1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report
Ying' ; ao ZHAO ; Yiming YAN ; Ziping LI ; Hang LI ; Fengwen ZHANG ; Fang FANG ; Guangzhi ZHAO ; Jing DONG ; Chuangshi WANG ; Jiande WANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1796-1799
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
7.Robotic Assisted Transcatheter Edge-to-edge Repair for Functional Mitral Regurgitation With Pure Trans-esophageal Echocardiography-guidance
Da ZHU ; Wenbin OUYANG ; Shouzheng WANG ; Zhiling LUO ; Xiangbin PAN
Chinese Circulation Journal 2024;39(6):606-609
We report the first in man experience of robotic assisted transcatheter edge-to-edge repair(TEER)with pure Trans-esophageal echocardiography-guidance.A 55y female was diagnosed with heart failure with 4+functional MR despite optimal medical treatment.TEER procedure was planned with robotic assistance.After guiding catheter,the robotic system was incorporated into the TEER device to replace manual operation.Under pure echo-guidance one clip was successfully placed in A2/P2 region with marked reduction of MR to 1+.Patient was discharged without complication.
8.A Case Report of Remote Robotic Transcatheter Edge-to-Edge Repair Under Pure Transesophageal Echocardiographic Guidance
Shouzheng WANG ; Da ZHU ; Shiguo LI ; Yaoxing LU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2024;39(8):816-818
We report the successful treatment of mitral regurgitation by remote robotic transcatheter edge-to-edge repair(TEER)under pure transesophageal echocardiographic guidance in a 70-year-old male patient with severe mitral regurgitation due to ischemic cardiomyopathy.The patient showed no significant improvement after coronary interventional treatment and guideline-directed medical therapy before TEER.Following a multidisciplinary discussion,a TEER procedure was indicated and performed.The procedure utilized robotic assistance guided by echocardiography,combined with 5G communication technology,to remotely operate the surgical robot in Shenzhen from Beijing.Postoperatively,the patient's mitral regurgitation was reduced to trace,symptoms were markedly improved,there were no severe complications,and the patient was discharged five days after the operation.The integration of pure echo-guided interventional technology with remote robotic operation holds significant importance for enhancing the capabilities in treating cardiovascular diseases at the primary hospitals.
9.Percutaneous Suture-mediated Patent Foramen Ovale Closure Guided Solely by Echocardiography:a Case Report
Yaoxing LU ; Shiguo LI ; Wenbin CHEN ; Wenbin OUYANG ; Guangzhi ZHAO ; Jianzhou GUO ; Xiangbin PAN
Chinese Circulation Journal 2024;39(10):1022-1024
This article reports a case using China's self-developed HaloStitch? system to complete a percutaneous suture-mediated patent foramen ovale closure under ultrasound guidance alone,achieving outstanding clinical outcomes.This innovative method represents a new approach to patent foramen ovale treatment and is an ideal surgical technique.
10.Cardiac Pacemaker Implantation Under Transthoracic Ultrasound Guidance
Daoliang ZHANG ; Jun LIU ; Yong JIANG ; Wenbin OUYANG ; Guangzhi ZHAO ; Xiangbin PAN
Chinese Circulation Journal 2024;39(10):1025-1027
This report describes a case of an elderly patient whose cardiac pacemaker lead had dislocated and whose battery had depleted.After evaluation,the patient required implantation of a leadless pacemaker.The procedure was successfully completed using solely transthoracic ultrasound guidance,marking the first leadless pacemaker implantation done with only ultrasound guidance,and achieved favorable clinical outcomes.

Result Analysis
Print
Save
E-mail