1.CEUS features of hepatitis B virus-related combined hepatocellular-cholangiocarcinoma and hepatocellular carcinoma: Comparative study
Guangliang HUANG ; Jieyi YE ; Xiaoer ZHANG ; Wei WANG ; Xiaowen HUANG ; Mingde LYU ; Xiaoyan XIE
Chinese Journal of Interventional Imaging and Therapy 2017;14(8):494-498
Objective To comparatively analyze CEUS features of hepatitis B virus (HBV)-related combined hepatocellular-cholangiocarcinoma (CHC) and hepatocellular carcinoma (HCC).Methods Thirty-one patients with HBV-related CHC and 31 patients with HBV-related HCC confirmed by pathology were enrolled and CEUS features were compared.Results On CEUS,HBV-related CHC and HBV-related HCC mainly manifested as hyper-enhanced in arterial phase and hypo-enhanced in portal phase and delayed phase.No significant differences of enhancement level on CEUS were found between HBV-related CHC and HBV-related HCC.When the maximum diameter of tumor ≤3.0 cm,both HBV-related CHC and HBV-related HCC were mainly homogeneous enhancement (P=1.000).When the maximum diameter of tumor more than 3.0 cm,diffuse heterogeneous enhancement and peripheral irregular rim-like enhancement were more commonly observed in HBV-related CHC,while diffuse heterogeneous enhancement was more commonly noted in HBV-related HCC (P=0.001).Conclusion The enhancement pattern of HBV-related CHC >3.0 cm has relative specific performance.
2.Ultrasound-guided percutaneous ablation treatment for current hepatoblastoma: initial single-center experience
Pengliang LI ; Jia LUO ; Xiaoer ZHANG ; Baoxian LIU ; Luyao ZHOU ; Guangliang HUANG ; Quanyuan SHAN ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):813-816
Objective To summarize the first experience with ultrasound-guided percutaneous ab lation treatment (PAT) for recurrent hepatoblastoma (HB) after liver resection in children.Methods From August 2013 to April 2015,PAT was used to treat 6 children with a total of 9 recurrent HB,including 5 patients with 8 tumors in the liver and 1 patient with 1 tumor in the lung.The mean size of ablated tumors was (1.5 ± 0.8) cm,and the tumor size range was 0.7 cm to 3.1 cm.Results Four patients were performed percutaneous radiofrequency ablation (RFA) for recurrent HB;and 2 patients were performed percutaneous ethanol injection (PEI).Ablation success was achieved in all patients (6/6,100%).The complete ablation rate after the first ablation session was 88.9% (8/9) on a tumor-by-tumor basis.Only 1 patient developed a fever with temperature > 39 ℃;it was resolved by conservative therapy.During the follow-up period of 5-30 months,3 patients died to tumor progression.The 1-and 2-year overall survival rates after ablation were 83.3% and 41.7%,respectively.Conclusions PAT is a safe and promising therapy for children with recurrent HB after liver resection,and further investigation in large-scale randomized clinical trials is required to determine its role in the treatment of this disease.
3.Multiple-electrode radiofrequency ablation via switching system in treating early-stage hepatocellular carcinoma
Guangliang HUANG ; Jia LUO ; Xi DING ; Xiaoer ZHANG ; Baoxian LIU ; Manxia LIN ; Ming KUANG ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):810-812,816
Objective To retrospectively compare the safety and local efficacy of multiple-electrode switching based radiofrequency ablation (RFA) and the conventional RFA in treating single early-stage hepatocellular carcinoma (HCC).Methods A total of 82 patients with single early-stage HCC received either RFA with a multiple-electrode switching system (n =43) or conventional RFA (n =39) as the first-line treatment.The rate of initial local complete response,major complications and local tumor progression (LTP) were compared between two groups.Results The total ablation time was significantly shorter in the switching-RFA group [(16.7 ± 3.4) mins] than in the conventional RFA group [(29.8 ± 10.4) mins] (P < 0.05).The rate of initial local complete response was 100% (43/43) in the switching-RFA group and 94.9% (37/39) in the conventional RFA group (P >0.05).After a mean follow-up period of (26.4 ± 21.8)months (ranging 3.0-91.6 months),the rates of LTP in the switching-RFA group and conventional RFA group were 16.3% (7/43) and 17.9% (7/39),respectively.The LTP rates in two groups were 16.1% versus 11.2% atyear1,and20.5% versus 20.6% at year2 (P=0.666).Conclusions The multiple-electrode switching based RFA is safe and effective with shorter ablation time in treating single early-stage hepatocellular carcinoma.
4.Analysis of complication associated with Ultrasound-guided percutaneous RFA for hepatic cellular carcinoma
Xiaoer ZHANG ; Guangliang HUANG ; Xiaoyan XIE ; Ming XU ; Baoxian LIU ; Jieyi YE ; Mingde LYU ; Manxia LIN
Journal of Chinese Physician 2017;19(6):804-806
Objective To evaluate the safety and effective of ultrasound-guide percutaneous radio frequency ablation (RFA).Methods Retrospectively analyze the incident,management and influence factors of complication of ultrasound-guide percutaneous RFA.Results From 2001 to 2011,536 patients with 762 lesions underwent RFA were enrolled in this study.Incident of RFA complication was 2.03% (11/536),including 5 (0.92%) major complication.The complication covered fever (1 case),massive hydrothorax (2 cases),hydrothorax accompany with ascites (1 case),massive ascites (1 case),liver abscess (1 case),liver capsule hemorrhage (1 case) and hemothrorax (1 case).No RFA relate mortality was observed.According to logistics regression analysis,the liver function Child-Pugh grading was associated with the RFA complication (P =0.005).Conclusions Ultrasound-guide percutaneous RFA is a safe and effective local treatment approach for hepatocellular carcinoma.It's necessary to comprehensively think over the basic condition of patients and the characters of tumor such as tumor location,size and abutting organs.Nevertheless,an appropriate treatment plan and closely monitor during and after RFA are crucial.
5.A clinical study of virtual endoscopy ultrasound Fly-Thru in the diagnosis of obstructive degree and nature for obstructive bile duct diseases
Xiaoer ZHANG ; Wei WANG ; Xiaoyan XIE ; Guangliang HUANG ; Tongyi HUANG ; Jieyi YE ; Mingde LYU ; Ming XU
Chinese Journal of Ultrasonography 2017;26(7):603-607
Objective To investigate the utility of virtual endoscopy ultrasound Fly-Thru in the diagnosis of obstructive bile duct diseases.Methods One-hundred patients with obstructed bile duct diseases underwent Fly-Thru examination.All Fly-Thru images were reviewed by two radiologists with different experience.The capabilities of Fly-Thru for bile duct obstructive degree evaluation and distinguishing malignant lesion from benign one were assessed respectively.Results The accuracy and sensitivity of Fly-Thru image in obstruction degree evaluation were 70.59% and 89.2% (95%CI 74.6%-96.9%).The diagnosis accuracy of 2DUS for lesion characteristics increased from 80% to 84%,accompany with Fly-Thru images,especially for lesions in common bile duct from 77.2% to 86.0% (x2 =14.399,P =0.001).Conclusions The virtual endoscopy ultrasound Fly-Thru is only partly capable to display the obstructed degree of some bile ducts,but it can improve the diagnostic accuracy of common bile duct diseases.
6.Early assessment of the therapeutic response to radiofrequency ablation for hepatic local lesion with 3-dimensional contrast-enhanced ultrasound registration system a preliminary study
Xiaoer ZHANG ; Ming XU ; Xiaoyan XIE ; Longfei CONG ; Teng SUN ; Jieyi YE ; Mingde LYU ; Guangliang HUANG
Chinese Journal of Ultrasonography 2016;25(6):502-505
Objective To investigate the feasibility of our new found 3-dimensional contrast-enhanced ultrasound 3D-CEUS registration system as an early assessment of the therapeutic response to radio frequency ablation for liver cancer Methods Twenty-seven patients with 28 lesions accepted 3D-CEUS before and after radio frequency ablation RFA the therapeutic respond to which would be assessed with 3D-CEUS registration system recording the rate of successful registration The CT was considered as the reference standard Results Ten cases 35 7% were successful matched with auto-registration and 24 cases 85 7% were succesful matched with interactive-registration relatively All cases were considered as complete ablated which were confirmed by CECT with 100% accuracy There were two cases achieving ablation margins ≥5 mm without local tumor progression LTP and nineteen cases achieving 0 -4 mm ablation margin with 3 LTP 3-month 6-month and 1-year later Conclusions The 3D-CEUS interactive-registration system can easily assess the therapeutic response of RFA in liver cancer immediately with high accuracy.
7.Study of the influent factors and reconstructing condition for the virtual endoscopy technique Fly-Thru (FT) in bile duct model in vitro
Xiaoer ZHANG ; Ming XU ; Wei WANG ; Guangliang HUANG ; Luyao ZHOU ; Xiaoyan XIE
Chinese Journal of Ultrasonography 2015;24(10):902-906
Objective To investigate the factors affecting Fly-Thru (FT) and the best reconstruction conditions in a bile duct model.Methods The bile duct model was made with corn powder and rubber pipes.FT data of bile duct in vitro were acquired with a 3-dimensional probe of Toshiba Aplio 500,and the data were reconstructed offline in Fly-Thru workstation.Two US doctors assessed the FT images in three degrees.Results The images were divided into good,moderate and poor groups with corresponding score 3,2,1.Of 162 images,72 were rated as grade 1,57 as grade 2 and 33 as grade 3.According to x2 analysis,the diameter,scanning way,and Filter were brought into multinomial regression,then the scanning way was found to be correlated to FT images quality as well as filter (likelihood ratio =87.598,294.290,x2 =9.492,313.722,respectively,P <0.01).Best images of FT can be acquired by transverse scanning,reconstructing in Filter =3,gain =5(0,dynamic range (DR) =50 and threshold ranging 40-90.Conclusions Best FT images in the model could be achieved by scanning in short-axis,and reconstructing the data in Filter =3,gain =50,DR =5(0 and threshold ranging 40-90,which would be basic information for advanced clinic study.
8.The value of MRI in monitoring incomplete healing of the uterine incision after abdominal delivery
Xing ZHONG ; Ji ZHANG ; Ping CUI ; Xiaoer ZHAO ; Hui WU ; Hu LIAN
Journal of Practical Radiology 2016;32(12):1906-1908
Objective To explore MRI manifestations of incomplete healing of the uterine incision after abdominal delivery.Methods Nine patients with clinical suspected incomplete healing of the uterine incision after abdominal delivery underwent cavitas pelvis MRI scans with 3.0T MRI.Results According to the characteristics of the MRI images,healing conditions of the uterine incisions were divides into 2 groups.GroupⅠwas showed that the uterine incision healed well,the uterine junctional zone and myometrium were continuous,and the incision scar was linear low signal intensity on T2 WI (2 cases,22%).GroupⅡwas showed that the uterine incisions healed incompletely,the uterine junctional zone and myometrium were discontinuous,and the myometrium edema was in some cases with high signal intensity on T2 WI (7 cases,78%).Conclusion MRI could directly displays incomplete healing of the uterine incision after cesarean section,provide the basis for clinical diagnosis and treatment.
9.CK assay with gene testing for screening of Duchenne muscular dystrophy in the newborn infants
Xiaoer YANG ; Jing YU ; Heyu HU ; Li ZHANG ; Li SUN ; Bo GONG
Chinese Journal of Laboratory Medicine 2015;38(1):32-34
Objective To establish a system using CK activity assessing with follow-up Duchenne muscular dystrophy (DMD) gene testing to newborn screening for DMD.This study provided a pathway to improve the health outcome for individuals with DMD.Methods Tests for CK were performed with Beckman original reagent on a Beckman Coulter AU 5800.Preliminary studies established a population-based range of CK in newborns using 5 892 deidentified anonymous blood samples,which were collected from Shanghai Changning Maternity and Infant Health Hospital between November 2013 and July 2014.Mutation analysis used multiplex PCR-denature high-performance liquid chromatography (PCR-DHPLC) method for screening large duplications and deletions and Sanger DNA sequencing for screening point DMD gene mutation.Results DMD gene mutations (point mutation,exon60,c.9072G > A) were found in 1 of 5 892 newborn subjects,which had CK level > 2 000 U/L large duplications and deletions in DMD gene were not found.Conclusions A system of analysis for newborn screening for DMD has been established.This path for newborn screening fits our health care system and minimizes the false-positive results for predicting DMD gene mutations by use of CK levels in blood
10.Different heating modes of Cool-tip on coagulation zone and thremal distribution in vitro and in vivo experiment
Xiaoju LI ; Manxia LIN ; Xiaoyan XIE ; Ming XU ; Bowen ZHUANG ; Ming LIU ; Mingde LYU ; Bei HUANG ; Baoxian LIU ; Xiaoer ZHANG ; Yin LU
Chinese Journal of Ultrasonography 2016;25(6):530-535
Objective To compare the features of different heating modes cauterization mode and standard ablation mode of Cool-tip on coagulation zone and thermal field distribution in order to provide references for focused and accurate vascular occlusion and explore the primary efficacy of Cool-tip applied to intrahepatic vascular occlusion in living dogs Methods Ex-vivo porcine livers were ablated for 2 4 6 8 minites with cauterization mode and standard ablation mode respectively and the long- and short-axis diameters in the greatest dimension were compared The tissue temperature around the tip midpoint and end of the exposed part of radiofrequency electrode were measured under the circumstance of 4 min ablation by the two modes respectively Animal experiment the intrahepatic vessels of 2 Beagles were ablated with cauterization mode one procedure for each animal and contrast-enhanced ultrasound was used to evaluate the perfusion change of liver tissue Gross anatomy and pathological examination of the liver was performed after 1 week Results In the 2 min 4 min 6 min and 8 min ablation the coagulation volume of cauterization mode and standard ablation mode were 1 01 ± 0 41 cm 3 vs 2 95 ± 0 74 cm 3 1 47 ± 0 33 cm 3 vs 5 03±1 06 cm 3 2 29±0 49 cm 3 vs 9 23±2 53 cm 3 2 70±0 24 cm 3 vs 1 5 89±0 77 cm 3 The coagulation volume was significant smaller in cauterization mode than in standard ablation mode P <0 05 for all The peak temperature of cauterization mode presented on the tip of electrode which averaged 94 4℃ in maximum and maintain around 70 ℃ in the equilibrium phase The peak temperature of standard mode presented on the midpoint of the electrode which periodically variated between 70 ℃- 100 ℃ The result of the animal experiment showed that cauterization mode could be used to occlude the intrahepatic vessel in vivo which induced the ischemia and necrosis in the corresponding area Conclusions Cauterization mode and standard alation mode of Cool-tip have different characteristic in terms of coagulation zone and thermal distribution and carterization mode may have a promising application in intrahepatic vascular occlusion.