1.Study on the Optimum Order of Autoregressive Models for Heart Rate Variability Analysis.
Xiaoke CHAI ; Buqing WANG ; Zhengbo ZHANG ; Weidong WANG
Journal of Biomedical Engineering 2015;32(5):958-964
Heart rate variability (HRV) analysis technology based on an autoregressive (AR) model is widely used in the assessment of autonomic nervous system function. The order of AR models has important influence on the accuracy of HRV analysis. This article presents a method to determine the optimum order of AR models. After acquiring the ECG signal of 46 healthy adults in their natural breathing state and extracting the beat-to-beat intervals (RRI) in the ECG, we used two criteria, i. e. final prediction error (FPE) criterion to estimate the optimum model order for AR models, and prediction error whiteness test to decide the reliability of the model. We compared the frequency domain parameters including total power, power in high frequency (HF), power in low frequency (LF), LF power in normalized units and ratio of LF/HF of our HRV analysis to the results of Kubios-HRV. The results showed that the correlation coefficients of the five parameters between our methods and Kubios-HRV were greater than 0.95, and the Bland-Altman plot of the parameters was in the consistent band. The results indicate that the optimization algorithm of HRV analysis based on AR models proposed in this paper can obtain accurate results, and the results of this algorithm has good coherence with those of the Kubios-HRV software in HRV analysis.
Adult
;
Autonomic Nervous System
;
Electrocardiography
;
Heart Rate
;
Humans
;
Models, Cardiovascular
;
Reproducibility of Results
;
Software
2.The Study of the Measurement of Heart Rate Variability Using ECG and Photoplethysmographic Signal.
Buqing WANG ; Xiaoke CHAI ; Zhang ZHENGBO ; Weidong WANG
Chinese Journal of Medical Instrumentation 2015;39(4):249-264
In comparison with the measurement of heart rate variability from ECG and from photoplethysmographic signal from 46 healthy adults in their spontaneous breathing state. The beat-to-beat intervals in ECG and pulse-to-pulse intervals in photoplethysmographic signal are extracted, and then the parameters of heart rate variability are calculated. Three kinds of algorithms are chosen to get the pulse-to-pulse intervals, which are the intervals of maximum of second derivative, the maximum of PPG signal and the tangent intersection. The results show that the correlation coefficients of the HRV parameters in the two calculation methods are highly correlated. The Bland-Altman scattered plots show the relative bias results from the algorithm of the maximum of PPG signal are smallest and singular points that deviate from the consistent limits are the least compared with the other two algorithms.
Adult
;
Algorithms
;
Electrocardiography
;
Heart Rate
;
Humans
;
Photoplethysmography
;
Reproducibility of Results
3.Change of pulse transit time during stepwise paced breathing.
Xiaoke CHAI ; Buqing WANG ; Zhengbo ZHANG ; Guojing WANG ; Weidong WANG
Journal of Biomedical Engineering 2014;31(6):1325-1341
To investigate the effect of stepwise paced breathing (PB) on pulse transit time (PTT), we collected physiological signals of electrocardiogram (ECG), respiration and arterial pulse wave during a procedure of stepwise PB, which consists of 6 different breathing rates changing in a protocol of 14.0-12.5-11.0-9.5-8.0-7.0 breath per minute (BPM), with each breathing rate lasting 3 minutes. Twenty two healthy adults involved in this experiment and the change of PTT was analyzed during the stepwise PB procedure. In our study, the PTT was measured by calculating the time interval from the R-spike of the ECG to the peaks of the second derivative of the arterial pulse wave. Ensemble empirical mode decomposition (EEMD) was applied to PTT to decompose the signal into different intrinsic mode function, and respiratory oscillation and trend component (baseline) in PTT were further extracted. It was found that the respiratory oscillations in the PTT increased with decreasing of the PB rate, and many of the subjects (14 out of 22) showed the phenomena of PTT baseline increasing during the stepwise PB procedure. The results indicated that the stepwise PB procedure induced a high level of cardiovascular oscillation and produced an accumulative effect of PTT baseline increase. As PTT is capable of predicting changes in BP over a short period of time, increase of PTT baseline indicates the decrease of blood pressure. The experiments showed that the stepwise PB procedure could reduce blood pressure for most subjects. For future work, it is necessary to develop certain indices differentiating the effectiveness of the stepwise PB procedure on the PTT baseline change, and to test the effectiveness of this stepwise PB procedure on blood pressure reduction for patients with essential hypertension.
Adult
;
Blood Pressure
;
Blood Pressure Determination
;
Electrocardiography
;
Essential Hypertension
;
Humans
;
Hypertension
;
Pulse Wave Analysis
;
Respiration
;
Respiratory Rate
4.Clinical data mining by exploring public MIMIC-II intensive care database.
Jian WANG ; Zhengbo ZHANG ; Weidong WANG ; Liang PAN ; Xiaoke CHAI
Chinese Journal of Medical Instrumentation 2014;38(6):402-406
This paper introduces a free and publicly open ICU database: multi-parameter intelligent monitoring in intensive care II: MIMIC-II, which has been built up and maintained by the laboratory of computational physiology at the Massachusetts Institute Technology, Beth Israel Deaconess Medical Center and Philips Healthcare over the past decade. This paper briefly introduces its infrastructure, implementation and applications in clinical studies. Clinical study pertaining to circadian variation in heart rate and blood pressure during sepsis is shown as a typical example of research performed with MIMIC-II. In this study, it was found there was significant difference in circadian variation in both heart rate and blood pressure between survival and non-survival groups in septic patients. This study tackled several important techniques necessary for the investigation of the circadian rhythm.
Blood Pressure
;
Circadian Rhythm
;
Critical Care
;
Data Mining
;
Databases, Factual
;
Heart Rate
;
Humans
;
Medical Informatics
5.Application of Neural Prosthesis in Rehabilitation of Cervical Spinal Cord Injury (review)
Zilong DIAO ; Xinxin MA ; Xiaoke CHAI ; Ran BAI ; Weijun GONG
Chinese Journal of Rehabilitation Theory and Practice 2017;23(4):394-397
Neural prosthesis control system is based on brain-computer interface and functional electrical stimulation technology, by an-alyzing the electroencephalograph control commands directly into the muscle system or an external device, which compensated efferent pathway from the brain-spinal cord, and recovered motor function of patients with cervical spinal cord injury. This paper described the basic structure, working principle and key technology of neural prosthetic system, summarized the application, problems and prospects of neural prosthetic technology in the rehabilitation of cervical spinal cord injury.
6.Study of Steady State Motion Visual Evoked Potential-based Visual Stimulation of BCI System.
Guitong LIU ; Zhimin ZHANG ; Xiaoke CHAI ; Yangting LU ; Yubo FAN ; Haijun NIU
Chinese Journal of Medical Instrumentation 2018;42(5):313-316
OBJECTIVETo propose a square's ring motion stimulation based on steady-state motion visual evoked potential, and compare it with the commonly used visual stimulation modes (Newton's ring motion, square flicker and circular flicker).
METHODSEEG signals were collected while 9 experimental subjects gazing at four stimulation and pattern analyzed by Canonical Correlation Analysis (CCA). Stimulation were evaluated by recognition accuracy and subjective scores.
RESULTSThe classification accuracies of SSVEP elicited by the square's ring motion(82.8%±14.1%) and Newton's ring(83.3%±11.5%) have no significant difference between them, which are lower than that of the square flicker(98.3%±4.1%) and the circular flicker(99.2%±1.8%). The shape of the figure has no significant influence on the classification accuracy either in motion mode or flicker mode. The comfort of the square's ring motion is higher than the other three stimulation according to subjective scores.
CONCLUSIONSThe square's ring motion can elicit EEG and reduce the discomfort caused by flicker modes. The square's ring motion can be used as a visual stimulation in SSMVEP-based BCI system.