1.Hidden blood loss in total knee arthroplasty under high negative pressure drainage
Changchun YU ; Minglu YANG ; Xingsheng DU
Chinese Journal of Tissue Engineering Research 2013;(48):8313-8318
BACKGROUND:Usual y, amount of bleeding during replacement and drainage amount after replacement were recorded to evaluate the amount of bleeding in patients with arthroplasty. These are dominant blood loss. Studies demonstrated that recessive blood loss exceeded 50%of total amount. OBJECTIVE:To compare the blood loss during total knee arthroplasty under high negative pressure drainage and common negative pressure drainage and to assess the effect of high negative pressure drainage on hidden blood loss in total knee arthroplasty.
METHODS:A total of 60 patients undergoing lateral total knee arthroplasty were equal y divided into high negative pressure drainage group and conventional drainage group (control group). We calculated the total blood loss (dominant blood loss and hidden blood loss) and blood transfusion amount with the Gross equation. The recovery after surgery and complications were compared.
RESULTS AND CONCLUSION:In high negative pressure drainage group, the total blood loss was (646±184) mL and the hidden blood loss was (215±128) mL. In the control group, the total blood loss was (867±296) mL and the hidden blood loss was (457±268) mL. The total blood loss and hidden blood loss in the high negative pressure drainage group were significantly less than those in the control group (P<0.05). The average blood transfusion amount was 224 mL in the high negative pressure drainage group and 467 mL in the control group. Fol owing unilateral total knee arthroplasty, total blood loss, hidden blood loss and blood transfusion amount after arthroplasty were less in the high negative pressure drainage group than those in the control group. In particular, the decrease in hidden blood loss was helpful to observe and treat the pathogenetic condition and to avoid potential risk, and benefits the recovery of knee joint function after surgery.
2.PERCUTANEOUS BALLOON PULMONARY VALVULOPLASTY(PBPV)
Xingsheng YANG ; Tingshu YANG ; Guangyi WANG ; Jingping SUN ; Weiru GONG ; Luoshan DU ;
Medical Journal of Chinese People's Liberation Army 1982;0(03):-
This paper reported the results of balloon pulmonary valvuloplasty for 8 patients (single-balloon for 7 cases,double-balloon for 1 case).The meanpulmonary valve orifice in diameter (PVOD) was dilated from 8.4?2.2 preoperation to 16.4?1.5mm of postoperation,the systolic pressure in rightventricle (RV)was reduced from 16.9?5.3 to 9.1?3.8kPa,the pressure gradient from RV to pulmonary artery was reduced from 14.9?5.1 to 6.6?2.9 kPa,the cardiac index was increased from 3.2?0.3 to-5.1?0.7L/min m-2.The symptoms and heart murmur were nearly,subsided after treatment,the patients dischargd within 5 days after operation.PBPV is a nonoperative procedure with good efffect and.safety.