1.Regimens for inoperable locally advanced non-small cell lung cancer
Jiang XI ; Wenhui LI ; Li WANG
Journal of International Oncology 2014;41(4):279-282
Concurrent chemoradiotherapy is the optimal regimen for patients with inoperable locally advanced non-small cell lung cancer (LA-NSCLC).The application of new technologies such as positron emission tomography (PET)/CT and four dimensional CT (4D-CT) enhances the accuracy of radiotherapy and decreases adverse reaction.Induction chemotherapy and consolidation chemotherapy do not show benefit to survival.The targeted therapy and immunotherapy have the potential of improving the outcomes of inoperable LA-NSCLC.
2.Maintenance treatment of advanced non-small cell lung cancer
Kunxiang LYU ; Wenhui LI ; Yu HOU ; Ming ZHANG ; Li WANG ; Jiang XI
Journal of International Oncology 2014;41(4):283-285
Currently platinum-based double chemotherapy is the standard first-line treatment for advanced non-small cell lung cancer (NSCLC).When the disease is under control,the next step after a standard course of chemotherapy is controversial,and maintenance treatment is used in the treatment of advanced NSCLC increasingly.Maintenance treatment of advanced NSCLC includes continue maintenance treatment and medication changed maintenance therapy.currently used for maintenance therapy with pemetrexed and erlotinib are shown to improve overall survival,which are usually used for maintenance treatment.
3.Enantioseparation of 38 Racemates on Four Chiral Columns in High Performance Liquid Chromatography
Mei ZHANG ; Wenhui XI ; Min ZI ; Ya PENG ; Shengming XIE ; Liming YUAN
Chinese Journal of Analytical Chemistry 2010;38(2):181-186
The enantioseparations of 38 racemates on Chiralcel OD, Chiralpak AD, Chiralpak IA and(S, S)-Whelk-01 were presented by HPLC. Those enantiomers come from the amines, alcohols, ethers, ketones, aromatic derivatives, heterocyclic compounds, amide acids and medicines etc. With the mobile phase of n-hexane)/isopropanol(90∶ 10, V/V), n-hexane/isopropanol/trifluoracetic acid(90∶ 10∶ 0.2, V/V) or n-hexane/isopropanol/triethylamine(90∶ 10∶ 0.2, V/V), over 70% enantioseparations were obtained for OD, AD and IA columns). The order of enantioseparation selectivity for four columns was OD>AD>IA>(S,S)-Whelk-01, and among those columns there was a big chiral discriminating complementarity. This investigation was useful for choosing chiral columns to separate chiral compounds.
4.Influence of aorta arch hematoma in endovascular repair of complex Stanford B intramural aortic hematoma
Hao LIU ; Xiaoyong HUANG ; Wenhui WU ; Xi GUO ; Guangrui LIU ; Xiaofeng HAN ; Lianjun HUANG
Chinese Journal of Interventional Cardiology 2017;25(8):452-456
Objective To investigate the influence of the hematoma involving the aortic arch in endovascular aortic repair of complicated type B intramural aortic hematoma. Methods A total of 69 patients[58men; mean age(58.1±8.9)years; range 38-77]underwent endovascular repair between February 2011 and June 2015 were retrospectively reviewed. Patients with hematoma involving about the left subclavian artery level were categorized as group A(n=28) and patients without hematoma involvement to the aortic arch were categorized as group B (n=41). Results All the patients were treated with coverd aortic stents. The success rate was 97.1% with complete isolation of lesion in 67 patients. The average follow-up period was(19.6±14.1)months. During perioperative period, no procedure related deaths was recorded. Perioperative complications include paraplegia in 1case(1.4%) in group B and stent graft-induced new entry in 2 cases(2.9%) in group A. During the follow-up period 1 case in group A within 1 month and another 1 case in group B within 1 year developed new entries at proximal end of stents. 1 case (1.4%) in group B had asymptomatic type Ⅰ endoleak 2 years after TEVAR. Conclusions Type B aortic intramural hematoma with arch involvement is not a risk factor of stent-induced new entry in perioperative period after endovascular treatment and further studies are needed. Strict control of blood pressure is essential for the prevention of stent-related complications.
5.The reliable treatment choice of nasopharyngeal angiofibroma and causes of operative bleeding.
Gongbiao LIN ; Chang LIN ; Zixiang YI ; Zheming FANG ; Xi LIN ; Wenhui XIAO ; Zhichun LI ; Jinmei CHENG ; Aidong ZHOU ; Shuzhan LAN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(11):770-775
OBJECTIVE:
To introduce the efficacy of three surgical options for juvenile nasopharyngeal angiofibroma (JNA) resection, and causes of operative bleeding.
METHOD:
Retrospective analysis of 36 JNAs,three surgical options were used to resect the tumor. There were 15 cases of Class I tumors , using endoscopic nasal cavity approach. Eighteen cases of class II tumors, via extended Caldwell-Luk incision, using the transantral-infratemporal fosse-nasal cavity combined approach for tumor resection. Three cases of class III tumors, the combined intracranial and extra-cranial approach was used to resect the tumor. Meanwhile, report six typical cases for reference.
RESULT:
Fifteen (15/36) cases of class I tumors, 14 cases were completely resected for the first time without recurrence, 1 recurrence case was re-resected using the same approach. Eighteen (18/36) cases of class II tumors, 13 cases were completely resected for the first time without recurrence, 5 recurrence cases were re-resected totally. Three (3/36) cases of class III were not completely removed, and underwent about 40 Gy radiotherapy with good effects.
CONCLUSION
Using these three surgical options can effectively remove different types of JNA. When necessary, the intracranial residue can use radiotherapy. Under direct vision to separate the tumor, and effective hemostasis play crucial roles for complete removal of the tumor.
Adolescent
;
Angiofibroma
;
surgery
;
Blood Loss, Surgical
;
Child
;
Female
;
Humans
;
Male
;
Nasopharyngeal Neoplasms
;
surgery
;
Retrospective Studies
;
Treatment Outcome
;
Young Adult
6.Clinical analysis of modiifed transcatheter closure of atrial septal defect in 100 cases PU
Tiezheng LI ; Wenhui WU ; Xiaoyong HUANG ; Xi GUO ; Guangrui LIU ; Peng LI ; Yuguo XUE ; Mingliang PENG ; Lianjun HUANG
Chinese Journal of Interventional Cardiology 2014;(6):353-356
Objective To summraize the safety and efifcacy of modiifed transcatheter closure of atrial septal defect. Methods From Dec. 2012 to Dec. 2013, 100 cases performed modiifed transcatheter closure of atrial septal defect in our center (72 were famale and 28 were male) with average age (37±16) years. The diagnosis was conifrmed by transthoracic echocardiography. All the atrial septal defect closures were completed in the modiifed way by direct delivery of the closure devices without the need of guidence wire. Results One hundred and one defects were identiifed in 100 patients, with 1 patient had 2 defects. The mean diameter of the defect was (20.3±6.6) mm. 100 devices were implanted successfully. Complete closure was revealed in all the patients after the procedure. One patient developed atrial ifbrillation during the procedure. No other serious complication occurred till the last follow-up. Conclusions The modiifed transcatheter closure of atrial septal defect is an effective procedure with high successful rate and low rate of complications.
7.Aortic remodeling after thoracic endovascular aortic repair with stent graft in acute type Stanford B aortic dissection
Yongshan GAO ; Xi GUO ; Wenhui WU ; Guangrui LIU ; Xiaofeng HAN ; Lianjun HUANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2017;33(12):725-728
Objective To explore the aortic remodeling after thoracic endovascular aortic repair for acute type stanford B aortic dissection. Methods Retrospective analysis the clinical data of 51 patients who diagnosed with acute type B aortic dis-section and received TEVAR between September 2015 and August 2016. The maximal diameters of false and true lumen were measured directly at the level of primary tear entry, the level of the bronchial bifurcation,and the level of the celiac trunk and the the lower edge of left renal artery,changes in diameter were evaluated between the preoperative and postoperative CT scan. Results The marked change in the true lumen dilatation and false lumen regression trend at the level of primary tear entry after thoracic endovascular repair(1 month vs 1 year, P<0. 05), while the changes of its diameter above level were not obvious af-ter thoracic endovascular repair(3 months vs 6 months, P>0. 05). the true lumen dilatation and false lumen regression trend at the level of the bronchial bifurcation along with time. The true lumen dilatation is a process of slow change at the level of the celiac trunk and the lower edge of left renal artery after TEVAR, and the false lumen changed not obviously. Conclusion En-dografting is effective for acute type B aortic dissection which can promote positive descending aortic remodeling changes,but it has no significant effect on abdominal aortic remodeling.
8. Magnetic tracer technique in laparoscopic localization for gastrointestinal lesions
Mudan REN ; Feng MA ; Xuejun SUN ; Xiaopeng YAN ; Wei ZHAO ; Jianbao ZHENG ; Wenhui MA ; Xinlan LU ; Shuixiang HE ; Guifang LU
Chinese Journal of Digestive Endoscopy 2019;36(11):821-825
Objective:
To evaluate the feasibility and safety of magnetic tracer technique for preoperative endoscopic marking in laparoscopic surgery.
Methods:
In the preliminary study, a total of 8 patients with gastric (n=3) or colorectal (n=5) tumors underwent endoscopic magnetic marking before laparoscopic surgery from April to June in 2019. First, a magnet was attached to the lesion by 2 titanium clips under the endoscope. Second, during the subsequent laparoscopic operations, the other magnet was sent to the vicinity of the lesion through the laparoscopic tunnel. The magnet in the abdominal cavity was quickly attracted to the one in the gastrointestinal tract to successfully locate the lesions. Data of preoperative marking and operations of 8 patients were reviewed.
Results:
All 8 lesions were marked successfully, rapid and accurate intraoperative positioning was achieved. The mean time of endoscopic marking was 5.75±2.45 minutes, and the mean time of intraoperative localization was 1.94±0.56 minutes. All patients underwent laparoscopic tumor resections with accurate localization. The mean proximal and distal resection margins of colorectal tumors were 105 mm and 74 mm respectively. No complications occurred.
Conclusion
Magnetic tracer technique for laparoscopic localization, simple, safe and accurate for gastrointestinal lesions, can be performed without additional equipment or endoscopic procedures involved.
9.Clinical significance of the ratio of serum copper to zinc in patients with inflammatory bowel disease
Ruixin XING ; Hongqian WANG ; Wenhui ZHANG ; Xiaohan MA ; Jing GUAN ; Xi CHEN
Chinese Journal of Digestion 2021;41(10):665-670
Objective:To explore the serum levels of copper and zinc and the application value of the ratio in assessing disease activity in patients with inflammatory bowel disease (IBD).Methods:From March 2019 to April 2020, 200 patients with IBD hospitalized at the Department of Gastroenterology of the First Affiliated Hospital of Anhui Medical University were selected by prospective random direct sampling method, including 100 patients with Crohn′s disease (CD) and 100 patients with ulcerative colitis (UC). The Crohn′s disease activity index (CDAI) and the modified Mayo score were used to evaluate the disease activity of CD patients and UC patients. In the same period 100 healthy individuals in the routine physical examination were selected as healthy control group. The serum levels of copper and zinc of the healthy control group, the CD group and the UC group were determined by atomic absorption spectrometry. The levels and the ratio of serum copper to zinc of three groups were compared. The ratio of serum copper to zinc of CD patients and UC patients with different disease activity were compared. The correlation between the ratio of serum copper to zinc and IBD activity indexes were analyzed, which included fecal calprotectin (FC), C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), CDAI and Mayo score. Receiver operating characteristic curve was drawn to analyze the value of the ratio of serum copper to zinc, CRP and ESR in predicting disease activity of patients with IBD. Independent sample t test, least significant difference- t test and Pearson correlation analysis were performed for statistical analysis. Results:The serum copper levels and the ratio of serum copper to zinc of the CD group and the UC group were both higher than that of the healthy control group, however the serum zinc levels were lower than that of the healthy control group ( (32.27±7.69) and (29.80±9.68) mol/L vs. (20.16±6.67) mol/L; 2.81±1.57 and 2.29±1.09 vs. 0.68±0.36; (14.64±7.11) and (15.65±8.17) mol/L vs. (34.29±16.40) mol/L), and the differences were statistically significant ( t=2.81, 5.87, 1.47, 7.21, 1.73 and 2.56, all P<0.05). Among CD patients, the the ratio of serum copper to zinc of patients at remission stage (29 cases), mild activity stage (23 cases), moderate activity stage (30 cases) and severe activity stage (18 cases) was 2.61±1.43, 2.75±1.35, 3.15±2.37 and 4.17±1.77, respectively, and the ratios of serum copper to zinc of patients at mild activity stage, moderate activity stage and severe activity stage were all higher than that of patients at the remission stage, and the differences were statistically significant ( t=3.41, 7.92 and 5.84, all P<0.05). There were statistically significant differences in the ratios of serum copper to zinc between patients at mild activity stage and moderate activity stage, severe activity stage, and between patients at moderate activity stage and severe activity stage ( t=5.82, 6.23 and 3.45, all P<0.05). Among UC patients, the ratio of serum copper to zinc of patients at remission stage (10 cases), mild activity stage (30 cases), moderate activity stage (45 cases) and severe activity stage (15 cases) was 1.52±0.44, 1.74±0.58, 2.38±0.83 and 3.80±1.19, respectively, the ratio of serum copper to zinc of patients at moderate activity stage was higher than that of patients at remission stage and mild activity stage, and the ratio of serum copper to zinc of patients at severe activity stage was higher than those of patients at remission stage, mild activity stage and moderate activity stage, and the differences were statistically significant ( t=7.92, 5.83, 3.21, 9.54 and 2.83, all P<0.05). There was no statistically significant difference in serum copper to zinc ratio between patients at remission and at mild activity stage ( P>0.05). The ratio of serum copper to zinc of CD patients was positively correlated with FC and CRP ( r=0.697 and 0.586, P=0.014 and 0.001), however was not correlated with ESR or CDAI score (both P>0.05). The ratio of serum copper to zinc of UC patients was positively correlated with FC, ESR and Mayo score ( r=0.488, 0.452 and 0.331, P=0.001, P<0.01 and P=0.041), however was not correlated with CRP ( P>0.05). The cut-off value of the ratio of serum copper to zinc, CRP and ESR for the diagnosis of CD activity was 1.76, 8 mg/L and 20 mm/1 h, respectively. Among them, ESR was the most effective in the diagnosis of CD activity with an area under the curve (AUC) value of 0.830, and to the sensitivity and specificity was 69.0% and 86.2%, respectively. The cut-off value of the ratio of serum copper to zinc, CRP and ESR for the diagnosis of UC activity was 1.63, 8 mg/L and 20 mm/1 h, respectively; among which the the ratio of serum copper to zinc had the highest efficacy in the diagnosis of UC activity, with an AUC value of 0.862, sensitivity and specificity of 73.0% and 90.9%, respectively. Conclusion:The the ratio of serum copper to zinc is correlated with the disease activity of IBD, which may become a new auxiliary indicator for the evaluation of disease activity.
10.Efficacy of personalized endovascular repair using two stent-grafts for patients with Stanford B aortic dissection.
Xiaoyong HUANG ; Lianjun HUANG ; Xi GUO ; Yuguo XUE ; Peng LI ; Wenhui WU ; Guangrui LIU ; Tiezheng LI ; Mingliang PENG ; Qinglong ZENG
Chinese Journal of Cardiology 2015;43(1):39-43
OBJECTIVETo observe the feasibility and clinical efficacy of thoracic endovascular aortic repair (TEVAR) for patients with Stanford B aortic dissection using personalized two stent-grafts implantation (TSI).
METHODSThis retrospective review included 56 patients who underwent TSI during TEVAR for Stanford B aortic dissection from Jan 2012 to May 2013 in Beijing Anzhen hospital. There were 8 patients in acute phase (within 2 weeks from onset of symptoms), 11 patients in chronic phase (greater than 2 months following initial dissection) and 37 patients in subacute phase (between 2 weeks and 2 months from onset of symptoms). Infrarenal aorta was involved in 34 patients (60.7%) and suprarenal aorta involved in 22 patients (39.3%), the mean aortic lesion length was (226 ± 13)mm. Thoracic and abdominal aortic angiography was performed during operation to measure aortic diameters of proximal and distal landing zone, and the distance between them. The proximal stent-grafts were implanted in distal aorta to the origin of left subclavian artery with oversize rate of 10%-15% according to proximal landing zone according to procedural guideline. Then the distal newly customized large tapered stent-grafts were sequentially deployed according to the diameters of both the distal end of proximal stent and distal landing zone (aortic true lumen), and overlapping length of the two stent-grafts was more than 30 mm. Patients were followed-up at 3 months, 6 months, and yearly thereafter post operation.
RESULTSTSI procedure was successful in all patients and 122 stent-grafts were implanted. The mean length of implanted stent-grafts was (197.6 ± 20.3)mm. The mean diameter taper span was (7.5 ± 1.8)mm with proximal oversize rate of (12.8 ± 3.4)% and distal oversize rate of (11.2 ± 4.1)%. The mean angle between the distal end of stent and aorta was (2.3 ± 1.3)°. The diameter of proximal and distal landing zone, and angle between the distal end of stent and aorta remained unchanged during follow up (mean: (10.0 ± 4.0) months). The total thrombosis rate of the false lumen was 98.2% (55/56), thrombosis rate of stent segment was 82.1% (46/56) . Stent-related complications were observed in 2 patients (3.6%) , including acute spinal cord ischemia due to paraplegia (n = 1) and malposition of distal stent (n = 1).
CONCLUSIONSEncouraging short-term outcomes are obtained from current personalized two stent-grafts implantation strategy for patients with Stanford B aortic dissection. Further prospective clinical studies are warranted to evaluate the long-term efficacy of this procedure.
Acute Disease ; Aneurysm, Dissecting ; Aorta ; Aortic Aneurysm ; Aortic Aneurysm, Thoracic ; therapy ; Aortography ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation ; Endovascular Procedures ; Humans ; Prospective Studies ; Retrospective Studies ; Stents ; Subclavian Artery ; Thrombosis ; Tomography, X-Ray Computed ; Treatment Outcome