1.Evaluation of biocompatibility of fiber-reinforced dental composites
Wenyun ZHANG ; Yi SHEN ; Nan LI
Medical Journal of Chinese People's Liberation Army 1981;0(04):-
Objective To evaluate the biological compatibility of dental nano-silicon dioxide/high-strength-glass fiber/EAM resin composites(FRC). Methods Experiments of general acute toxicity, cytotoxicity, hemolysis and mucous membrane irritation were performed on the newly developed FRC. Results The newly developed FRC induced no cytotoxicity, hemolysis, acute toxicity or mucous membrane irritation. Conclusion The newly developed FRC has good biocompatibility in vitro and vivo.
2.Study of technical method of immunohistochemical staining in pathological tissue
Wenyun ZHANG ; Jinjing LV ; Yan ZHOU
Chinese Journal of Biochemical Pharmaceutics 2017;37(7):40-42
Objective To study the technical method of immunohistochemical staining in pathological tissue.Methods 80 cases of hospitalized patients in our hospital from May 2015 to May 2016 were selected, they were randomly divided into immunohistochemical staining group(immunohistochemistry group, n=40)and biopsy group(n=40)two groups, then the AFP(alpha-Fetoprotein), Glypican-3 positive situation of the the two groups and diagnostic Resultsof patients with different types of disease in the immunohistochemistry group were statistically analyzed.ResultsThe positive rate of AFP(a-Fetoprotein), Glypican-3 of the immunohistochemistry group 92.5%(37/40)was significantly higher than the biopsy group 50.0%(20/40)(P<0.05), Among the 37 cases of positive patients, metastatic tumors 19 cases, hepatocellular carcinoma 9 cases, intrahepatic bile duct carcinoma 7 cases, hemangioma 3 cases, the positive rates were 100.0%, 75.0%, 100.0%, 100.0%, 26 cases died, the mortality rate was 70.3%, of which metastatic tumors 13 cases, hepatocellular carcinoma 6 cases, intrahepatic bile duct carcinoma 5 cases, hemangioma 2 cases, the mortality rates were 72.2%, 66.7%, 71.4%, 66.7%.Conclusion Immunohistochemical staining technic in pathological tissue can promote positive rate, and standard operation procedures can reduce errors, which is worthy of clinical attention.
3.Fracture resistances of pulpless teeth restored with two kinds of cast metal post-core or glass-fiber post with a composite core
Wenyun ZHANG ; Changxi SHI ; Jihua CHEN
Journal of Practical Stomatology 2000;0(05):-
Objective: To compare the fracture resistance of pulpless teeth restored with three types of post core.Methods: A total of 21 recently extracted sound upper incisors were randomly distributed into 3 groups. In group A the teeth were restored with prefabricated glass fiber post and composite core; in group B with custom cast titanium alloy post and core; and in group C with Ni Cr alloy dowel core. The size and shape of posts were identical in the 3 groups. All teeth were fully covered with Ni Cr alloy cast crown. Fracture resistance was measured by applying a point force at 130 degrees to the long axis of the teeth. Results: Mean fracture threshold was (276.6?15.1)N in group A, (394.7?29.1)N in group B and (373.4? 53.8 )N in group C. In group B and C, however, fracture always affected the tooth itself,whereas in group A,the core always failed first. Conclusion: Fiber reinforced composite(FRC) post may meet the clinical need, FRC post combined with composite core may prevent tooth root from fracture.
4.Minimal diameter of the fistula vein defines a significant stenosis in an autologous arteriovenous fistula
Yuankai XU ; Jingqin ZHEN ; Wenyun ZHANG ; Qingqing DUAN ; Lihong ZHANG
Chinese Journal of Nephrology 2017;33(3):187-190
Objective To define a parameter of autologous arteriovenous fistula stenosis that limits the fistula function for hemodialysis in our country.Methods Retrospectively study the doppler ultrasound of patients who accepted the percutaneous transluminal angioplasty (PTA) therapy due to autogenous arteriovenous fistula dysfunction;identify the least diameter of the fistula vein and compare it with the corresponding data of well-functioned fistula.Determine which absolute diameter constitutes a hemodynamically significant stenosis in a radioeephalic autologous arteriovenous fistula by receiver operating characteristic curve (ROC curve).Result Forty-two patients were enrolled in the study.The average age of those patients was 54.63±2.44 years old.Twenty-one patients were female.Twenty-six fistula located on the left arm.The minimal diameter of the dysfunction fistula averaged 1.57±0.07 mm,while the average forearm fistula vein diameter was 4.04±0.23 mm,significantly smaller than those in the compare group-an average minimal fistula vein diameter of 3.34±0.11 mm and a forearm vein diameter of 5.36(4.52,6.45) mm (P < 0.05).The control group contained sixty-eight patients.The average age of those patients was 52.56±2.00 years old.Thirty-one patients were female.Forty-nine fistula located on the left arm.It was quiet appropriate in using minimal diameter of the fistula vein to indicate the dysfunction istula with an under-curve area of 0.979,95%C1 0.959-0.998.The under-curve area would be at the largest level when meeting the cutoff point at 2.40mm,in which it could achieve the area of 0.853.Conclusions The minimal diameter of the dysfunction wrist autogenous arteriovenous fistula was much smaller than the functioned ones.Minimal diameter of the fistula vein may serve as an effective parameter in detecting dysfunction fistula.
5.Research on adhesive strength of different composites resin core and fiber posts
Wenyun ZHANG ; Ting FENG ; Lidou YANG ; Xinxiao LUO ; Yuhong XIAO
Journal of Practical Stomatology 2009;25(4):475-478
Objective:To study the adhesive strength between fiber posts and four different composite resin core materials.Methods:Four resin core materials (Multicore Heavy Body、LuxaCore、 LIGHT-CORE and Z100) were placed around the fiber posts. The adhesive strengths of the samples were tested by the universal electrical testing machine. The interface between fiber post and resin core was observed by SEM. Results:Different resin core materials exhibited significant different influences on adhesive strengths(P<0.05). The LuxaCore reached the maximum of (314.31±15.36) N and the Z100 was the minimum of (267.39±10.54) N.Conclusion:Resin core material exhibits a significant influence on adhesive strength. The dual-curing composite core material with low viscosity has the highest bond strength in all groups.
6.Characters and influential factors of vascular remolding after native arteriovenous fistula
Yuankai XU ; Lihong ZHANG ; Wenyun ZHANG ; Ziqiang WANG ; Qiongzhen LIN ; Baoxing WANG ; Ying LI
Chinese Journal of Nephrology 2014;30(6):424-428
Objective To finding out the characters of vascular remolding after the establishment of native arteriovenous fistula on the wrist,and exploring the influential factors.Methods Doppler ultrasound was used to monitor the diameter of cephalic vein,brachial artery,radial artery and ulnar artery at the time before the surgery and one day,one week,two weeks,four weeks and eight weeks after the surgery respectively.The tendency of the diameter change was analyzed.Results Twenty eight patients completed the whole monitor session,in which eleven were female.The average age of those patients was (53.68 ± 2.61) years old.Twelve of them were diabetic nephropathy.The diameters of all vessel were increased more rapidly at the first day than any other days after surgery(all P < 0.01).The patients were divided into two groups depending on whether diabetic nephropathy.No significant difference was found between the two groups on the tendency of diameter change in cephalic vein and brachial artery (all P > 0.05).However,the tendency of diameter change in radial artery and ulnar artery was statistically significant difference between the two groups (all P < 0.05).Conclusions Cephalic vein,brachial artery,radial artery and ulnar artery are all apparently dilated on the first day after the surgery.The vascular dilation and diameter increasing become much slower after the period,the diameter tend to be stable.The primary diseases may affect the tendency of the diameter change in radial artery as well as ulnar artery.
7.Effect of NUP88 gene on proliferation and invasion biological behavior of breast cancer cell line BT-20
Mingli GUAN ; Ren ZHOU ; Huajuan RUAN ; Wenyun ZHANG ; Xiaomin HU ; Hongjiao ZHANG
Chinese Journal of Immunology 2017;33(9):1326-1330,1335
Objective:To observe the effect of low-expression or over-expression of NUP88 gene on the proliferation and invasion ability of breast cancer cell line BT-20.Methods: NUP88 recombinant adenovirus expression vector and NUP88 RNAi adenovirus vector were transfected into breast cancer BT-20 cells to obtain BT-20 cells over-expressing NUP88 and BT-20 cells lower-expressing NUP88 and then detected the expression of NUP88 mRNA and NUP88 protein.After that,the apoptosis of BT-20 cells was detected by flow cytometry and the invasion and metastasis of BT-20 cells were detected by Transwell invasion assay.The expression of apoptosis protein and invasion and metastasis proteins were detected by Western blot.Results: BT-20 cell with the over expression levels of NUP88 mRNA and NUP88 protein and BT-20 cell with the low expression levels of NUP88 mRNA and NUP88 protein were structured.The over-expression of NUP88 gene led to proliferation rate and the number of invasive cells were significantly higher than BT-20 cells,apoptosis cells were significantly lower than BT-20 cells(P<0.05).However,the low-expression of NUP88 gene led to proliferation rate and the number of invasive cells were significantly lower than BT-20 cells,apoptosis cells was significantly higher than BT-20 cells(P<0.05).The over-expression of NUP88 gene led to Bcl-2 and β-catenin level were significantly higher than that of BT-20 cells,and Bax and E-cadherin level were significantly lower than that of BT-20 cells(P<0.05).However,the low-expression of NUP88 gene led to Bcl-2 and β-catenin level were significantly lower than that of BT-20 cells,and Bax and E-cadherin level were significantly higher than that of BT-20 cells(P<0.05).Conclusion: NUP88 gene regulates the proliferation and invasion and migration ability of breast cancer cells by regulating the expression of Bax,Bcl-2,E-cadherin and β-catenin.It has an important significance in the target treatment of breast cancer.
8.Relation between autogenous arteriovenous fistula diameter and hemodynamic parameter
Yuankai XU ; Lihong ZHANG ; Yixin ZHAO ; Wenyun ZHANG ; Qingqing DUAN ; Ying LI
Chinese Journal of Nephrology 2016;32(7):494-501
Objective To analyze the relationship between the least diameter of autogenous arteriovenous fistula and other parameters like flow rate and artery diameter. To identify an appropriate way in defining fistula stenosis. Methods Physical examination and Doppler ultrasound were used to examine the autogenous arteriovenous fistula of maintenance hemodialysis patients. Well?used wrist arteriovenous fistula was included. The least diameter of the fistula vein was found and marked by ultrasound, and the diameter and the distance between the point and the anastomotic stoma were measured. Diameters of different places along the cephalic vein of the fistula, including the forearm place, the place close to elbow and the upper arm place were measured by ultrasound. Meanwhile, diameter as well as flow velocity and flow rate of brachial artery, radial artery and ulnar artery were also measured. Result Sixty?eight patients were enrolled in the study. The average age of those patients was 52.56 ± 2.00 years old. Thirty?one patients were female. Forty?nine fistula were located on the left arm. The average diameter and flow rate of brachial artery were 5.72(5.34, 6.33) mm and 821.50 (540.50, 1075.00) ml/min, respectively. The average diameters of radial artery and ulnar artery were 3.95 ± 0.10mm and 3.17(2.73,3.75) mm, respectively. The least diameter of cephalic vein was 3.34 ± 0.11mm in average. The distance between the least place to the anastomotic stoma was 3.76±0.14cm in average. The diameter of forearm cephalic vein was averaged 5.36(4.52, 6.45) mm. Diameter of place close to elbow and the upper arm place in the cephalic vein were (5.57±0.12) mm and (5.80±0.14) mm, respectively. The least diameter of cephalic vein was positively and statistically associated with the diameter and flow rate of brachial artery as well as radial artery. The least diameter was also positively and statistically associated with the diameter of each place in the cephalic vein. Statistical inter?group difference was found when the division was based on the value of the least diameter. Conclusion sThe least diameter of the wrist autogenous arteriovenous fistula vein will indeed affect the whole diameter and flow rate of the fistula. The value of the least diameter is more closely associated with the fistula function rather than narrow rate.
9.Primary study in maturity status of native arteriovenous fistula on the wrist
Yuankai XU ; Lihong ZHANG ; Wenyun ZHANG ; Qingqing DUAN ; Qiongzhen LIN ; Ying LI
Chinese Journal of Nephrology 2014;30(11):841-845
Object To investigate the maturity status of the cephalic vein when the native arteriovenous fistula matures and set up indicators of a matured native arteriovenous fistula.Methods The diameter,flow rate and wall thickness of the cephalic vein were prospectively measured by Doppler ultrasound after the native fistula was created.Mature judgment was done by skilled nurses depending on their experience before the fistula was punctured.The ultrasound data was marked as proposed mature at the same time.After three times dialysis,if blood flow was fluent and complications such as prolonged bleeding time and hematoma were absent,fistula mature was confirmed.Results Thirty-one patients were admitted to the study,then fistula were matured.The average age of those patients was (52.93±3.21) years old.Thirteen patients were female.Twenty two fistula located on the left arm.Thirteen of the patients were diabetic nephropathy.The average diameter of cephalic vein was increased from (3.10±0.11) mm before surgery to (4.74±0.16) mm when the fistula was matured,though it was still smaller than 6 mm which K/DOQI guideline had recommended (P < 0.05).The average mature period was (57.10±3.21) days.The matured fistula had an average high flow rate of (569.76±48.34) ml/min and wall thickness of (0.95±0.04) mm.The one-side 95% credibility interval of the diameter,flow rate and wall thickness of cephalic vein was 4.44 mm,486.37 ml/min and 0.67 mm,respectively.Conclusions The diameter of cephalic vein in a matured native arteriovenous fistula in our study was significantly smaller than 6 mm which K/DOQI guideline had recommended.The indicators of native arteriovenous fistula mature in our country may different from abroad.
10.The influencing factors and methodological evaluation on tigecycline susceptibility testing methods for Acinetobacter baumannii and Klebsiella pneumoniae
Jixia ZHANG ; Chunjiang ZHAO ; Wenyun LIU ; Wei YAN ; Qiusheng PENG ; Zhanwei WANG ; Hui WANG
Chinese Journal of Laboratory Medicine 2013;36(7):604-609
Objective To investigate the factors affecting the susceptibility of tigecycline and assess the testing methods.Methods The 116 isolates of Acinetobacter baumanaii and Klebsiella pneumoniae were collected in 13 hospitals from January to December,2010,to evaluate the effects on the tigecycline susceptibility of the overnight medium,medium brand and lot number,respectively.The 56 isolates of Acinetobacter baumannii and the 47 isolates of Klebsiella pneumoniae were selected randomly according to the MIC distribution proportion in 2010 and 2012.The broth microdilution was taken as the reference method to evaluate the effects of the agar dilution,disk diffusion,MIC Test Strip (MTS) and Vitek2 (GN16) on the susceptibility of tigecycline.Results The essential agreement (EA) of Acinetobacter baumannii and Klebsiella pneumoniae is 89.7% (52/58)and 87.9% (51/58) using overnight medium and fresh medium respectively.Both EA and categorical agreement (CA) of the different brands (BBL and Oxoid) and lot numbers are 100% using agar dilution.According to the FDA break point criteria,the CA/EA is 77.7% (80/103)/99.0% (102/103),87.4% (90/103)/98.1% (101/103),64.1% (66/103)/76.7% (79/103) using agar dilution,MTS,Vitek (GN16) with respect to broth microdilution.The CA is 79.6% (82/ 103,S≥14 mm,R≤10 mm),69.9% (72/103,S≥ 16 mm,R≤ 12 mm),34.0% (35/103,S≥19 mm,R≤14 mm)using disk diffusion method compared with broth microdilution (FDA break point criteria).Conclusions The susceptibility of tigecycline must be tested using fresh medium.The medium brands and lot numbers used in this test have no effects on the tigecycline susceptibility to Acinetobacter baumannii and Klebsiella pneumoniae.There exist the better correlations on MIC using agar dilution and MTS than the disk diffusion and Vitek(GN16) compared with broth microdilution.It is expected that the consistency can be improved by adjusting the break point of disk diffusion.