyou capsules showed a good linearity in the range of 0.010 73~0.214 6 ?g.The average recovery was 99.87 %,RSD was 1.43 %.Conclusion The method is simple,reliable,with a good separation,so it can be used for the quality control of Xiaoyou Capsules.
2.Simultaneous Determination of Six Components in Refined Coronary Tablets by UHPLC-DAD
Xinrong LI ; Xiuming SHAN ; Chunhui ZHANG ; Chao FU ; Xuewei QIU
China Pharmacist 2016;19(9):1778-1780
Objective:To simultaneously determine six components ( paeoniflorin, rosmarinic acid, salvianolic acid B, ligustilide, clyptotanshinone and tanshinone ⅡA ) in refined coronary tablets by UHPLC-DAD. Methods: A Dikma Endevaorsil C18 column (2. 1 mm × 100 mm,1. 8 μm) was used to perform the determination, which was maintained at 30℃ during the analysis. The mobile phase was composed of acetonitrile and 0. 05% phosphoric acid at a flow rate of 0. 3 ml·min-1 with gradient elution. The detection wavelength was respectively set at 230,270,288 and 321 nm. Results:Paeoniflorin, rosmarinic acid, salvianolic acid B, ligustilide, clyptotanshinone and tanshinone ⅡA showed good linearity within the range of 0. 001 0-0. 010 2 μg ( r = 0. 999 8 ), 0. 005 7-0.056 9 μg(r =1.000 0), 0.005 3-0.052 7 μg(r = 1.000 0),0.002 1-0.020 6 μg(r = 1.000 0),0.001 1-0.011 2 μg(r =1. 000 0) and 0. 001 4-0. 014 4 μg(r=0. 999 8),respectively. The average recovery was 98. 78%(RSD=0. 50%), 97. 99%(RSD=0. 76%),98. 44%(RSD=0. 85%),99. 12%(RSD=0. 66%), 98. 82%(RSD=0. 81%) and 97. 80%(RSD=0. 80%), respec-tively. Conclusion:The method is simple, rapid and accurate, which can be used for the quality control of refined coronary tablets.
3.Content Determination of Heavy Metals in Xiaohuoluo Pills by Atomic Absorption Spectrometry
Xuewei QIU ; Xiuming SHAN ; Chunhui ZHANG ; Yu YU
China Pharmacist 2015;(2):338-340
Objective:To determine the content of lead, cadmium, arsenic, mercury and copper in Xiaohuoluo pills produced by 34 enterprises. Methods:Using microwave digestion, the contents of lead, cadmium and arsenic were determined by graphite furnace atomic absorption spectrometry;the content of mercury was determined by hydride generation atomic absorption spectrophotometry;the content of copper was determined by air-acetylene flame atomic absorption. Results: Lead, cadmium, arsenic and mercury in Xiao-huoluo pills from 34 different manufacturers were beyond the limits in various degrees. Conclusion: The method is simple and accu-rate, and can be used in the heavy metal determination of Xiaohuoluo pills.