1.Role of elemene in Inhibiting tumor angiogenesis
Wei CAO ; Dan LI ; Xianghong YANG
Journal of International Oncology 2011;38(6):430-432
Elemene is a novel universal non-cytotoxic antitumor drug. Based on downregulation of VEGF expression, induction of apoptosis of vascular endothelial cells and suppression of growth of tumor cell, elemene is becoming helpfully a promising inhibitor of angiogenesis, however, the detail mechanisms remains unclear and needs to be further elucidated.
2.Expression of heat shock protein 27 mRNA in the carcinogenesis of esophageal squamous epithelium
Fumin CAO ; Xianghong ZHANG ; Lingxiao XING
China Oncology 2001;0(02):-
0.05). Conclusions:Compared with normal esophageal mucosa, the expression of HSP27 mRNA in esophageal squamous carcinoma and mucosa with atypical hyperplasia was markedly decreased.This indicated that the expression of HSP27 mRNA to a greater or less extent lost in the carcinogenesis and development of esophageal squamous carcinoma. To up-regulate the expression of HSP27 mRNA in esophageal squamous carcinoma may be a very effective biological therapy.
3.Study of effects of the thoracic pressure on the velocity of tricuspid regurgitation and estimation of pulmonary artery systolic pressure
Huaqiang XIONG ; Tiesheng CAO ; Xianghong LUO ; Lijun YUAN ; Yunyou DUAN
Chinese Journal of Ultrasonography 2009;18(4):284-287
Objective To observe the effects and the mechanism of the thoracic pressure variation on the velocity of tricuspid regurgitation in quiet respiration, to accurately estimate the pulmonary artery systolic pressure,and to verify the new proposed mechanism of respiration effects on hemodynamics using echocardiography. Methods Continuous-wave Doppler spectra of tricuspid regurgitation were recorded with Sequoia 512 in 50 patients who had stable tricuspid regurgitation. Electrocardiogram and respiratory tracing were recorded simultaneously. The velocities and the pressure gradients were recorded during different respiration phases for analyzing. Results Respiration reliably affected on tricuspid regurgitant velocity. There were three patterns of manifestation:①The velocity increased in the inspiratory phase. ②The velocity decreased in the inspiratory phase. ③The velocity changed randomly. Conclusions Thoracic pressure variations had definite effects on the velocity of tricuspid regurgitation and tricuspid gradient. This research indicated that to obtain accurate and reliable Doppler echocardiographic measurement of the pulmonary artery systolic pressure, the measurement should be at the time between inspiration and expiration.
4.Research in deformation and motion of interventricular septum by velocity vector imaging combining with radius of curvature and length of arc
Xianghong LUO ; Tiesheng CAO ; Zuojun WANG ; Yunyou DUAN ; Zhaojun LI
Chinese Journal of Ultrasonography 2009;18(3):219-221
Objective Radius of curvature (RC) and velocity vector imaging (VVI) were joined to evaluate the deformation and motion of interventricular septum(IVS). Methods VVI was performed in fifteen healthy volunteers and obtained dynamic images at chordae tendineae of mitral valve in short axis view. The images were stored and analyzed to obtain circumferential peak stain of IVS. In the same short axis view, the static images were captured at end-systole and end-diastole respectively before they were analyzed by self-made software. The length of arc and RC were measured automatically by the software, so the shortening rates of them could were calculated. Results The length of arc and RC were longer at end-diastole than those at end-systole(P<0.0001). The shortening rate of length of arc was compared with circumferential peak stain of IVS (P=0.123) and they were correlation (r = 0. 840, P = 0. 0001 ). Blant-Altman analysis indicated that the concordance was well. Conclusions The length of arc and RC can evaluate the deformation and motion of IVS.
5.A new way to study the motion of interventricular septum by echocardiography
Xianghong LUO ; Tiesheng CAO ; Yunyou DUAN ; Zhaojun LI
Chinese Journal of Ultrasonography 2009;18(2):93-95
Objective To evaluate the effect of normal respiration on motion and disfiguration of interventricular septum (IVS) by observing the change of interventricular septum radius of curvature (IVSRC). Methods The 2D short-axis images at chordae tendineae of mitral valve were recorded during inspiration and expiration respectively by Acuson Sequoia 512 in 21 normal subjects. Speed of blood flow of each valve, electrocardiogram and respiratory tracing were recorded simultaneously. Two doctors who were double-blind measured the IVSRC using self-designed software. Results During normal inspiration, the peak E velocity of mitral valve and the flow velocity of aortic valve decreased,while the peak E velocity of tricuspid valve and the flow velocity of pulmonary valve increased. The IVSRC curvatures were (25.914± 6.082)mm during inspiration, and (22.296±4.398)mm during expiration, there was difference in two respiration phases(P <0.0001). Conclusions IVSRC can be used to evaluate motion and disfiguration of IVS. It has a good repeatability and is an effective way to observe the change of pleural pressure which is produced by respiration.
6.Significance of new parameters in evaluation the function of carotid artery
Xianghong LUO ; Tiesheng CAO ; Jie LIU ; Yunyou DUAN ; Zhaojun LI
Chinese Journal of Ultrasonography 2009;18(9):759-761
Objective To evaluate the parameters of inner diameter different rate (D%), mean wave intensity(MWl) and diameter-adjusted mean wave intension(DAMWI) in assessing the function of common carotid artery(CCA) by quality intima-media thickness(QIMT) technique. Methods Twenty-four healthy subjects were performed 2D and CDFI examination under the normal quiescent and cold pressor test(CPT) condition respectively. The diastolic and systolic diameters of left-CCA were measured by QIMT respectively. Corresponding the inner diameter different range,rate,MWI and DAMWI were calculated respectively. The curves of their ROC were drawn. Results The different range and rate of diameters were decreased when subjects suffered CPT (P< 0.05) ,but the MWI and DAMWI were increased (P<0. 05). The areas under the ROC curves were 0. 827,0. 821 and 0.728 corresponding DAMWI, MWl and different rate of diameter. There was no significant difference among them(P>0. 05). Conclusions Conclusions The changed rate of diameter can be measured exactly by QIMT. The function of CCA can Be evaluated by MW1 and DAMWI which were calculated by conventional parameters.
7.Comparison of the Test Results between Automatic Enzyme-linked Immunity Analyzer and Manual Enzyme-linked Immunoassay
Shenghu WANG ; Xianghong CAO ; Yuan LI ; Qi CHEN
Journal of Kunming Medical University 2016;37(10):96-99
Objective To compare the consistency of the results of clinical specimens between Tecan Freedom Evolyzer-2200 automated enzyme immunoassay analyzer and manual ELISA method,so as to explore more scientific and reliable test method.Methods Ninety samples were randomly selected from clinical and physical examination,the IMARK2 microplate reader and the instrument operating manual sample measurement was used to test hepatitis A,hepatitis B 5,hepatitis C,hepatitis E 2,TP and HIV,and the results were given correlation and linear regression analysis.Results For the test items of HBsAg,HBsAb,HBeAg,TP,HIV,the correlation coefficient was r2> 0.9,the data showed a good correlation,and for HAV-IgM,HBeAb,HBcAb,HCV,HEV-IgM,HEV-IgG,the correlation coefficient was 0.9> r 2 > 0.6.Compared with manual method,the total coincidence rate of automated enzyme immunoassay analyzer was 96.9% in 11 indexes of 90 samples.Conclusions Automatic and manual ELISA method has a good correlation.Automatic ELISA also greatly reduce the labor burden of laboratory personnel,improve efficiency,should be strengthened in clinical practice.
8.Comparative research on application between power peripherally inserted central catheters and double cavity central venous catheter with the patients in intensive care unit
Xiuzhu CAO ; Linfang ZHAO ; Limin HUANG ; Yaping WANG ; Xianghong JIN
Chinese Journal of Practical Nursing 2015;31(34):2579-2583
Objective To compare the safety and effectiveness of power peripherally inserted central catheters (Power PICC) and double cavity central venous catheter (CVC) application in intensive care unit (ICU). Methods 458 cases were reviewed during January to September in 2014 and divided into two groups: Power PICC group (245 cases) and CVC group (213 cases) , and average retention time, successful rate of inserting catheter and the incidence of complications were compared. Results The average retention time of Power PICC group was (21.6±5.8) days which was longer than (13.1±3.4) days of CVC group (t=2.234, P <0.05). No statistics difference of successful rate between two groups (P>0.05). No significant difference for the total incidence of complications between two groups as 14.69% (36/245) and 19.72%(42/213)(P>0.05). No significant difference for the total incidence of complications in the operation time between two groups as 5.31% (13/245) and 4.23% (9/213)(P>0.05). But rate of catheter malposition for Power PICC group [ 2.86% (7/245) ] was higher than CVC group 0 (X2=4.428, P <0.05). Rate of the total incidence of complications in the retention time Power PICC group [ 9.39%(23/245) ] was lower than CVC group [ 15.96%(33/213)(P<0.05). And rate of catheter related blood stream infection of CVC group [3.29%(7/213)] was much more higher than Power PICC group (0)(X2=6.139,P<0.05). Conclusions Power PICC and CVC are both applicable for ICU, and Power PICC has more advantage regarding safety and effectiveness than CVC and can be one replacement for CVC.
9.Application of MWI-a new parameter of wave intensity
Xianghong LUO ; Zhaojun LI ; Tiesheng CAO ; Yunyou DUAN ; Jie LIU
Chinese Journal of Medical Imaging Technology 2010;26(1):60-62
Objective To investigate the feasibility of mean wave intensity (MWI), W1 and W2 in assessing the function of common carotid artery (CCA) before and after cold presser test with wave intensity analysis. Methods Twenty-four healthy subjects were enrolled. The W1, W2, and other parameters of blood flow in resting, before and after cold presser test of CCA, the inner diameter different rate and MWI of blood flow were calculated respectively. The receiver operation characteristic (ROC) curves were drawn, and of the effectiveness of MWI, W1 and W2 was compared. Results The different rate of diameters and W1 decreased significantly when subjects underwent cold presser test (P<0.05), but MWI and W2 increased significantly (P<0.05). The area under ROC curves was 0.858, 0.731 and 0.698, corresponding to MWI, W1 and W2 (P>0.05). Conclusion The function of CCA can be evaluated with MWI calculated from conventional parameters.