1.In vitro Selection of DNA Aptamer to Cyclosporin A by SELEX Method
Weibin LI ; Xiaopeng LAN ; Xiangyue YANG ; Changshao ZHOU
Chinese Journal of Biochemistry and Molecular Biology 2007;23(10):829-834
To obtain the aptamers with high affinity and specificity for cyclosporin A(CsA),a synthesized 78 nt single stranded DNA(ssDNA)random library containing 35 random sequences flanked by invariant primer was subjected to 1 1 rounds of selection against CsA by SELEX protocol.Magnetic beads were used for target immobilization and the biotin-streptavidin-horseradish peroxidase system was employed for determining the binding affinity between the aptamers and CsA. After ten rounds of selection and amplification, with an increasing affinity for each round,the selected aptamers were cloned,sequenced and analyzed for their primaryand secondary structures.The 19 aptamers were divided into five groups based on primary sequence homology.Hairpin loop is the main motif in the predicted secondary structure and is supposed to be the binding part of the aptamers to CsA.The CsA-specific aptamers will be useful for enzyme-linked assays or immunofluorescence asses of CsA.
2.Performance comparison among glucose detection reagents with different chromogens
Xiangyue YANG ; Xiaopeng LAN ; Lun ZHOU ; Lijun XU ; Anji SUN
International Journal of Laboratory Medicine 2015;(1):15-16
Objective To preliminarily evaluate the performance of glucose detention reagents with three kinds of different chro-mogens and to investigate their anti-interference performance according to NCCLS document.Methods According to the protocol EP10-A2 provided by the National Committee for Clinical Laboratory Standards(NCCLS),the samples with low,middle and high level of glucose were detected by the glucose reagent kits with 3 kinds of different chromogens.The bias,total imprecision,inter-cepts,slope rates,nonlinearities,carryover rate and drifts were calculated.The interference evaluation test was performed according to the document EP7-A2.Results The bias and total imprecision of three kinds of reagent kits were all within allowed ranges.No statistically significant differences were showed in intercepts,slope rates,nonlinearities,carryover rate and drifts.1450 turbidity chyle,5 g/L hematoglobin and 0.03 g/L vitamin C did not interfere with the assay of three kinds of glucose reagent kits with differ-ent chromogens.342 μmol/L free bilirubin,342 μmol/L conjugated bilirubin did not interfere with the detection of reagent with MAOS.Conclusion The glucose detention reagents with three different chromogens have good accuracy and precision,and various performance indexes all conform to the clinical application requirements,reagent with chromogen MAOS is better than other chro-mogenic reagents in the anti-interference performance.
3.Blood compatibility of an axial-flow blood pump made in China:Verifying observation
Changyan LIN ; Guanghui WU ; Bingyi LI ; Xiaotong HOU ; Jing WANG ; Xiangyue ZHOU ; Hongjiu PAN
Chinese Journal of Tissue Engineering Research 2007;11(48):9809-9812
BACKGROUND: Axial-flow blood pump is a main pump for ventricle assistance. Previous researches demonstrate that poor hemocompatibility of blood pump is an important factor for hemolysis and thrombus.OBJ ECTTVE: To design an axial-flow blood pump based on previous kinds of blood pumps through changing whole appearance and impeller shape of the pump by using Computer-Aided Design CAD) and Computational Fluid Dynamics (CFD), and manufacture it successfully.DESIGN: Rationality of theoretical design was verified by practical tests.SETTTNG: Beijing Anzhen Hospital of Capital University of Medical Sciences Department of Biomedical Engineering,Beijing Institute of Heart, lung and Blood Vessel Diseases; the Faurteenth Institute of China-Aerospace Science and Industry Corporation.MATERIALS: Body of blood pump and impeller were titanium alligation, and shaft bearing was ceramic. Test in vitro was accorded to artificial ventricular assist device which was provided by Department of Biomedical Engineering, Beijing Anzhen Hospital of Capital University of Medical Sciences. Experimental goats were provided by Experimental Animal Center, Beijing Anzhen Hospital of Capital University of Medical Sciences.METHODS: Since the beginning of 2005, a model of axial flow blood pump was designed in the 14th Institute of China-Aerospace Science and Industry Corporation base on decreasing shearing force and circulating dead bands. In the process, CAD and CFD were used to generate the geometrical data document of pump's structure, which included the figures of pump's body, shape and number of impeller's vanes, the structure and position of the guide vanes, and the size of impeller's screw-pitch. And then, NC machine tool was used for shaping. Finally, axial-flow blood pump was fixed on artificial ventricular assist device which was provided by Department of Biomedical Engineering, Beijing Anzhen Hospital of Capital University of Medical Sciences. The pump's hemodynamic output was 5 L/min and the average pressure was 13.3 kPa under the mixture of glycerin and water and fresh anticoagulation goat blood. The samples were collected at every one half hour during pumps being pumping for 4 hours. According to testing pressure output of blood pump, normalized index of hemolysis (NIH) was used to reflect content of free hemoglobin in plasma, observe thrombogenesis in pump and verify pump's hemodynamic output and vascular damaging degree.RESULTS: Shaped axial-flow blood pump included body, impeller, guide vanes, ceramic shaft bearing, export and import. The volume was 63 mL. Experimental results in vitro indicated that when the rotation speed of blood pump was 10 000 r/min, its pressure and flow output were 21.01 kPa and 6.0 L/min. The hemodynamic output might satisfy for left ventricular assistance. Surface temperature did not change obviously during successive rotation. The calculation indicated that most parts in blood pump showed a streaming flow. The mean NIH was (0.047±0.017) g/100 L, which was less than that of previous pumps; while, thrombogenesis was not observed in blood pump.CONCLUSTON: Axial-flow blood pump designed by using CAD and CFD can not only satisfy for the hemodynamics of a left ventricular assistant devices, but also the blood damage is milder than previous pumps. Therefore, axial-flow blood pump improves blood compatibility.
4.The research progress on role of miRNAs in methamphetamine addiction
Yongwang HE ; Juan LI ; Yiqing ZHOU ; Xiangyue ZHAO ; Genmeng YANG ; Ning ZHANG ; Xiaofeng ZENG ; Zhen LI
Chinese Pharmacological Bulletin 2017;33(8):1056-1060
The methamphetamine(METH)addiction is a compensatory adaptation of the central nervous system after the long-term exposure to METH in the molecular,cellular,neuronal loop function and brain structure.As a new type of post transcriptional regulatory molecules and regulatory factors,miRNAs are a large number of regulatory factors in the central nervous system.Studies have shown that miRNAs play an important role in the regulation of METH addiction.This paper is to review and summarize the expression features and the regulatory role of miRNAs in METH addiction,as well as the different expression of miRNAs in different tissues and organs.The aim of this paper is to provide a reference for further study on the role of miRNAs molecules in METH addiction and the discovery of new drug targets.
5.A single person operation procedure and experience of tail vein injection in conscious tree shrews
Yongwang HE ; Juan LI ; Jian HUANG ; Yiqing ZHOU ; Xiangyue ZHAO ; Genmeng YANG ; Zhen LI ; Na LI ; Xiaofeng ZENG
Chinese Journal of Comparative Medicine 2018;28(3):91-94
Objective To introduce a single person operation procedure for tail vein injection in conscious tree shrews,and to improve the success rate of injection. Methods The tree shrew was fixed by a canvas glove and a clamp. The tail of the tree shrew was fixed by the operator's left hand, and the drug was injected by the right hand with a 1 mL disposable syringe. Results This method had the advantages of simple operation,economy and practicality,good fixation effect,high matching degree of animals and high success rate of drug administration. Conclusions Compared with other methods,this method has obvious advantages such as single person operation, convenient, time-saving and labor-saving. The cost is low and the effect is good,thus significantly improving the success rate of injection.
6.Effectiveness of a whole-process health education model among inpatients with ascites type of advanced schistosomiasis
Rui-hong ZHOU ; Xun-ya HOU ; Xiang-hui CHENG ; Jie PAN ; Ru-yi LAI ; Gui-mei CHEN ; Hui ZHANG ; Lan-jun WEI ; Lu ZHANG ; Jia-xin LIU
Chinese Journal of Schistosomiasis Control 2022;34(6):626-629
Objective To evaluate the effectiveness of a whole-process health education model among inpatients with ascites type of advanced schistosomiasis. Methods A “admission-hospitalization-discharge” whole-process health education model was created, 101 inpatients with ascites type of advanced schistosomiasis were given the whole-process health education. The scores of schistosomiasis control knowledge, attitudes towards schistosomiasis control and healthy behaviors, and awareness of schistosomiasis control knowledge, correct rate of attitudes towards schistosomiasis control and correct rate of healthy behaviors were compared among inpatients with ascites type of advanced schistosomiasis before and after implementation of the whole-process health education. Results The scores of schistosomiasis control knowledge, schistosomiasis control attitudes and healthy behaviors were all significantly higher among inpatients with ascites type of advanced schistosomiasis after implementation of the whole-process health education than before implementation (Z = −7.688, −3.576 and −4.328, all P values < 0.01). In addition, the awareness of schistosomiasis control knowledge increased from 54.3% to 82.7% (χ2 = 188.886, P < 0.01), and the correct rate of attitudes towards schistosomiasis control increased from 88.4% to 98.0% (χ2 = 22.001, P < 0.01), while the correct rate of healthy behaviors increased from 48.2% to 59.7% (χ2 = 11.767, P < 0.01). Conclusions The whole-process health education model may remarkably improve the awareness of schistosomiasis control knowledge and promote the formation of positive attitudes towards schistosomiasis control and correct behaviors among inpatients with ascites type of advanced schistosomiasis, which is of great significance to facilitate patients’ cure.