1.Effect of anti-sense osteopontin on metastasis and infiltration of esophagus cancer
Peiran XU ; Zhiguang YANG ; Xianzhang YAO ; Guoguang SHAO
Journal of Jilin University(Medicine Edition) 2006;0(02):-
Objective To investigate the effect of anti-sense osteopontin(ANOPN)on proliferation and metastasis of esophagus cancer cells.Methods An OPN gene recombinant expression vector plasmid was constructed by RT-PCR from human umbilical vein endothelial cell gene and cloned into a mammalian expression vector pcDNA3.1(+).PcDNA3.1-ANOPN was introduced by LipofectinTM.Positive cell clones(ECA-ANOPN),vector-transfected cells ECA-vect and blank cell ECA were used as three groups.RT-PCR and immunocytochemistry assay were used to investigate the expressions of OPN mRNA and protein.The metastasis characteristics of cells were studied by Transwell method.Results The vector was constructed successfully,the sequencing result was identical with that reported in GenBank.Compared with vector-transfected cells(ECA-vect cells) and ECA cells,the growth rate of ECA-ANOPN cells was significantly slowed(P
2.Ultrasound ablation and balloon angioplasty in treating peripheral arterial occlusion in diabetes mellitus
Dongmei JING ; Xianzhang XU ; Ailin WANG ; Meng ZHANG
Chinese Journal of Endocrinology and Metabolism 2009;25(1):56-57
Objective To evaluate the efficacy of ultrasound ablation and balloon angioplasty in treating peripheral arterial occlusion in diabetes mellims. Methods One hundred and fifty-eight patients with peripheral arterial occlusion were treated with the ultrasound ablation. Through percutaneous approach or surgical approach, the ultrasound ablation catheter was inserted into occluded arterial segments. Results The ultrasound ablation was successful in 149 of 158 patients (94%). After treatment, the average skin temperature rised for 3℃ and the distance of intermittent claudicafion was increased for 1 000 m. The gangrene was mitigated in 38 of 45 patients. The pain during rest was ameliorated in 31 of 35 patients. Long-term efficacy was 75%. Conclusion Ultrasound ablation is effective and is a new approach for treating peripheral arterial occlusion in diabetes mellitus.
3.Influence of some herbal medicines and foods on the INR of patients under warfarin therapy
Xianzhang HUANG ; Zhenjie LIU ; Wujiao HUANG ; Ning XU ; Junhua ZHUANG
Chinese Journal of Laboratory Medicine 2014;(9):715-718
Warfarin is a well-accepted drug used for preventing thromboembolic diseases. It is important to monitor the dosage of warfarin. Prothrombin time is one of the screening tests of extrinsic coagulation path,which is the first choice to monitor the oral use of warfarin. Standardized prothrombin time, namely international normalized ratio ( INR ) is used to adjust warfarin dosage in clinical practice. Many herbal medicines and foods may enhance the effect of warfarin therapy,and some of them may weaken this effect,which can result in severe clinical complications.
4.HR-ICP-MS method for the determination of ultratrace uranium in multi-stage atmospheric particles
Ying XU ; Liangliang YIN ; Fei CHEN ; Xianzhang SHAO ; Xiangyin KONG ; Yanqin JI
Chinese Journal of Radiological Medicine and Protection 2017;37(3):212-215
Objective To establish an effective and reliable method for analysis of uhratrace uranium in multi-stage atmospheric particles providing the monitoring and evaluation of the content of radioactive uranium in the atmosphere.Methods A large volume six-stage-impactor sampler of atmosphere particles was used to collect aerosol samples,and uhratrace uranium in particles was digested using microwave and measured by inductively coupled plasma mass spectrometry.The filter material,digestion conditions and microwave digestion system had been optimized.Results The background of uranium level on the cellulose filter was the lowest,and the samples were digested by using HNO3-HCI (aqua regia)-H2O2 solution.Reference material SRM2783 was used to validate the accuracy of the method,and the relative error of the 238U was 7%,The detection limit of the method was 2 × 10-4ng/m3.The aerosol actual samples were analyzed using the established method.The mass concentrations of uranium in PM2.5 was in the range of 0.023-0.065 ng/m3.Conclusions The established method was effective and reliable to monitor the concentration level of ultratrace uranium in multi-stage atmospheric particles.
5.Determination of uranium in drinking water in the vicinity of nuclear power plants by ICP-MS
Qing TIAN ; Yanqin JI ; Liangliang YIN ; Wei HUANG ; Xianzhang SHAO ; Baoming SHEN ; Xu SU
Chinese Journal of Radiological Medicine and Protection 2011;31(2):160-162
Objective To ascertain the concentrations of uranium in drinking water around nuclear power plants.Methods A total of 106 water samples were collected from June 2009 to March 2010 in Jiangsu,Zhejiang,Liaoning and Shandong provinces.Inductively coupled plasma-msgs spectrometry(ICPMS)was applied to determine uranium content in local water source and drinking water.The detection limit of U was 0.8 ng/L.The recovery was 100.9%.Results The uranium concentrations in all samples were less than 15μg/L which was the limit given by World Health Organization(WHO).Conclusions The concentration of uranium in water sources was as follows:Liaoning>Shandong>Jiangsu>Zhejiang.The concentration of uranium in drinking water W88 maximal in Shandong Province and minimal in Zhejiang Province.
6.Evaluation of serum adenosine deaminase assays of different manufacturers and harmonization of test results
Songbai ZHENG ; Liping HE ; Liqiao HAN ; Jianbing WANG ; Haibiao LIN ; Junhua ZHUANG ; Jianhua XU ; Xianzhang HUANG
Chinese Journal of Laboratory Medicine 2014;(6):439-443
Objective To Evaluate the performance of serum adenosine deaminase assays of different manufacturers and explore the approach for harmonization of test results.Methods It was evaluated the indice including the limit of blank ,precision,linearity range and reference interval of 10 test systems.It was as the reference system by Mindray test system to evaluate the comparability and the difference of ADA results among 10 different systems.The evaluation was performed before and after calibration by a selected fresh serum assigned by the reference system.A commercial calibrator of the minimum matrix effect was selected from 8 different calibrators as the long-term calibrator to harmonize the ADA results of 10 systems.Results The results of LoB were 0.1-6.3 U/L,respectively.The within-run CVs and total CVs of 10 systems were all less than 5%and actual linearity ranges were conformed to claims of manufacturers.After calibration with fresh serum calibrator ,the averaged difference of 10 test systems was reduced from 14% to 3.0%, and the average difference was 1.8% after calibration with long-term calibrator.The common reference interval of all test systems was 5-24 U/L identically.Conclusions The comparability of ADA measurements can be improved by using a common human serum calibrator and the commutable commercial calibrator.And it is necessary and feasible to develop the standardzation of ADA.
7.90Sr in Chinese tea of typical regions: activity concentration and hygienic evaluation
Fei CHEN ; Liangliang YIN ; Xiangyin KONG ; Ying XU ; Yao ZHANG ; Xianzhang SHAO ; Yanqin JI
Chinese Journal of Radiological Medicine and Protection 2017;37(5):367-371
Objective To investigate the activity concentration of 90St in tea produced in Chinese typical regions,enrich the baseline data for 90Sr level in Chinese tea,and evaluate possible exposure doses to people.Methods Samples were carbonized,ashed,digested and leached,and then extraction chromatography method was used to separate 90Sr and 90y.After preparation of sample source,radioactivity of 90Y was measured using low-level α/β counter.Results Twenty six kinds of tea produced in 16 typical regions from 26 cities of 16 provinces were collected in 2016,and their 90Sr activity concentrations were analyzed using the separation method of di (2-ethylhexyl) phosphate (HDEHP) extraction chromatography.The results revealed that the activity concentrations in 26 kinds of tea samples ranged from 0.28 to 3.78 Bq/kg,and contributed possible exposure doses of 0.44 × 10-2-6.00 × 10-2 μSv to each people.Conclusions These doses were far less than the ICRP annual dose limit of 1 mSv for the public,suggesting less impact on people's health.
8.Evaluation of serum gamma-glutamyltransferase assays by using the International Federation of Clinical Chemistry and Laboratory Medicine reference method
Ning XU ; Songbai ZHENG ; Li LIN ; Junhua ZHUANG ; Jianhua XU ; Lianying LIN ; Lei SUN ; Longhua GUO ; Xianzhang HUANG
Chinese Journal of Laboratory Medicine 2009;32(5):494-498
Objective To evaluate the measurement accuracy of serum gamma-glutamyltransferase (GGT) assays manufactured in China. Methods The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference method for GGT was set up and, after verification, was used to evaluate the performance of routine assay systems made in China. The evaluation was performed twice before and after a calibration by a common serum calibrator. Results For the reference measurement, the within run and total CVs were all less than 1%. The biases with the target values of IFCC External Quality Assessment Scheme for Reference Laboratories (RELA) were all within the limit of equivalence. Before a calibration with a common calibrator, the largest biases of results of GGT of the routine tasting systems compared with reference method at three medical decide levels were -47.53%, -34.11% and -30.07% respectively, and the averaged biases were 14.53% ,12.88% and 12.48%. After calibrating by fresh serum calibrator,the largest biases were reduced to - 17.63%, -5.88% and -4.08% ,the averaged biases were reduced to 7.50%, 2.70% and 1.87%. Conclusion The performance of GGT measurements can be effectively improved by using a common fresh serum calibrator that has a value assigned with the reference method.
9.Discussion of the application of enzymatic reference methods in external quality assessment
Yun LI ; Xianzhang HUANG ; Songbai ZHENG ; Liqiao HAN ; Yongjian CAO ; Jianhua XU ; Li LIN ; Youqiang LI ; Junhua ZHUANG ; Jianbing WANG
Chongqing Medicine 2014;(6):692-695
Objective To discuss the feasibility of enzymatic reference methods in Routine Chemistry external quality assessment (EQA)inlaboratorymedicine.Methods Samplesofthe1stEQAin2012byNationalCenterforClinicalLaboratories(NCCL)and patients′sera were measured by reference methods and 5 clinical analytic systems for the catalytic activity of CK ,LDH ,ALP ,ALT , AST ,GGT and AMY ,then the results of 5 clinical systems were compared with the reference methods′or target value of NCCL by calculating the bias ,and evaluated them according to the criteria of EQA by NCCL .Results The results of EQA samples measured by reference methods was within ± 10% compared with NCCL target value .Compared with the results of reference method ,the through put was 100 .0% for wet clinical chemistry systems measuring both EQA samples and patients′serum ,and the dry clinical chemistry systems was 77 .1 for EQA samples and 97 .1% for patients′serum according to the criterion of EQA ,and the through put was 72 .9% and 63 .6% of wet clinical chemistry systems according to the standard of enzymatic trueness of NCCL .Conclusion Reference method could be applied to EQA ,and will be a great help for the trueness of clinical testing .
10.Comparison of measurements for ALT and AST among four domestic reference laboratories
Changyu XIA ; Yan LIU ; Hongyan GUO ; Guizhen SUN ; Xianzhang HUANG ; Junhua ZHUANG ; Qin YU ; Mulong LIU ; Lanzhen WANG ; Xuelian ZHANG ; Guobin XU
Chinese Journal of Laboratory Medicine 2009;32(5):499-503
Objective To investigate the intralaboratury and interlabomtory variations of measurements for ALT and AST among four domestic reference laboratories. Methods The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedures and IFCC procedures without pyridoxal 5-phosphate (PLP) were performed in the reference laboratories. Intralaboratory and interlaboratory CVs were compared with those in 2006 and 2007 IFCC External Quality Assessment Scheme for Reference Laboratories (RELA). Meanwhile, deviations of results for ALT, AST and AST/ALT between two methods were calculated. Results Interlaboratory CVs were generally higher than intralaboratory CVs. Interlaboratory CVs among the 41 laboratories were lower than these in RELA. Results of ALT and AST using method with PLP were higher than those using method without PLP. Difference of AST/ALT ratio between the two methods was significant. Conclusions For reference measurement of the 2 enzymes, interlaboratory CVs of < 3.5 are achievable on frozen serum materials. Measurements on lyophilized materials may have higher CVs. Further studies are needed for the investigation of the differences between results obtained in the absence and presence of PLP.