1.MR cholangiopancreatography in comparison with ultrasound in the diagnosis of choiangiopancreatic disease
Jing WU ; Xiangke DU ; Qinchen QIANG
Chinese Journal of General Surgery 1993;0(02):-
Objective To evaluate the diagnostic value of MRCP compared with ultrasound in patients with cholangiopancreatic disease by ROC curve. Methods The data of 62 patients with suspected cholangiopancreatic disease undergoing both MRCP and ultrasound were retrospectively studied. ROC analysis was performed by ROCKIT software. Results Area under the ROC curve of MRCP was 0.739. Area under the ROC curve of US was 0. 930. ROC analysis showed that these two modalities were effective in diagnosing cholangiopancreatic disease, with MRCP being more effective than ultrasound, especially for the diagosis of lower biliary tract diseases. Conclusion MRCP combined with MRCP source images is of great help in the diagnosis of pancreaticobiliary duct diseases.
2.The clinical value of plasma D -D and blood glucose change in treating patients with bone trauma
Xiaohui MAO ; Wei XIE ; Xiangke WU ; Jianxin ZHANG
Chinese Journal of Primary Medicine and Pharmacy 2016;23(5):687-689,690
Objective To explore the clinical value of plasma D -D and blood glucose change in treating patients with bone trauma.Methods Selected 200 patients with bone trauma as the observation group,60 cases of healthy persons as the control group.The plasma D -D and blood glucose of the two groups were detected,and the results were analyzed.Results The plasma D -D and blood glucose of the observation group were more than those of the control group,and it was gradually reduced from first day to third day and fifth day.The plasma D -D of the observation group was (174.7 ±40.2)μg/L,blood glucose was (5.2 ±0.4)mmol/L.The plasma D -D of first day, third day and fifth day of the observation group were (1 452.6 ±303.4)μg/L,(982.2 ±215.2)μg/L,(705.6 ± 152.9)μg/L respectively.The blood glucose of first day,third day and fifth day of the observation group were (14.2 ±2.3)mmol/L,(10.3 ±1.2)mmol/L,(7.6 ±1.9)mmol/L,respectively.The difference was statistically sig-nificant(F =3.49,P <0.05).In the observation group,the more severe injury in patients,the higher plasma D -D and blood glucose,and it was gradually reduced from first day to third day and fifth day,the difference was statistically significant(F =4.83,P <0.05).Conclusion In judging the condition of bone trauma,it is important to measure plasma D -D and blood glucose levels,and this method should be popularized in clinical use.
3.Quality control and parameter optimization of coronary angiography with 64 multi-slice CT
Weiwei QI ; Jing WU ; Xiangke DU ; Jianying LI
Chinese Journal of Radiology 2000;0(12):-
Objective To control the image quality and to optimize the scan protocols of 64 multi-slice CT coronary imaging by analyzing factors that influence the image quality.Methods Seventy-eight patients with known or suspected CAD underwent CT coronary angiography using 64 multi-slice CT.The image quality in those cases was analyzed retrospectively to derive the optimized scan protocols.The application value of the override function was discussed.The dependency of cardiac reconstruction algorithms and corresponding image quality on patient heart rates was analyzed.In addition,the relationship between heart rate and the contrast-enhancement effect was studied.Results(1)Correct use of override function could improve the quality of cardiac images.(2)For patients with heart rates below 70 beats per minute,the image quality of single-segment reconstruction was satisfactory.For patients with heart rates between 70 and 79 beats per minute,the scores of images reconstructed with two-segments were better than that of single-segment reconstruction.(3)In the group with averaged heart rate of 60.7 beats per minute,the forecast contrast quantity of 70 ml was judged insufficient in 65.7%(23/35)cases;while for the group with averaged heart of 71.1 beats per minute,52.9%(18/34)cases were enhanced well.Conclusion The use of override function,correct segment mode and appropriate contrast quantity could be selected according to the heart rate,which could improve the image quality and reliability.