1.Research on geometric feature of femoral medullary cavity and it's matching with intramedullary nail
Longfu LI ; Guanxing LI ; Xiuhai XIA ; Jianqiang MO ; Xingping WANG ; Dejun LIU ; Changqing HU
Chinese Journal of Orthopaedics 2012;32(6):565-569
Objective To investigate the geometric feature of femoral medullary cavity through CT scanning and it's matching with femoral intramedullary nail,and to analysis the reason for difficulties in implanting distal lock pin.Methods Thirty dried femur specimens were measured through CT scanning,and twenty images were taken evenly according to the total length of shaft of femur from each femur.In each image,the data of the central axis point and eight points around medullary cavity wall in X and Y axes were obtained,which were used to reconstruct the three-dimensional models of medullary cavity,central axis,intramedullary nail by computer software.And the models were overlapped for comparison.Then the coronal and sagittal fold line charts for central axis of medullary cavity were drawn.The inserting process of intramedullary nail was simulated to observe whether the nail would punch out of the medullary cavity wall.Results The central axis of femoral medullary cavity and intramedullary nail were overlapped and compared.They matched well in the coronal plane,but the curves of femoral medullary cavity were larger than those of intramedullary nails in sagittal plane.While simulating the inserting process of intramedullary nail,6 nails punched out of the medullary cavity wall in coronal plane (20%,6/30),so did 13 nails in sagittal plane (43%,13/30).Conclusion Intramedullary nails match well with most of the femoral medullary cavities.However,the anatomic structure of the femoral medullary cavity differs individually.Curves of some femoral medullary cavity are large,which can cause deformation of intramedullary nail,and this is the main reason for the failure of distal locking.
2.The application of multi-modal MRI in venous thrombolysis therapy for hyperacute cerebral arterial thrombosis
Zhenguo ZHAO ; Qingke BAI ; Haijing SUI ; Xiuhai XIE ; Xiaohui ZHAO ; Lianwen WANG ; Weiying XIA ; Lianjun LU ; Jian SHEN ; Yuan ZHOU ; Juan CHEN ; Cuirong CHEN ; Jinshi LI
Chinese Journal of Radiology 2009;43(3):239-243
Objective To investigate the value of MRI in thmmbolytic thempy of hyperacute cerebral arterial thrombosis.Methods One hundred and sixteen patients with acute cerebral arterial thrombosis were recruited.plain CT and multi.modal MRI were performed in all patients.Thirty-three patients with hyperacute cerebral infarction were treated bv recombinant tissue plasminogen activator(rt-PA) and followed-up periodically using MRI.Results The 33 patients with thrombolysis selected by MRI demonstrated clinical improvement.90 d moclified Rankin scale scores(mRs)were less than 2 and life quality Barthal indexes(BI)were from 80 to 100.The complication included one asymptomatic parenchymal hematoma(PH1)one weeks after thrombolytic therapy and 4(12.2%)hemorrhagic infarction(HI)6 to 24 hours after thrombolytic therapy.Condusions MRI has significant clinical value for the screening and follow-up of intravenous thrombolytic therapy of hyperacute ischemic stroke.MRI-based thrombolysis is a safe and effective method for hyperacute ischemic stroke.