1.Neurotoxic effects of intrathecal different concentrations of ethanesulfonic acid ropivacaine on spinal cord in rats
Fangjun WANG ; Yang LIU ; Faping TU ; Yongmie WU ; Xianyong XIE ; Hongxie HE ; Huafen ZI
Chinese Journal of Anesthesiology 2010;30(5):533-535
Objective To evaluate the neurotoxic effects of intrathecal (IT) different concentrations of ethanesulfonic acid ropivacaine on spinal cord in rats. Methods Sixty healthy Wistar rats of both sexes weighing 210-220 g in which IT catheters were successfully placed according to Yaksh et al. were randomly divided into 5 groups (n= 12 each). The animals received 0.9% NaCl solution 0.4 ml (group C); 0.224%, 0.447%,0.671%, 0.894% ethanesulfonic acid ropivacaine 0.4 ml (group R1-4 ). The onset time and duration of the block were recorded. The animals were killed on 7th day after IT administration. The L4,5 segment of the spinal cord were removed for neuropathologic examination with electron microscope. The spinal cord injury was scored.Neurotoxicity was defined as the spinal cord injury score ≥ 2 and the spinal neurotoxicity was recorded. Results Onset time was shorter and duration of the block was prolonged with increasing concentrations of ethanesulfonic acid ropivacaine. The incidence of the spinal neurotoxicity was 0, 0, 17%, 42% and 100% in group C, R1, R2, R3 and R4 respectively. The incidence of the spinal neurotoxicity was gradually increased with increasing concentrations of ethanesulfonic acid ropivacaine. Conclusion IT ethanesulfonic acid ropivacaine can produce neurotoxicity to the spinal cord and it depends on the concentration.
2.Evaluation of an automated morphological analysis system in white blood cell identificaton
Geng WANG ; Hongjie XIE ; Xianyong JIANG ; Xin WANG ; Qian CHEN ; Wei WU ; Chunmei HUANG ; Yuan HUANG ; Wei CUI
Chinese Journal of Laboratory Medicine 2015;(3):168-172
Objective To evaluate the clinical performance of an automated image analysis systems named CellaVision DM96 in classifying White Blood Cells.Methods A total of 2267 peripheral blood samples (male 1 235, female 1 034, average age 46) were obtained from outpatient and inpatient in Peking Union Medical College Hospital ( PUMCH ) . These samples were selected to evaluate the precision, sensitivity, specificity and the analytical error of the system.We first evaluated the coincidence rate of reclassification and manual microscopy.On the base of favourable coincidence rate, we then evaluated the correlations between the pre-classification and reclassification of segmented neutrophil, band neutrophil, lymphocyte, monocyte, eosinophile, basophile, blast cell, promyelocyte, myelocyte, metamyelocyte, plasma cell and reactive lymphocyte.Results The sensitivity and specificity of pre-classification of White Blood Cell were 46% -100% and 24%-92%, respectively.When studied on the cell level, the total coincidence rate of pre-classification was 88%.And the coincidence rates of pre-classification and reclassification of White Blood Cell were 6%-95% and 25%-100%, respectively.When assessed on the sample level, the coincidence rates of pre-classification and reclassification of leukocytes were 64%-98%and 84%-100%, respectively.The correlations of pre-classification and reclassification of leukocytes in order from high to low were: lymphocyte, segmented neutrophil, eosinophile, band neutrophil, monocyte, basophile, when r were 0.943 9, 0.915 2, 0.785 4, 0.775 6, 0.676 2 and 0.289 1, respectively.The correlations between reclassification and manual microscopy of White Blood Cell were higher than those between pre-classification and manual microscopy.Order from high to low was: eosinophile, segmented neutrophil, lymphocyte, monocyte, band neutrophil, basophile.And r were 0.972 1, 0.968 5, 0.957 0, 0.831 9, 0.800 6 and 0.648 7, respectively.The ability of this automated image analysis systems at pre-classification in distinguishing between band cell and segment cell, atypical lymphocyte and normal lymphocyte was not good. Conclusion The performance of reclassification was better than pre-classification.The reclassification can be substitute for the microscopy inspection, and be used in the Clinical practice.