1.Prospective evaluation of point-of-care ultrasound for pre-procedure identification of landmarks versus traditional palpation for lumbar puncture
Lahham SHADI ; Schmalbach PRIEL ; Wilson P. SEAN ; Ludeman LORI ; Subeh MOHAMMAD ; Chao JOCELYN ; Albadawi NADEEM ; Mohammadi NIKI ; Fox C. JOHN
World Journal of Emergency Medicine 2016;7(3):173-177
BACKGROUND: The objective of this study is to determine if point-of-care ultrasound (POCUS) pre-procedure identification of landmarks can decrease failure rate, reduce procedural time, and decrease the number of needle redirections and reinsertions when performing a lumbar puncture (LP).METHODS: This was a prospective, randomized controlled trial comparing POCUS pre-procedure identifi cation of landmarks versus traditional palpation for LP in a cohort of patients in the emergency department and intensive care unit.RESULTS: A total of 158 patients were enrolled. No signifi cant difference was found in time to completion, needle re-direction, or needle re-insertion when using POCUS when compared to the traditional method of palpation.CONCLUSION: Consistent with fi ndings of previous studies, our data indicate that there was no observed benefi t of using POCUS to identify pre-procedure landmarks when performing an LP.
2.Point-of-care ultrasound versus radiology department pelvic ultrasound on emergency department length of stay
Wilson P. SEAN ; Connolly KIAH ; Lahham SHADI ; Subeh MOHAMMAD ; Fischetti CHANEL ; Chiem ALAN ; Aspen ARIEL ; Anderson CRAIG ; Fox C. JOHN
World Journal of Emergency Medicine 2016;7(3):178-182
BACKGROUND: The study aimed to compare the time to overall length of stay (LOS) for patients who underwent point-of-care ultrasound (POCUS) versus radiology department ultrasound (RDUS).METHODS: This was a prospective study on a convenience sample of patients who required pelvic ultrasound imaging as part of their emergency department (ED) assessment.RESULTS: We enrolled a total of 194 patients who were on average 32 years-old. Ninety-eight (51%) patients were pregnant (<20 weeks). Time to completion of RDUS was 66 minutes longer than POCUS (95%CI 60–73,P<0.01). Patients randomized to the RDUS arm experienced a 120 minute longer ED length of stay (LOS) (95%CI 66–173,P<0.01)CONCLUSION: In patients who require pelvic ultrasound as part of their diagnostic evaluation, POCUS resulted in a signifi cant decrease in time to ultrasound and ED LOS.
3.Simplified point-of-care ultrasound protocol to confirm central venous catheter placement:A prospective study
Wilson P. SEAN ; Assaf SAMER ; Lahham SHADI ; Subeh MOHAMMAD ; Chiem ALAN ; Anderson CRAIG ; Shwe SAMANTHA ; Nguyen RYAN ; Fox C. JOHN
World Journal of Emergency Medicine 2017;8(1):25-28
BACKGROUND: The current standard for confirmation of correct supra-diaphragmatic central venous catheter (CVC) placement is with plain film chest radiography (CXR). We hypothesized that a simple point-of-care ultrasound (POCUS) protocol could effectively confirm placement and reduce time to confirmation. METHODS: We prospectively enrolled a convenience sample of patients in the emergency department and intensive care unit who required CVC placement. Correct positioning was considered if turbulent flow was visualized in the right atrium on sub-xiphoid, parasternal or apical cardiac ultrasound after injecting 5 cc of sterile, non-agitated, normal saline through the CVC. RESULTS: Seventy-eight patients were enrolled. POCUS had a sensitivity of 86.8% (95%CI 77.1%–93.5%) and specificity of 100% (95%CI 15.8%–100.0%) for identifying correct central venous catheter placement. Median POCUS and CXR completion were 16 minutes (IQR 10–29) and 32 minutes (IQR 19–45), respectively. CONCLUSION: Ultrasound may be an effective tool to confirm central venous catheter placement in instances where there is a delay in obtaining a confirmatory CXR.
4.Procedural simulation: medical student preference and value of three task trainers for ultrasound guided regional anesthesia
Lahham SHADI ; Smith TAYLAUR ; Baker JESSA ; Purdy AMANDA ; Frumin ERICA ; Winners BRET ; Wilson P. SEAN ; Gari ABDULATIF ; Fox C. JOHN
World Journal of Emergency Medicine 2017;8(4):287-291
BACKGROUND: Ultrasound guided regional anesthesia is widely taught using task trainer models. Commercially available models are often used; however, they can be cost prohibitive. Therefore, alternative "homemade" models with similar fidelity are often used. We hypothesize that professional task trainers will be preferred over homemade models. The purpose of this study is to determine realism, durability and cleanliness of three different task trainers for ultrasound guided nerve blocks. METHODS: This was a prospective observational study using a convenience sample of medical student participants in an ultrasound guided nerve block training session on January 24th, 2015. Participants were asked to perform simulated nerve blocks on three different task trainers including, 1 commercial and 2 homemade. A questionnaire was then given to all participants to rate their experiences both with and without the knowledge on the cost of the simulator device. RESULTS: Data was collected from 25 participants. The Blue Phantom model was found to have the highest fidelity. Initially, 10 (40%) of the participants preferred the Blue Phantom model, while 10 (40%) preferred the homemade gelatin model and 5 (20%) preferred the homemade tofu model. After cost awareness, the majority, 18 (72%) preferred the gelatin model. CONCLUSION: The Blue Phantom model was thought to have the highest fidelity, but after cost consideration the homemade gelatin model was preferred.