1.Effect of spinal anesthesia on serum troponin T in the elderly patients during the perioperation
Zhou ZHANG ; Changchun ZHANG ; Ping WU ; Xinfa CHEN ; Liangjie ZHENG
Chinese Journal of Primary Medicine and Pharmacy 2009;16(3):484-486
Objective To explore the security of spinal anesthesia by observing the pefioperation serum troponin T in the elderly patients with coronary heart disease who underwent spinal anesthesia.Methods 40 case8 were divided into two groups according to the elderly patients with or without the history of coronary heart disease.Group Ⅰ 0f 20 cases were the patients with the history of coronary heart disease.Group Ⅱ of 20 cases were the patients without the history of coronary heart disease.Both groups were undertaken single spinal anesthesia combined with epidural anesthesia.The blood samples were collected at the time of perioperation,the end of the operation and 24 hours after surgery.The serum troponin T Was tested by Roche fully automated ehemiluminescent analyzer E170.The symptoms and signs of the coronary heart disease in the patient were observed.And the age,operation time,anesthesia lever,the amount of bleeding and transfusion were recorded,and at the same time,electrocardiogram,heart rate,pulse,cerebral oxygen saturation were monitored.Results There was no significant difference between two groups in age,operation time,anesthesia lever,the amount of bleeding and transfusion,heart rate,pulse,cerebral oxygen saturation.There was no significant difference between two groups in seram troponin T.No symptoms and signs of the coronary heart disease were observed in two groups.There Was no significant difference between two groups in constituent ratio of positive rate of serum troponin T.There was one case in each group that serum lroponin T was more than reference value (0.010μg/L)during the perioperation while the patient was no discomfort.Conclusion Spinal anesthesia has no impact on the change of perioperative 8ertlm troponin T in the elderly patients with coronary heart disease.
2.Virtual touch tissue imaging quantification in differential diagnosis of benign and malignant TI-RADS 4 thyroid nodules
Songnian WU ; Jiandi HE ; Tianan JIANG ; Liyun ZHONG ; Xinfa ZHANG
Chinese Journal of Ultrasonography 2016;25(7):573-578
Objective To observe the value of virtual tough tissue imaging quantification (VTIQ) in differential diagnosis of thyroid imaging reporting and data system(TI-RADS) 4 thyroid nodules.Methods A total of 185 patients with 192 TI-RADS 4 nodules were included in this study.The nodules were divided into three groups according to the maximum size as follows:Group Ⅰ,the maximum size≤0.6 cm;Group Ⅱ,0.6 cm< the maximum size≤ 1.0 cm;Group Ⅲ,the maximum size > 1.0 cm.Shear wave velocities (SWV) of nodules were measured by means of VTIQ technique.With pathological diagnosis as the gold standard,SWV value of benign and malignant nodules were analyzed and ROC curve was drawn to assess the diagnostic efficiency.Results By the ROC curve test,at SWV cut-off values of 2.44 m/s for group Ⅰ and group Ⅱ,2.49 m/s for group Ⅲ,the sensitivity were 79.0 %,76.0 %,88.6%,specificity were 88.6%,89.5 %,93.7 %,accuracy were 83.5 %,81.8 %,90.1%,Youden index were 0.68,0.66,0.82,respectively.Conclusions VTIQ can reflect the hardness of TI-RADS 4 nodules,the value of the differential diagnosis of such nodules is high,convenient,noninvasive and not limited by the size of nodules.
3.Dual screening for targeted gene replacement mutant in Magnaporthe oryzae with GUS as negative marker.
Jiaoyu WANG ; Zhen ZHANG ; Xinfa DU ; Rongyao CHAI ; Xueqin MAO ; Haiping QIU ; Yanli WANG ; Guochang SUN
Chinese Journal of Biotechnology 2009;25(1):129-138
To improve the efficiency of targeted gene replacement (TGR), a dual screen (DS) system with gusA gene as negative selective marker (GUS-DS) was developed in Magnaporthe oryzae. First, we tested the endogenous beta-glucuronidase (GUS) activities of 78 fungal strains. All tested strains were GUS-, only with 3 exceptions. Whereas, after the gusA being introduced in, M. oryzae, Fusarium oxysporum and Colletotrichum lagenarium acquired high GUS activities. The gusA is thus usable as a selective maker in fungal species. With gusA as the negative marker, HPH gene as the positive marker, and the peroxisomal targeting signal receptor genes MGPEX5 and MGPEX7 as 2 instances of target genes, we established the GUS-DS system. After transformation, we collected the transformants from hygromycin B screen media and then tested the GUS activities of them. The GUS- ones were selected as potential mutants and checked in succession by PCR and Southern blotting to identify the true mutants and calculate the efficiency of GUS-DS. As a result, GUS-DS improved the screen efficiency for delta mgpex5 from 65.8% to 90.6%, and for delta mgpex7 from 31.2% to 82.8%. In addition, we established a multiple PCR (M-PCR) method for mutant confirmation. By amplifying the different regions at the targeted locus, M-PCR differentiated the wild type, the ectopic transformants and the mutants effectively and rapidly, and had the same reliability as Southern blotting. In conclusion, GUS-DS and M-PCR are useful tools to improve the efficiency of TGR and would be helpful for fungal genomics.
Escherichia coli
;
enzymology
;
genetics
;
Gene Expression Regulation, Enzymologic
;
Genes, Fungal
;
Glucuronidase
;
genetics
;
Magnaporthe
;
genetics
;
Mutagenesis, Insertional
;
methods
;
Mutation
;
Recombination, Genetic
;
Transformation, Genetic
4.A study on the monitor of gastric residual volume by ultrasound and its prediction on feeding intolerance during enteral nutrition in critically ill patients in intensive care unit
Chuang CHEN ; Jiefeng XU ; Shaoyun LIU ; Yuzhi GAO ; Xinfa DING ; Mao ZHANG
Chinese Journal of Emergency Medicine 2020;29(10):1291-1295
Objective:To explore the feasibility of bedside ultrasound in monitoring gastric residual volume and predicting feeding intolerance during enteral nutrition in critically ill patients in intensive care unit.Methods:The data of critically ill patients admitted to emergency intensive care unit of the Second Affiliated Hospital of Zhejiang University School of Medicine from April 2018 to September 2018 were retrospectively analyzed. The following patients were finally included in this study: (1) abdominal computed tomography during the stay of emergency intensive care unit was performed due to the requirement of disease evaluation and management; (2) bedside ultrasound was performed to measure the gastric antrum cross-sectional area at 30 min prior to or after abdominal computed tomography. The outline of stomach wall in the imaging of abdominal computed tomography was traced with the help of VOLUME-Work Flow medical imaging software to calculate the value of gastric residual volume. The relationship between gastric antrum cross-sectional area under semi-sitting, horizontal and right-lateral positions and gastric residual volume was evaluated by Pearson correlation analysis. The difference of gastric antrum cross-sectional area between those critically ill patients with or without feeding intolerance was compared by independent-sample t test. The predictive value of gastric antrum cross-sectional area under different body positions on feeding intolerance during enteral nutrition was analyzed by ROC curve. Results:Totally, forty-two patients were enrolled and analyzed in this study, in which the mean age was (53±13) y, mean body mass index was (21.5±2.8) kg/m 2 and mean acute physiology and chronic health evaluation was 17.0±6.9. The value of gastric residual volume was (314.5±126.6) mL, and the values of gastric antrum cross-sectional area under semi-sitting, horizontal and right-lateral positions were (7.11±4.13) cm 2, (4.22±2.66) cm 2, (8.36±4.58) cm 2, respectively. The correlation analysis indicated that gastric residual volume was positively associated with gastric antrum cross-sectional area under semi-sitting, horizontal and right-lateral positions ( r=0.543, 0.604 and 0.618, respectively; all P<0.001). During enteral nutrition, 15 patients experienced feeding intolerance while 27 patients hadn’t feeding intolerance, in which the gastric antrum cross-sectional areas under semi-sitting, horizontal and right-lateral positions were significantly increased in those patients with feeding intolerance than those patients without feeding intolerance [semi-sitting: (8.53±4.07) cm 2vs (4.60±2.76) cm 2; horizontal position: (5.15±2.75) cm 2vs (2.61±1.32) cm 2; right-lateral position: (10.32±4.06) cm 2vs (4.95±3.20) cm 2, all P<0.005] . ROC curve analysis showed that the area under ROC curves of gastric antrum cross-sectional area under semi-sitting, horizontal and right-lateral positions for predicting feeding intolerance during enteral nutrition were 0.815, 0.833 and 0.849, respectively; when its values≥3.917 cm 2, 3.395 cm 2 and 4.402 cm 2 were used as the cut-off points, the sensitivities were 92.0%, 69.6% and 92.3%, and the corresponding specificities were 69.2%, 92.3% and 71.4%, respectively. Conclusions:Bedside gastric ultrasound could accurately evaluate the status of gastric residual volume in critically ill patients, and effectively predict their occurrence of feeding intolerance during enteral nutrition.
5.Diagnostic value of dual energy CT for lymph node metastasis in patients with non-small cell lung cancer.
Pingding KUANG ; Xinfa DING ; Jingjing XU ; Qijing ZHOU ; Minming ZHANG
Journal of Zhejiang University. Medical sciences 2017;46(5):511-516
OBJECTIVETo assess the diagnostic value of dual energy CT for lymph node metastasis in patients with non-small cell lung cancer (NSCLC).
METHODSForty NSCLC patients, including 15 cases of squamous cell carcinoma and 25 cases of adenocarcinoma, underwent dual energy CT examination in pre-contrast and venous phase contrast scans, then the CT attenuation value of the lung cancer lesions and 85 mediastinal enlarged lymph nodes (the short diameter ≥ 5 mm, 53 metastatic and 32 non-metastatic) were measured at different energy levels (40-190 keV, spacing 10 keV) in venous phase contrast. CT spectral curves of the lung cancer lesions, hilus pulmonis and mediastinal enlarged lymph nodes were produced automatically, through comparing their CT spectral curves slope to judge whether or not the lymph nodes were metastatic. Receiver operating characteristic (ROC) curve was used to evaluate the efficiency of CT spectral curve in diagnosis of lymph node metastasis.
RESULTSThe CT spectral curves slopes of the lung cancer, metastatic lymph nodes and non-metastatic lymph nodes were 1.10±0.11, 1.08±0.07 and 1.54±0.17, respectively. There was no significant difference in curve slope between metastatic lymph nodes and lung cancer (=-1.32,>0.05); while there was significant difference between non-metastatic lymph nodes and lung cancer (=-2.58,<0.05). The CT spectral curve slope ratios of metastatic and non-metastatic lymph nodes to lung cancer were 0.98±0.05 and 1.40±0.12, respectively (=-2.86,<0.05). ROC curve showed that taking CT spectral curve slope ratio of 1.15 as cut-off value for the diagnosis of metastatic lymph nodes, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 81.1%, 87.5%, 91.5%, 73.7% and 83.5%, respectively.
CONCLUSIONSDual energy CT is of value in improving the diagnostic accuracy of lymph node metastasis in NSCLC patients before treatment.