1.Percutaneous argon-helium cryoablation for primary hepatocellular carcinoma:report of 300 cases
Chunping WANG ; Yinying LU ; Xinzhen WANG
Medical Journal of Chinese People's Liberation Army 2001;0(12):-
Objective To evaluate the therapeutic effect,safety and complication of percutaneous argon-helium cryoablation in the treatment of primary hepatocellular cancer(HCC).Methods Three hundred HCC patients were treated with percutaneous argon-helium cryoablation under ultrasound guidance with argon-helium cryosurgical system.Results Two hundred and thirty-three tumors(diameter ranged from 5.0cm to 15cm,with a mean of 7.2cm?2.8cm),in 165 patients were considered to be incompletely ablated,while 185 tumors(diameter ranged from 1.9cm to 7.0cm with mean value of 5.6cm?0.8cm) in 135 patients were completely ablated.There was a significant difference in tumor diameter between these two groups(P
2.Development of recruits training burnout self-reported questionnaires
Kui DING ; Wenchao WANG ; Xinzhen MENG ; Xiaoming LIU ; Yongbin SONG
Chinese Journal of Behavioral Medicine and Brain Science 2015;24(10):949-952
Objective To develop recruits training burnout self-reported questionnaires, and test the reliability and validity.Methods 780 recruits(360 for first test ,420 for second test) in Xinjiang were randomly assesscd with training burnout self-reported questionnaires.Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were applied to the data, and tested the reliability and validity of recruits training burnout self-reported questionnaires.Results The questionnaires consisted of 13 items and 3 dimensions.One of the dimensions (physically and psychologically exhausted situation, training-alienation, low accomplishment) , explained 61.599% of the total variance.Cronbach's α coefficient of the whole questionnaire was 0.837, Cronbach's α coefficient of each partial scale were between 0.775 and 0.807.Split-half reliability of the whole scale reached to 0.817, split-half reliability of each partial were between 0.758 and 0.793.The correlation coefficient among each dimensions were 0.267 to 0.569 (P<0.01) ,and the coefficient between each dimensions and the total score were between 0.671 and 0.857(P<0.01).Confirmatory factor analysis showed that three factor model was optimal (GFI =0.935, AGFI =0.902, NFI =0.907, CFI =0.936, IFI =0.935, RMSEA =0.050).The three dimensions and the total questionnaire had significant positive correlations with mental stress (r=-0.215--0.313, P< 0.01) and significant negative correlations with depression(r=0.319-0.602, P<0.01).Conclusion The recruits training burnout self-reported questionnaires meets the requirements of psychological surveying, and could be used to text recruits training burnout.
3.Self-asembled Gold Nanoparticles Coating for Solid-Phase Microextraction of Ultraviolet Filters in Environmental Water
Haixia LIU ; Yaoxia YANG ; Mingguang MA ; Xuemei WANG ; Xinzhen DU
Chinese Journal of Analytical Chemistry 2015;(2):207-211
Self-assembled gold nanoparticles ( AuNPs) coating was fabricated using an etched stainless steel wire as a support on which AuNPs were first deposited, then after modified with mercaptan, another layer of AuNPs was self-assembled. The AuNPs modified stainless steel wire was used in solid phase microextraction (SPME) coupled with high performance liquid chromatography (HPLC) for the determination of ultraviolet ( UV) filters in environmental water. The best extraction efficiencies were achieved within 30 min at 55℃ and at pH 7 with stirring rate of 800 r/min. Under the optimized conditions, the established AuNPs-SPME-HPLC method for the determination of UV filters benzophnone-3 ( BP-3 ) , 2-ethylhexyl-4-( N, N-dimethylamino ) benzoate ( OD-PABA) , 2-ethylhexyl-4-trimethoxycinnamate ( EHMC) and 2-ethylhexyl salicylate ( EHS) was linear in the range of 0. 004-200 μg/L. The limits of detection of the method were 0. 43-570 ng/L ( S/N=3 ) . The relative standard deviation ( RSD ) of AuNPs-SPME-HPLC was 1 . 9%-4 . 2% ( n=5 ) for spiked water samples of 20 μg/L each UV filter. In the case of real water samples analyses, the recoveries of spiked UV filters were 77 . 9%-108% with RSDs of 3 . 1%-8 . 0% ( n=5 ) .
4.Effects of glycosides of cistanche on focal cerebral ischemic rats
Xiaoyan JIANG ; Xiaowen WANG ; Xuefei WANG ; Fengxia LIU ; Xinzhen MENG ; Weijiang ZHU
Chinese Traditional and Herbal Drugs 1994;0(06):-
Object To study the protective effects of glycosides of cistanche (GCs) on focal cerebral ischemic rats. Methods Focal cerebral ischemia in rats was induced by 24 h occlusion of the middle cerebral artery (MCAO). The infarct area was measured by nitrobenzene thiocyanate (NBT) staining technique. The content of neurological deficits was evaluated by 0-11 scales. The activities of antioxidases and contents of MDA in ischemic brain tissue were analyzed. Results Significant decrease in infarct area and improvement in neurological deficits were observed by oral administration of GCs 125, 250 mg/kg, respectively. Significant increase in activities of SOD and GSH-Px, and significant decrease in contents of MDA in rats were also observed after 24 h MCAO. Conclusion GCs has a neuroprotective effect against focal cerebral ischemia and the effect may be related to the increase in activities of SOD and GSH-Px.
5.On-line Quantitative Monitoring and Control of Tobacco Flavors by Near Infrared Spectroscopy Combined with Advanced Calibration Transfer Method
Xinzhen SHI ; Zhiguo WANG ; Wen DU ; Hao YI ; Juan ZHANG ; Zengping CHEN ; Ruqin YU
Chinese Journal of Analytical Chemistry 2014;(11):1673-1678
Whennearinfraredspectroscopyisappliedtoon-linemonitoringandcontroloftobaccoflavors,the variation in temperature can severely deteriorate the predictive performance of near infrared spectroscopic calibration models and results in a significant increases of the root mean square error value for the main constituents in syrup samples from 2. 4% to 29. 0%. In this paper, near infrared spectroscopy has been incorporated with an advanced calibration transfer method-loading space standardization to effectively eliminate the deteriorate effects of temperature variation on quantitative results and finally realize the fast and accurate on-line quantitative monitoring and control of tobacco flavors. The root mean square error value for the main constituents in syrup samples is successfully retained at a satisfying low level of 3 . 8%. The results of this paper will provide technical support for the preparation, preservation and use of tobacco flavors, and realize on-line process quality control of cigarettes.
6.The intermediary and regulating effect of self-esteem on perceived stress and training burnout among accelerated plateau soldiers
Kui DING ; Yang YU ; Yan WANG ; Yongbing SONG ; Xinzhen MENG ; Tian QIN
Chinese Journal of Behavioral Medicine and Brain Science 2016;25(8):749-753
Objective To investigate the intermediary and regulating effect of self?esteem on per?ceived stress and training burnout among accelerated plateau soldiers. Methods A total of 700 accelerated plateau soldiers were investigated which were chosen by a random cluster sampling method,and assessed by the Perceived Stress Scale, Self?esteem Scale and Self?compiled Soldiers' Training Burnout Questionnaire. Results ( 1) The total score of training burnout,the score of physical and mental exhaustion and the score of training alienated among soldiers who had a history of training injury (27.85±5.80,14.89±3.46 and 6.89± 2.26,respectively) were significantly higher than those of soldiers who didn't have a history of training injury (25.05±5.12,12.68±3.25 and 6.16±2.78,respectively),and the differences were significant ( t= 4.321, 5.764,2.825,all P<0.01). The total score of training burnout,the score of physical and mental exhaustion and the score of training alienated among soldiers who had a high training expectation were higher than those of soldiers who didn't have a high training expectation,and the differences were significant (P<0.01). (2) Among accelerated plateau soldiers,training burnout showed significantly positive correlation with perceived stress ( r=0.323, P<0.01),and significantly negative correlation with self?esteem ( r=-0.409, P<0.01). (3) The intermediary role of self?esteem between perceived stress and training burnout was remarkable (P<0.01) ,which accounted for 33.8% of the total effect,and self?esteem also had a regulating effect (P<0.05) . Conclusion Radical plateau soldiers have remarkable differences due to the history of training injury or training expectations,and self?esteem has partial intermediary and regulating effect between perceived stress and training burnout.
7.Comparison of the role that poly hydroxy acrylic acid plays in the detection ofHER-2 gene in breast cancer by hematoxylin and eosin staining and fluorescencein situ hybridization with that of 4% neutral buffered formaldehyde
Zhiqiang CHEN ; Ying WANG ; Xianjun MI ; Ang CHEN ; Shoujun ZHONG ; Huayong HUANG ; Wentong DENG ; Chaofan LIU ; Xiumei XU ; Xinzhen DAI
China Oncology 2016;26(2):121-127
Background and purpose: Adequate tissue ifxation, transparent dewaxing is an important step of hematoxylin eosin (HE) staining and lfuorescence in situ hybridization (FISH) in detection of breast cancerHER-2 gene. The purpose of this study was to make a comparison between poly hydroxyl acrylic acid which is an environmen-tally friendly ifxation liquid and 4% neutral buffered formaldehyde in tissue ifxation for HE staining and FISH to detect theHER-2 gene in the breast cancer tissue sections. The study aimed to evaluate the feasibility of replacing 4% buffered formaldehyde, a traditional ifxation liquid, with the poly hydroxyl acrylic acid, an environmentally friendly ifxation lfuid.Methods:This project was performed on tissue samples collected from 69 cases of breast cancer, 41 cases of breast ifbroadenoma, 40 cases of uterine leiomyoma, 25 cases of cervical tissue, 25 cases of placenta obtained from the outpatient and inpatient departments of Zhongshan Boai Hospital from Mar. 2011 to Jan. 2015, from each of which two samples were drawn and two blocks of each specimen were divided into two groups randomly. Then one group was ifxed with 4% neutral buffered formaldehyde and made into 200 sections by HE while the other group was ifxed with poly hydroxyl acrylic acid and made into another 200 sections. The slice level of the two groups was determined by the staining condition of the sections, and SPSS 19.0 was employed to compare the excellent and good rate of HE staining. Additional 69 sections were produced with two groups of breast invasive ductal carcinoma tissues, and SPSS 19.0 was used to detect the ampliifcation ofHER-2 gene by FISH.Results:First, the number of best-quality slices stained with HE ifxed separately by poly hydroxyl acrylic acid and 4% neutral buffered formaldehyde was 155 and 166, respectively. The number of excellent pieces was 41 and 33, respectively, while the number of mediocre pieces was 3 and 1 with bad pieces being 1 and 0, respectively. The excellent and good rates of HE staining were 98% and 99.5%, respectively. There was no significant difference between the two groups (χ2=1.33,P>0.05).Second, the positive rates of the tis-sue slices by FISH ifxed separately by poly hydroxyl acrylic acid and 4% neutral buffered were 26.09% and 23.19%, respectively. There was no signiifcant difference between the two groups (χ2=0.50,P>0.05).Conclusion:The results obtained with HE staining and FISH using poly hydroxyl acrylic acid as a ifxation liquid are not signiifcantly different from those using 10% neutral buffered formaldehyde. Therefore, poly hydroxyl acrylic acid meets the requirements of environmental protection, and thus has the potential to be promoted and widely used.
8.Comparison between poly hydroxy acrylic acid and Van-clear replacing the tradi-tional reagents to detect the cervical hTERC genes by adopting FISH technique
Zhiqiang CHEN ; Ying WANG ; Xianjun MI ; Ang CHEN ; Huayong HUANG ; Shoujun ZHONG ; Wentong DENG ; Chaofan LIU ; Xiumei XU ; Xinzhen DAI
Journal of Peking University(Health Sciences) 2016;48(2):356-360
Objective:To observe the difference of the human telomeres RNA component (hTERC) genes’amplification in the cervical tissue by applying the environment-friendly fixative poly hydroxy acrylic acid and the transparent dewaxing solution Van-clear separately or jointly to replace the traditional fixative 4% (volume fraction)neutral buffered formalin and the conventional transparent dewaxing solu-tion xylene in the use of fluorescence in situ hybridization (FISH)for detection.Methods:In the study, 255 cases of cervical tissue specimens submitted by the Department of Gynecology in Zhongshan Boai Ho-sipital were collected from Mar.2013 to Apr.2015.Four samples were taken from the same lesion site. All the cases were divided into 4 groups and named group A,B,C,and D.Group A used 4% neutral buffered formalin fixed and xylene dewaxing to make slices.Group B used poly hydroxy acrylic fixed and xylene dewaxing to make slices.Group C used 4% neutral buffered formalin fixed and Van-clear trans-parent to make slices.Group D used poly hydroxy acrylic fixed and Van-clear transparent dewaxing to make slices.The amplification of hTERC genes in the four groups of cervical specimens was also detected by FISH technique.Results:When the hTERC genes were detected by FISH method under the fluore-scence microscope,it was obvious that the tissue profile and the background of group A,B,C and D were all clear.The probe was fixed in the accurate position so that the bright red or green fluorescence signals were easily found in these four groups.Compared with the positive rate of group A,there was no statistical significance in that of group B,C and D (P>0.05).At the same time,the coincidence rate of the FISH results was high,which showed that the new environment-friendly reagent had no significant difference in the detection of cervical hTERC genes by FISH technique.Conclusion:It is possible for the environment-friendly reagent poly hydroxy acrylic acid and Van-clear to replace 4%neutral buffered for-malin and xylene separately or jointly to detect the cervical hTERC genes by adopting FISH technique.
9.Application of polyhydroxy acrylic acid and Van-clear in the detection of EGFRgene mutations in non small-cell lung cancer by qRT-PCR method
Zhiqiang CHEN ; Ying WANG ; Caiguo YE ; Xianjun MI ; Ang CHEN ; Chao BI ; Chaofan LIU ; Xiumei XU ; Lifeng DUAN ; Yanfei GUAN ; Wentong DENG ; Xinzhen DAI
Journal of Xi'an Jiaotong University(Medical Sciences) 2017;38(5):758-762,767
Objective To compare two different methods to detect the differences of gene mutation rate, sensitivity, specificity and coincidence rate of epidermal growth factor receptor (EGFR) in non-small-cell lung cancer (NSCLC) so as to assess the clinical value of qRT-PCR method and its environmental-friendly technologyplatforms.One uses environmental fixative poly hydroxyl acrylic acid and green transparent liquid dewaxing Van-clear alone or in combination to replace the traditional fixative 4% (volume fraction) neutral buffered formalin and the traditional transparent dewaxing liquid xylene in application of quantitative real-time polymerase chain reaction (qRT-PCR).The other uses traditional reagents in direct sequencing.Methods We selected 91 cases of primary NSCLC specimens resected between May 2013 and March 2016 in Zhongshan Bo`ai Hospital and Zhongshan Hospital of Traditional Chinese Medicine.Five samples were taken from the same tumor lesion.We used a random number table to randomly divide these samples into Groups A, B , C, D, and E.Group A received direct sequencing method in detection of EGFR gene mutations.Besides, during the experiment, 4% neutral buffered formalin was used for fixing, and xylene transparent dewaxing was used to make slices for DNA extraction dewaxing.Group B received qRT-PCR method to detect EGFR gene mutations.Meanwhile, during the experiment, 4% neutral buffered formalin was used for fixing, and xylene transparent dewaxing was used to make slices for DNA extraction dewaxing.Group C received qRT-PCR method in detection of EGFR gene mutations.At the same time, during the experiment, polyhydroxy acrylic acid was used for fixing, and xylene transparent dewaxing was used to make slices for DNA extraction dewaxing.Group D received qRT-PCR method to detect EGFR gene mutations.In the meantime, 4% neutral buffered formalin was used for fixing, Van-clear transparent dewaxing was used to make slices for DNA extraction dewaxing.Group E received qRT-PCR method in detection of EGFR gene mutations.In addition, during the experiment, polyhydroxy acrylic acid was used for fixing, and Van-clear transparent dewaxing was used to make slices for DNA extraction dewaxing.In addition, during the experiment, polyhydroxy acrylic acid was used for fixing, and Van-clear transparent dewaxing was used to make slices for DNA extraction dewaxing.The mutations of Exons 18, 19, 20, and 21 in EGFR genes were respectively determined in the five groups of NSCLC.Results ① Groups B, C, D, E and A did not significantly differ in the percentage of people with mutations or target site mutation rates of EGFR genes in NSCLC (P> 0.05).② The detection results of EGFR target site mutation in Groups B, C, D, E and A had good sensitivity, strong specificity, and high compliance rate.Conclusion The green transparent liquid dewaxing Van-clear alone or in combination to replace the traditional fixative 4% neutral buffered formalin and the traditional transparent dewaxing liquid xylene in the application of qRT-PCR so as to detect EGFR gene mutations in NSCLC has good consistent results compared with the method that uses traditional reagents in direct sequencing.It has the significance and value in clinical application.
10.Efficacy and safety of MatrixRIB fixation system in the treatment of severe rib fractures
Jianpeng ZHANG ; Lin SUN ; Jun WU ; Lijie WANG ; Weiqiang LI ; Yanyu WANG ; Xinzhen LI
Chinese Journal of Geriatrics 2019;38(3):288-291
Objective To investigate the efficacy and safety of MatrixRIB fixation system in the treatment of severe rib fractures.Methods A total of 131 patients with severe rib fractures undergoing open reduction and internal fixation using MatrixRIB fixation system in our department were enrolled.Data including demographics,injury characteristics,surgical procedure details and postoperative recovery were collected.The operation experiences were summarized,and complications,postoperative and follow-up data were analyzed.Results Totally 637 (637/891)rib fractures were fixed.No internal fixation disorder was found,but 1 case had displacement after internal fixation.The majority of patients were extubated immediately after surgery.The mean time of pressure-support ventilation after surgery was 47.6(7 143)hours.The chest instability and pain were improved in all patients after surgery.At 3 to 6 months after treatment,70 patients(70/102)returned to work,and 87 patients(87/89)recovered previous normal life.Conclusions MatrixRIB fixation system is easy to operate in the treatment of severe rib fractures and has good clinical outcomes with few complications.Patients' pain is significantly relieved with satisfactory rehabilitation.