1.The effects of WeChat platform nursing intervention on complications of ear expanded skinflap among children
Haixia JIANG ; Fenghua YUAN ; Xinqi HOU ; Jintian HU ; Qingguo ZHANG
Chinese Journal of Practical Nursing 2016;32(23):1761-1764
Objective Comparative effect of WeChat platform nursing intervention and routine nursing intervention on reducing the incidence of complications of children skin expansion in the process of external ear reconstruction. Methods 132 cases of congenital microtia received skin expander implantation at our institution from Jan 2014 to Aug 20 14 were included as control group. 122 cases of congenital microtia received skin expander implantation at our institution from Sep 2014 to Apr 2015 were included as the intervention group. Children and their families in the control group were treated with routine propaganda and education, and the intervention group were added with internet nursing intervention. Collection and analysis the family health knowledge degree and the occurrence of complications in children of the two groups. Results The score of health knowledge about skin expansion in the intervention group was (33.67 ± 2.44),which was significant higher than that of in the control group (25.07 ± 2.02), t=9.71, P < 0.01. The incidence rate of complication in the intervention group was 2.46%(3/122), which was significant lower than that of in the control group, 8.33%(11/132),χ2=4.20, P<0.05. The satisfaction rate of patients′family member in the intervention group was 95.08%(116/122), which was significant higher than that of in the control group, 84.09%(111/132 ),χ2=15.65, P<0.05. Conclusions WeChat platform nursing intervention can reduce expansion flap complications occurrence rate in the periods of expander. It is worthy of clinical application.
2.Quantification of human urine and serum iodine by inductively coupled plasma mass spectrometry
Songlin YU ; Qian CHENG ; Jianhua HAN ; Weiyan ZHOU ; Xinqi CHENG ; Li′an HOU ; Ran GAO ; Wei SU ; Zhi LI ; Ling QIU
Chinese Journal of Laboratory Medicine 2016;39(12):917-921
Objective This paper aims at establishing a inductively coupled plasma mass spectrometry ( ICP-MS) method for quantification and evaluation of iodine in human urine and serum in routine clinical laboratory .Methods This study was methodology validation research on iodine evaluation using ICP-MS.Ammonia, isopropanol and ultrapure water were mixed at certain ratio to dilute samples in the ratio of 1:10, and then the diluted samples were analyzed by ICP -MS.Re was used as the internal standard.And linearity, lower limit of detection, recovery, precision, accuracy, carryover and stability was evaluated thoroughly .Results of iodine of pregnant women who required iodine tests were retrospectively analyzed to evaluate the status of iodine .Results The method only needs 30s for analysis of one sample .It was sensitive with a lower limit detection of 0.87μg/L, the correlation coefficient was higher than 0.999 9 in ten measurements.The recovery in both serum and urine was approximately 100% (95.3% -109.9%). Based on the NIST standard reference material 3668 comparison, the bias was less than 4%( -0.9% -3.9%).The inter-coefficient variation (CV) for serum iodine and urine iodine was 1.2%-3.0%, 2. 0%-2.9%, respectively;and total CV for serum iodine and urine iodine were 3.0%-3.8%, 4.1%-4.9%, respectively.The mean carryover of this method was 0.03% and iodine was stable for at least one month at -20℃ and 4℃.The urine and serum iodine for pregnant women was (154.8 ±89.7) μg/L (mean ±SD),(75.8 ±21.4) μg/L, respectively.The correlation between urine and serum iodine was 0.21. Conclusion Establishe a rapid and simple ICP -MS method for urine and serum iodine measurement with high accurate and precise in routine clinical laboratory .
3.Investigation on the Consistency of Five Measurement Systems for Serum Lipids
Qian DI ; Ling QIU ; Lian HOU ; Jun DONG ; Fang ZHAO ; Pengchang LI ; Kai WANG ; Xinqi CHENG ; Xiuzhi GUO
Journal of Modern Laboratory Medicine 2016;31(3):36-42,47
Objective To explore achieving the consistent method of blood lipid examination by comparing the results of 5 dif-ferent blood lipid detection system commonly used in the use of refernce method to assign freach blood serum before and af-ter calibration.Methods Used the indoor quality control total variation (CV%)to evaluate the 5 blood lipid examination system of the imprecision.Referenced the United States Clinical and Laboratory Standardization Institution (CLSI)9A2 EP program,compared with 54 fresh blood serum in 5 commonly used examination system of Total Cholesterol (TC)and Tri-glyceride (TG),and then estimated the bias between the different detection systems and mean value.8 of the samples were determined by the reference method and estimate the bias of different system.The fresh frozen serum samples assigned by reference method were used to evaluate the above examination system,then compare and estimate the bias again with the same 54 fresh serum samples.Compared the variation of 54 samples in different detection system before and after calibra-tion.Results The TG imprecision of 5 examination system were between 3.76%~23.65%,the TC imprecision between 2.19%~23.43%,that mean the results were good,the r value of TG were between 0.996 7~0.999 6 and the TC were 0.956 2~0.996 7.But there were obvious differences between the results of the systems,and the biggest difference were 14.72%~34.21% in TG and 3.11%~14.57% in TC.After use the serum assignment by reference method,the variation of the systems has been significantly decreased.Conclusion Using the reference method to assign the fresh serum of different blood lipid detection system can effectively improve the consistency of the results.
4.Negative interference by calcium dobesilate in uricase-peroxidase coupled assays of serum uric acid
Xiuzhi GUO ; Jiangtao ZHANG ; Li′an HOU ; Jie WU ; Songlin YU ; Huiling FANG ; Xinqi CHENG ; Liangyu XIA ; Lin ZHANG ; Zhihong Qi ; Shuling CHI ; Dawei TONG ; Yingyin HAO ; Ling QIU
Chinese Journal of Laboratory Medicine 2015;(9):600-604
Objective To assess the interference by calcium dobesilatein 7 peroxidase-baseduric acid assays and to determine its clinical significance.Methods In the in vitro experiments, uric acid in pooled serum with final concentrations of calcium dobesilate additions (0, 2, 4, 8, 16, 32, and 64μg/ml) were measured by 7 peroxidase-based assays.Percent Bias (%) was calculated relative to the drug-free specimen.In the in vivo experiments, changes in serum uric acid and calcium dobesilate concentrations were observed before and after calcium dobesilate administration ( baseline, 0 h, 1 h, 2 h, 3 h, 4 h, 6 h ) involunteers.The interference in different assays was assessed compared with LC-IDMS/MS method. Calcium dobesilate levels in 40 specimens from those taking calcium dobesilate were measured by HPLC method.Of the 40 specimens, 10 were selected to analyse the levels of uric acid by both peroxidase and UV measurement method to assess the impact in clinical status.Results In the in vitro study, concentrations of uric acid measured by 7 peroxidase-based assays were reduced by -6.3%to -21.2%compared with drug-free serum, when theconcentration of calcium dobesilate was16μg/ml.In the in vivo study, comparedto UA levels at 0 h, the biasesof serum uric acid determined by peroxidase method after calcium dobesilate administration(1 h, 2 h, 3 h, 4 h, 6 h) were of -3.33%, -6.79%, -7.49%, -6.07%, -4.09%, respectively.The observed uric acid concentrations for 8 participants measured by enzymatic assays were inhibited by -3.75% to -6.89% at 0 hour and by -16.9% to-22.22% at 2 hours relative to the concentrations measured by the LC-IDMS/MS method. Conclusions Calcium dobesilate produced a clinically significant negative interference with uric acid in all peroxidase-based uric acid assays,which may result in false evaluation of uric acid level in clinical status.Significant differences in the degree of interference were observed among the assays.
5.Performance verification of six enzymatic glycated albumin reagents
Yicong YIN ; Fang ZHAO ; Li′an HOU ; Songlin YU ; Honglei LI ; Xiuzhi GUO ; Jie WU ; Tingting YOU ; Xinqi CHENG ; Qian CHENG ; Ling QIU
Chinese Journal of Laboratory Medicine 2017;40(6):436-442
Objective To validate the performance of six enzymatic glycated albumin reagents and evaluate their clinical application.Methods The performance of six enzymatic glycated albumin reagents(labled as A,B,C,D,E,F) from Beijing Jiuqiang Co, Beijing Lideman Co,Ningbomeikang Co, Beijing Haomai Co, Sichuan Maike Co and Asahi Kasei Co were assessed on Olympus AU5800 automatic biochemistry analyzer.According to the standard of CLSI,the precision,interference and linear correlation of these reagents were assessed.To assess the accuracy of GA% ,we used GA standard material whose value had been assigned using ID-LC/MS method provided by ReCCS.To do the method comparison and determine the consistency of assay, 50 fresh serum samples of T2DM outpatient and 80 fresh serum samples of apparently healthy people in Jan 2016 were tested using six kits.According to the EP28-A3C protocol, the reference range for GA%was validated in 122 apparently healthy individuals undertaking medical examination from January to February 2016 in PUMC.Results The precision,and the ability of anti-interference of the six reagents were good.The accuracy percentage deviation of six reagents was-19.3%-9.2%.The correlation coefficient of domestic reagents A to E and imported reagents F in the determination of GA% was 0.966-0.999, the average absolute bias was 7.0%-10.4%.The coincidence rate of A-E and F in determining abnormal GA% was between 88.5% and 96.9%.The coincidence rate was increased after switching to the reference range for preliminary clinical evaluation.Conclusion Six GA enzymatic kits used in automatic biochemical analyzer have high precision and strong anti-interference ability.Accuracy still needs to be improved.
6.Survey of vitamin D status in apparently healthy younger and elder adults
Ruiping ZHANG ; Songlin YU ; Xinqi CHENG ; Liangyu XIA ; Qian CHENG ; Jianhua HAN ; Xuzhen QIN ; Pengchang LI ; Li'an HOU ; Ling QIU
Chinese Journal of Laboratory Medicine 2017;40(9):689-692
Objective To analyze the vitamin D status among apparently healthy younger and elder adults in Beijing based on liquid chromatography tandem mass spectrometry.Methods This is an observational study.Participants included 287 apparently healthy young adults(143 males and 144 females) with an average of (32.2 ± 6.9) years old (19-44 years).At the same time 198 middle-and elder-aged adults were recruited [90 males,108 females,(55.6 ± 7.6) years],and fasting blood samples were collected and serum were isolated.They measured 25-hydroxyvitamin D (25OHD:25OHD2 and 25OHD3)using liquid chromatography tandem mass spectrometry method.Vitamin D with deficiency,insufficiency,sufficiency and intoxication was categorized as 25OHD < 20 ng/ml,20-30 ng/ml,30-150 ng/ml,and ≥ 150 ng/ml,respectively.ALT,Ca,P,Cr,Glu,TG,TC and iPTH wereanalyzed using automatic analyzers.Statistical analysis was performed using SPSS17.0.Results The median 25OHD level in the total studied younger adults was 16.0 [2.5%-97.5%:(6.1-29.0) ng/ml] which didn't show significant difference with that of middle-and elder-aged adults.Younger males had significant higher level of 25OHD than females [17.9 (8.3-32.3) ng/ml vs.14.4 (5.4-26.4) ng/ml,Z =-4.238,P < 0.01].Of the total younger subjects,the rate of vitamin D with deficiency (< 20 ng/ml),insufficiency (20-30 ng/ml)and sufficiency (≥30 ng/ml) was 72.8%,25.1%,2.1%,respectively,while that of middle-and elderaged adults was 76.3%,21.2%,2.5% respectively,and that of younger males was 65.0%,30.8%,4.2%,respectively while that of younger females was 80.6%,19.4%,0%,respectively.Younger females had significantly higher rate of 25OHD deficiency (x2 =31.766,P < 0.01).With adjusting sex,age and BMI,serum iPTH (r =-0.264,P < 0.01) was significantly negatively correlated with 25OHD while Cr (r =0.221,P < 0.01) showed significantly positively correlation with 25OHD.Conclusion Vitamin D deficiency is prevalent in both younger and elder adults in Beijing,especially in younger females.
7.Survey for variation of prevalence of hyperuricemia and its correlations with blood glucose and lipid in healthy adults receiv-ing physical examination at Peking Union Medical College Hospital from 2012 to 2017
Danchen WANG ; Yicong YIN ; Songlin YU ; Xiuzhi GUO ; Lian HOU ; Honglei LI ; Tingting YOU ; Qian CHENG ; Shaowei XIE ; Xinqi CHENG ; Liangyu XIA ; Ling QIU
Chinese Journal of Clinical Laboratory Science 2018;36(6):462-466
Objective To investigate the changes of prevalence of hyperuricemia ( HUA) and its correlations with blood glucose and lipid in healthy adults receiving physical examination at Peking Union Medical College Hospital (PUMCH) from 2012 to 2017. Meth-ods An observational approach was adopted for the data analysis.The test results of uric acid (UA),fasting blood glucose (FBG),to-tal cholesterol (TC),triacylglycerol (TG),low density lipoprotein cholesterol (LDL-C),high density lipoprotein cholesterol (HDL-C), creatinine (Cr) and Urea of 399 089 cases (206 881 males and 192 208 females) at PUMCH from January 2012 to December 2017 were collected and statistically analyzed.Results The total prevalence of HUA was 17.4% in which the prevalence of males was signif-icantly higher than that of females (25.6% vs 8.5%,χ2=20 234.850,P<0.01).During the years of 2012 to 2017,the prevalence of HUA was 26.5%,24.7%,28.6%,23.9%,24.8% and 24.5% in males,and 13.8%,6.3%,7.9%,6.1%,6.2% and 6.8% in females for each year respectively.The prevalence of HUA in males aged 18 to 64 years old was significantly higher than that in the age-matched fe-males (all P<0.05).However, the prevalence of HUA in males aged≥65 years old was similar to the age-matched females.There was no statistically significant difference of HUA prevalence between males and females aged ≥65 in 2013,2015,2016 and 2017 ( χ2=1.792,0.017,1.440 and 0.205 respectively;all P>0.05).The percentages of hyperlipidemia in both males and females of HUA group were higher than those of non-HUA group respectively (all P<0.01).The percentage of hyperglycemia in males of non-HUA group was higher than that of HUA group,but the percentage of hyperglycemia in females of non-HUA group was lower than that of HUA group ( all P<0.01).High levels of TC,TG and FBG were risk factors of HUA with increased OR values in increased concentrations of TC,TG and FBG,respectively.Conclusion During the recent 6 years, in healthy adults receiving physiced examination at PVMCH, the preva-lence of male HUA diagnosed was at overall high level,but the prevalence of female HUA was in decreasing and relatively stable trend. Hyperlipidemia and hyperglycemia should be the risk factors of HUA.
8.Comparison of Six Automated Immunoassays With Isotope-Diluted Liquid Chromatography-Tandem Mass Spectrometry for Total Thyroxine Measurement
Songlin YU ; Weiyan ZHOU ; Xinqi CHENG ; Qinghui MENG ; Honglei LI ; Li'an HOU ; Jun LU ; Shaowei XIE ; Qian CHENG ; Chuanbao ZHANG ; Ling QIU
Annals of Laboratory Medicine 2019;39(4):381-387
BACKGROUND: Accurate serum total thyroxine (TT4) measurement is important for thyroid disorder diagnosis and management. We compared the performance of six automated immunoassays with that of isotope-diluted liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) as the reference method. We also evaluated the correlation of thyroid stimulating hormone (TSH) with TT4 measured by ID-LC-MS/MS and immunoassays. METHODS: Serum was collected from 156 patients between October 2015 and January 2016. TT4 was measured by immunoassays from Abbott (Architect), Siemens (ADVIA Centaur XP), Roche (E601), Beckman-Coulter (Dxi800), Autobio (Autolumo A2000), and Mindray (CL-1000i), and by ID-LC-MS/MS. Results were analyzed using Passing-Bablok regression and Bland-Altman plots. Minimum requirements based on biological variation were as follows: a mean bias of ≤4.5% and total imprecision (CV) of ≤3.7%. RESULTS: All immunoassays showed a correlation >0.945 with ID-LC-MS/MS; however, the slope of the Passing-Bablok regression line varied from 0.886 (Mindray) to 1.23 (Siemens) and the intercept from −12.8 (Siemens) to 4.61 (Mindray). Only Autobio, Beckman-Coulter, and Roche included the value of one in the 95% confidence interval for slope. The mean bias ranged from −10.8% (Abbott) to 9.0% (Siemens), with the lowest value noted for Roche (3.5%) and the highest for Abbott (−10.8%). Only Abbott and Roche showed within-run and total CV ≤3.7%. CONCLUSIONS: Though all immunoassays correlated strongly with ID-LC-MS/MS, most did not meet the minimum clinical requirement. Laboratories and immunoassay manufacturers must be aware of these limitations.
Bias (Epidemiology)
;
Diagnosis
;
Humans
;
Immunoassay
;
Mass Spectrometry
;
Methods
;
Thyroid Gland
;
Thyrotropin
;
Thyroxine
9.Application of WeChat platform on health education of patients with external ear reconstruction
Haixia JIANG ; Fenghua YUAN ; Xinqi HOU ; Jintian HU ; Qingguo ZHANG
Chinese Journal of Modern Nursing 2016;22(11):1503-1506
Objective To explore the effects of health education based on WeChat platform to reduce external ear reconstruction complications through skin quantitative expansion method.Methods A number of 254 congenital microtia patients and their families admitted from January to August 2014 were treated as control group who received routine health education.A total of 238 cases patients with the same disease and their families admitted from September 2014 to April 2015 were chosen as observation group who received routine and WeChat platform for health education.Water injection nurses collected the data of patients' health knowledge mastering degree,comparing two groups of patients and families disease knowledge mastering degree,complication rates and nursing satisfaction.Results Patients and families in observation group grasped health knowledge better than that of control group,with a lower complication incidence than that of control group(P <0.01).After the interventions of health education,the satisfaction was 94.96% in the observation group comparing with 83.46% in the control group (P < 0.01).Conclusions Nursing intervention based on WeChat platform can reduce the incidence of expanded skin flap complications,improve patient and families' nursing knowledge and elevate nursing satisfaction.
10.Investigated the prevalence of hypouricemia in Peking Union Medical College Hospital
Yicong YIN ; Jie WU ; Songlin YU ; Li'an HOU ; Xiuzhi GUO ; Tingting YOU ; Dandan LI ; Danchen WANG ; Qian CHENG ; Xinqi CHENG ; Ling QIU
Chinese Journal of Laboratory Medicine 2018;41(3):237-241
Objective To investigate the prevalence and possible factors of hypouricemia in Peking Union Medical College Hospital.Methods A retrospective investigation.Serum uric acid, lipids, glucose and other chemistry tests were analyzed among 83176 outpatients(Male:30795,Female:52381), 15849 inpatients(Male:7402,Female:8447)and 24081 healthy subjects(Male:11859,Female:12222)in Peking Union Medical College Hospital from December 2015 to April 2016.Grouped by gender and age, the prevalence of hypouricemiawas analyzed in all subjects and the etiology and possible risk factors of hypouricemia were explored among all patients.Results The serum uric acid of outpatients,inpatients and healthy subjects were 286(235-348)μmol/L, 282(226-348)μmol/L and 298(244-358)μmol/L, respectively.And the prevalence were 0.6%(499/83176),2.5%(390/15849)and 0.2%(39/24081), respectively.The prevalence of hypouricemia ofwomen was significantly higher than that ofmen(outpatients:0.7%vs 0.4%,P<0.001;inpatients:2.8%vs 2.1%,P=0.004;healthy subjects:0.30%vs 0.04%, P<0.001).After analyzing 507 hypouricemia patients, the top three clinical diagnoses that related with hypouricemia were kidney diseases, tumor and rheumatic diseases.Compared with the control group, the prevalence of hypouricemia in hypertriglyceridemia group and group with eGFR higher than 90 ml/(min· 1.73 m2)were lower(OR:0.33, 95% CI:0.21-0.50; OR:0.16, 95% CI:0.09-0.29), and the prevalence of hypouricemia in hyperglycemia group was higher(OR:1.62, 95% CI:1.12-2.35). Conclusion The prevalence of hypouricemia of Chinese women was higher than that of men and may be related with TG,Glu and eGFR.