1.Influence of Invigorating Kidney and Activating Blood Formulae on Expression of IL-6 and MMP-13 in Synovial Fluid of Rabbits with Knee Osteoarthritis
Xianfeng PAN ; Xinbin YANG ; Peiqing DUAN ; Rong ZHANG ; Weiguo XIAO
Journal of China Medical University 2015;(10):909-912
Objective To investigate the expression levels of Interleukin(IL)?6 and matrix metalloproteinases(MMP)?13 in synovial fluid by in?vigorating kidney and activating blood formulae in treating rabbit knee osteoarthritis model. Methods A total of 30 New Zealand rabbit were ran?domly divided into blank group,model group,invigorating kidney group,activating blood group and invigorating kidney and activating blood group. Rabbits model with knee osteoarthritis were established by improved Hulth method. To give corresponding respectively the medicinal broth,model group was given saline,knee joint synovial fluid was collected after 4,8 and 12 weeks. Enzyme linked immunosorbent assay(ELISA)was used to measure the levels of IL?6 and MMP?13. Results The levels of IL?6 in rabbit knee osteoarthritis were obviously higher than that of normal control group at both 4 weeks and 8 weeks(P<0.001). But there was no statistical difference on the levels of IL?6 compared with controls in 12 weeks. In addition,the level of MMP?13 at 4 weeks,8 weeks and 12 weeks were significantly higher than the blank control group(P<0.001). After 8 weeks of Chinese medicine administration,the levels of IL?6 in synovial fluid were significantly decreased in invigorating kidney group,activating blood group and invigorating kidney and activating blood group(P<0.001),but there was no statistical difference among groups in 12 weeks. The MMP?13 levels of synovial fluid was significantly lower than the model group(P<0.001). Conclusion Our results indicate that IL?6 and MMP?13 par?ticipate in the pathological development of the rabbit knee osteoarthritis. Invigorating kidney and activating blood formulae could reduce the expres?sion of IL?6 and MMP?13 and alleviate osteoarthritis progression,and which is superior to the pure invigorating kidney formulae and activating blood formulae.
2.Comparison between the 7th edition of International Union Against Cancer staging system and the Chinese 2008 staging system for nasopharyngeal carcinoma and suggestions for the updating of the staging system
Zhongguo LIANG ; Hao LEI ; Zetan CHEN ; Ling LI ; Song QU ; Fang SU ; Wei ZHAO ; Su PEI ; Xinbin PAN ; Xiaodong ZHU
Chinese Journal of Radiation Oncology 2015;(6):653-658
Objective To compare the 7th edition of International Union Against Cancer ( UICC) staging system with the Chinese 2008 staging system for nasopharyngeal carcinoma ( NPC) , and to provide evidence for further updating of the staging system. Methods A retrospective analysis was performed among 767 patients who were pathologically and newly diagnosed with non?metastatic NPC and treated with intensity?modulated radiotherapy from 2006 to 2012. Based on the main prognostic indices, overall survival ( OS) , locoregional failure?free survival( LFFS) local relapse?free survival ( LRFS) , and distant metastasis?free survival ( DMFS) rates, the value of T stage, N stage, and clinical stage in prognostic prediction was compared between the two staging systems. The Kaplan?Meier method was used for calculating survival rates. The log?rank test was used for survival difference analysis. The Cox model was used for multivariate prognostic analysis. Results In terms of T stage, the Chinese 2008 staging system was a significantly better predictor of the OS and LRFS rates than the 7th edition of UICC staging system. In terms of N stage, they were comparable in the prediction of the OS and DMFS rates. In terms of clinical stage, the 7th edition of UICC staging system was a significantly better predictor of the OS rate than the Chinese 2008 staging system. For the new staging system proposed based on the statistical results, the T, N, and clinical staging gave significantly better prognostic prediction. Conclusions The 7th edition of UICC staging system and the Chinese 2008 staging system for NPC have their own advantages in prognostic prediction. The new staging system proposed in this study could contribute to the updating of the current staging system for NPC.
3.Finite element analysis of three-dimensional frame screws and minimally invasive plate for fixation of Sanders Ⅲ calcaneal fractures
Dewei KONG ; Chao SONG ; Liang WU ; Ming WU ; Lulu GONG ; Jiaqi WANG ; Hongyuan PAN ; Xinbin FAN ; Yan ZHANG
Chinese Journal of Tissue Engineering Research 2024;33(33):5289-5294
BACKGROUND:Satisfactory clinical results have been achieved in the treatment of Sanders Ⅲ calcaneal fractures by percutaneous compression fixation with three-dimensional frame screws.However,whether the stability of minimally invasive plate internal fixation can be achieved in terms of biomechanics,and the advantages and disadvantages after comparison are still unknown. OBJECTIVE:To investigate the fixation effect of different internal fixation devices on Sanders Ⅲ calcaneal fractures by finite element analysis. METHODS:A finite element model of Sanders Ⅲ calcaneal fracture was made based on CT data of a 26-year-old healthy male volunteer.The calcaneal fracture models were fixed by minimally invasive three-dimensional frame screws and minimally invasive Y-plate.The longitudinal loads of 350 and 700 N were applied respectively.The displacement and stress distribution of the two models were analyzed,and the stability of each model was compared. RESULTS AND CONCLUSION:(1)The peak stress of bone block and implant in the minimally invasive three-dimensional frame screw model was significantly lower than that in the minimally invasive minimally invasive plate model.The average stress of bone block and implant in the three-dimensional frame screw model was also significantly lower than that in the minimally invasive plate model.(2)The maximum displacement of the two models was located at the medial side of the articular surface of the posterior talus,and the maximum displacement of the three-dimensional frame screw model was smaller than that of the minimally invasive plate model.(3)The longitudinal displacement between the anterior fragment and the medial fragment of the minimally invasive plate model was smaller,and the transverse and vertical displacement between the medial fragment and the middle fragment of the three-dimensional group screw model was smaller.(4)It is concluded that both of the two internal fixation models can provide satisfactory fixation effect.The three-dimensional frame screw model can provide better transverse and vertical stability with more uniform stress distribution and smaller comprehensive displacement of bone fragments,while the minimally invasive plate has more advantages in maintaining longitudinal stability.
4.Finite Element Analysis of Three-Dimensional Screws and Circular Plates for Treating Sanders Type Ⅲ AB Calcaneal Fracture
Hongyuan PAN ; Dewei KONG ; Yue LIU ; Lulu GONG ; Yiding ZHAO ; Dece KONG ; Jiaqi WANG ; Zhi WANG ; Tieyi YANG ; Xinbin FAN
Journal of Medical Biomechanics 2024;39(3):435-441
Objective To investigate the effects of three-dimensional(3D)screws and circular plates on the biomechanical stability of Sanders ABⅢ calcaneal fractures.Methods Calcaneal computed tomography(CT)and magnetic resonance imaging(MRI)data from a 26-year-old volunteer were collected to establish a 3D finite element model of Sanders ⅢAB calcaneal fracture fixed with 3D screws and circular plates.A longitudinal load of 700 N was applied to compare the variations in the stress,displacement of the bone block,and internal fixation in the different models.Results Under 700 N longitudinal loads,the maximum displacement of the bone block and the maximum stress of the bone block and internal fixation were concentrated at the intersection of the posterior talar articular plane internal fixation and fracture line.The overall displacements of the bone blocks in the 3D screw and circular plate models were similar.Compared with the circular plate model,the maximum and average stresses of the bone block and internal fixation in the 3D screw model were lower,and the displacement and stress changes of the 3D screw model were closer to those of the complete calcaneal bone model.Conclusions In the fixation of Sanders ⅢAB calcaneal fractures,both 3D screw and circular plate fixation method can provide good stability.The biomechanical properties of the 3D screws were better than those of the circular plates,which is consistent with the biomechanical characteristics.