1.Effects of total glucosides of paeony(TGP) on immune system
Chinese Journal of Pathophysiology 1989;0(06):-
The hemolysin (IgM) production by mouse splenic lymphocytes immunized with sheep red blood cell in vitro was enhanced by lower concentrations (0.1-0.4?g/ml) of total glucosidcs of pacony (TGP), but diminished by higher concentrations (0.4-3.2?g/ml) of the drug. The dual effects of TGP on ConA induoed proliferation of mouse splenocytcs was also observed by in vitro treatment with TGP over a range of 0.05-1.6?g/ml. These results suggested that effects of TGP on immune system was definitely depend on the concentrations of TGP administered.The specific helper T (Th) cclls were induced by irradiation with ~(60)Co at 800R plus primed thymocytes and were measured by the adoptiver transfer system. It was found that the higher generation of Th cells incroosed further by TGP (5mg/kg, ip).
2.The Diagnostic Value of Colonoscopy Compared with Colon Double Contrast Radiography to Colon Carcinoma
Journal of Practical Radiology 2001;0(01):-
Objective To evaluate the value of diagnose of colon carcinoma by colonoscopy and double contrast radiography.Methods The results and data of radiography diagnosis,colonscopy diagnosis,biopsy and post-operation pathology were analyzed retrospectively.Results The rate of accordance by X-ray diagnosis was 85.4%,colonscopy 80.5% and biopsy 84.6%.Conclusion The method of examination of colon double contrast radiography preceeds to colonoscopy examination when the patients were suspected suffering from the right colon or left colon carcinoma accompanying by masses;colonoscopy is the first method of diagnosis to choose when the patients were suspected suffering from carcinoma of sigmoid colon or colon polyps undergoing malignant changes.
3.Effects of captopril on free radical production and it's immune function
Chinese Journal of Pathophysiology 1986;0(02):-
Captopril (CPT, 40, 80mg/kg, ig) enhanced serum superoxide dismutaseactivity, and suppressed luminal-dependent chemiluminescence of peritoneal macrophagesin mice. CPT (160mg/kg, ig) had a suppressive action on lipid peroxidation of mice. Theseresults suggested that CPT had antioxygen free radical effect or anti-lipid peroxidationeffects. CPT at 25 ?g/ml concentration suppressed ConA-induced prolifeation of mousesplenic T lymphocytes in vitro, which suggested that CPT had a suppressive effct on Tlymphocyte function.
4.Electrochemiluminescence Performance of Poly(aniline_luminol) Composite Nanowires Synthesized by Chemical Oxidation
Yanjie WANG ; Guixin LI ; Xingwang ZHENG
Chinese Journal of Analytical Chemistry 2015;(1):141-145
Poly ( aniline_luminol ) composite nanowires were synthesized by chemical oxidation using ammonium peroxydisulfate. In contrast to the maximum fluorescence emitting wavelength of luminol at 425 nm, the maximum fluorescence emitting wavelength of the polymeric luminol in the composite nanowires was red shifted to 465 nm obviously. The poly ( aniline_luminol) composite nanowires were modified on graphite electrode surface by drop coating, forming a stable poly ( aniline_luminol ) composite nanowires film. The composite nanowires film modified electrode presented favorable electrochemiluminescence ( ECL ) performances, and the ECL response could be enhanced by hydrogen peroxide. Under the optimized experimental conditions, the modified electrode provided a linear range of 5. 0×10-9-1. 0×10-5 mol/L for the detection of hydrogen peroxide with a detection limit of 2 ×10-9 mol/L.
5.Expression and significance of tumor suppressor gene PTEN in colorectal cancer
Guobao ZHENG ; Yuanhe WANG ; Chunfang GAO ; Hongyang WANG ; Xingwang WAN
Chinese Journal of General Surgery 2001;0(10):-
Objective To investigate the role of tumor suppressor gene PTEN in colorectal cancer. Methods Using Northern blot,immunohistochemistry, colorectal carcinoma was examined in 47 cases. ResultsKG1 The expression of PTEN mRNA in colorectal cancer was lower than that in paired para-carcinoma tissues( P
6.Evaluation of monochromatic imaging spectal CT for intestinal bleeding using an experimental pig intestine model
Wendong LIU ; Xingwang WU ; Bin LIU ; Hongwen LI ; Bin WANG
Chinese Journal of Radiology 2014;48(7):594-598
Objective To discuss the diagnostic value of monochromatic energy image spectral CT in active small bowel bleeding and to screen the optimal energy level that indicates active bleeding of the gastrointestinal tract.Methods The bleeding model was established using the small intestines of pigs in vitro.Seven blood flow rates were simulated:0.500,0.400,0.300,0.200,0.100,0.050,0.025 ml/min,respectively.For each rate,a GE Discovery HD750 CT scanner was used in GSI scan mode and 64 slice CT was performed,with a delay of 15 s and 40 s simulated the arterial phase and portal venous phase,respectively.Each out of the blood flow rate in the 2 modes was respectively scanned 5 times.The GSI reconstruction platform was employed to obtain 7 monochromatic energy images(40,50,60,70,80,90,100 keV).A set of polychromatic energy images was obtained from an ordinary scan.The detection rates of the contrast agent exudation regions using the two scanning methods were compared.The contrast to noise ratios(CNR) for the contrast agent exudation regions were measured.Randomized block analysis of Variance was performed to compare the differences in CNR between energy levels.The x2 test was used to compare the detection rates obtained from the 2 scanning methods.Results The detection rates for energy spectral CT and 64 slice CT in the arterial phase were 31/35 and 23/35,respectively; there was significant difference(x2=5.185,P=0.023).The total detection rates of portal venous phase were 35/35 and 32/35,respectively,there was no significant difference(x2=l.393,P=0.238).On the ordinary scan mode,the detection rates of arterial and portal venous phase difference was statistically significant(x2 =6.873,P =0.009);but on the GSI scan mode,there was no significant difference(x2=2.386,P=0.122). The CNR values at 8 group energy levels for arterial phase and portal venous phase were statistically different(respectively P< 0.05),the CNR value of the contrast agent exudation regions at 50 keV and 60 keV monochromatic energy images on the GSI scan mode higher than that of polychromatic energy images,the difference was statistically significant(respectively P<0.05),the CNR in portal venous phase images were higher than that of arterial at all energy groups,differences were statistically significant(t=-3.996 to-2.380,respectively P< 0.05).Conclusions Monochromatic energy image spectral CT demonstrates superiority over polychromatic energy images in detecting active bleeding of the gastrointestinal tract.The optimal monochromatic energy value for detection was between 50 keV and 60 keV,and the detection was easier in the portal venous phase than in the arterial phase.
7.Imaging presentations of multiple gastric duplication cysts inside the mediastina
Wendong LIU ; Bin LIU ; Xingwang WU ; Wanqin WANG
Chinese Journal of Digestive Surgery 2013;(4):307-309
Gastrointestinal duplication cyst is a rare congenital disease which can occur in any part of the digestive tract between the root of tongue and the anus,and it is commonly seen in the ileum.About 45% of the gastrointestinal duplication cyst occurs in the ileocecus and the epityphlon.Multiple gastric duplication cyst is a rare type of the gastrointestinal duplication cyst,which accounted for 3.8%-5.0%.Gastric duplication cyst mostly occurs in the greater curvature of the stomach,and it connects with the stomach wall.Multiple gastric duplication cysts in the mediastina is rarely seen.In this article,the imaging presentations of 1 patient with multiple gastric duplication cysts inside the mediastina were analyzed.
8.Investigation on the value of spectral CT imaging in diagnosis of benign and malignant thyroid nodules
Hongwen LI ; Bin LIU ; Xingwang WU ; Wanqin WANG ; Wendong LIU
Chinese Journal of Radiology 2014;48(2):100-104
Objective To explore the value of gemstone spectral imaging (GSI) in the detection and differential diagnosis of benign and malignant thyroid nodules.Methods The spectral CT images in 88 patients with thyroid nodules were analyzed retrospectively.All the patients underwent spectral CT scanning,including 33 patients undergoing biphase enhanced CT imaging.Nodules were divided into benign and malignant ones according to histopathologic results.The iodine concentration,slope of spectral curve,effective atomic number in non-enhanced and enhanced scanning were compared between benign and malignant group by the Wilcoxon rank sum test,respectively.The optimal iodine concentration threshold to predict malignancy was obtained by receiver operating characteristic curve (ROC),sensitivity and specificity were achieved.Results A total of 106 nodules were detected,including 76 benign and 30 malignant nodules.In non-contrast CT imaging,the average iodine concentration,slope of spectral curve,effective atomic number of were 2.35 × 100 μg/ml,0.29 and 7.71 for benign group:-0.51 × 100 μg/ml,-0.06 and 7.52 for malignant group (Z value were-3.072,-3.107 and-3.055,respectively ; P < 0.05).In the arterial phase,the average iodine concentration,slope of spectral curve,effective atomic number of the two group were 27.22 × 100 μg/ml,3.23 and 9.10 for benign group; 18.81 × 100 μg/ml,2.24 and 8.69 for malignant group (Z value were-2.582,-2.582 and-2.564,respectively; P < 0.05).In venous phase,no significant difference was found for each parameter between the two groups (P > 0.05).The optimal iodine concentration to predict malignancy was-0.35 × 100 μg/ml in non-enhanced phase with 56.7% sensitivity and 73.7% specificity.The optimal iodine concentration was 22.91 × 100 μg/ml in arterial phase,with 76.2% sensitivity and 75.0% specificity.Using iodine concentration to predict malignancy in both noncontrast phase and arterial phase,the sensitivity and specificity were 81.2% and 73.3%,while the accuracy was 81.6%.Conclusion Gemstone spectral CT imaging can quantitatively evaluate the iodine content of thyroid nodules,having a potential value in differential diagnosis of thyroid nodules.
9.Recent progress in the studies on taxol
Jinhui YUAN ; Lixia GUO ; Xingwang WANG ; Hong XIE
Chinese Pharmacological Bulletin 2001;17(2):135-139
Taxol could induce tumor cell apoptosis throug h activation of Fas/FasL and caspases. bcl-2 also played an important role in t axol-induced cell apoptosis. Furthermore, taxol had the similar action with lip opolysaccharide on inducing the release of bioactive substances including tumor necrosis factor, interleukin and nitric oxide. There were as well some progresse s in taxol-resistance of tumor cells.
10.Clinical Value of 64-slice Computed Tomography in the Diagnosis of Complex Congenital Heart Disease
Gengwu LI ; Bin LIU ; Wanqin WANG ; Xingwang WU ; Hong ZHAO
Journal of Practical Radiology 2010;26(2):183-188
Objective To study the clinical value of 64-slice spiral computed tomography(64SCT) contrast-enhanced scan and three-dimensional reconstructed techniques in the diagnosis of complex congenital heart disease(CCHD). Methods 39 patients with CCHD underwent CT angiography and transthoracic echocardiograms (TTE). Of them, the electrocardiographic-gating technique was used in 8 cases. The accurate rates in diagnosing CCHD with CT, TTE and CT with or without electrocardiographic-gating were analysed compared with that of operation and χ~2 test using SPSS13.0 tool. Results A total of 102 cardiac deformities con-firmed by operations,those included 47 intracardiac deformities,the diagnostic accuracys with CT and TTE were 85.1% and 95.7%, respectively, and there was no obvious difference among them (χ~2=2.68, P>0.05). 55 extracardiac deformities, the definite diagnos-tic rates with CT and TTE were 98.2% and 78.2%, respectively. CT was superior to TTE in the indentification of extracardiac de-formities(χ~2= 14.64 ,P<0.01). There was no obvious difference between with and without electrocardiographic-gating technique during CT scanning in diagnosis of cardiac deformities(χ~2=1.84, P>0.05). Conclusion 64SCT has significant value in diagnosis of CCHD,and there was no obvious difference in diagnosis of cardiac deformities by 64SCT between with and without electrocardio-graphic-gating technic.