1.The latest development of analytical approaches for nuclear medicine-based functional neuroimaging
Weiyan ZHOU ; Chuantao ZUO ; Yihui GUAN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;36(3):270-275
The functional neuroimaging techniques might help to understand cerebral neuronal activities,synaptic transmission,fiber connections and other associated diseases at the molecular level.Since neuroimaging datasets are large,it is important to find some easy and efficient analytical approaches to facilirate the diagnosis and to reveal the pathogenesis for many neurological diseases.Functional imaging techniques are expected to be novel modalities for assessing diagnosis,treatment response and prognosis for neurological diseases.The latest development of analytical approaches for functional neuroimaging based on nuclear medicine is reviewed in this article.
2.Measurement of thyroid hormones, harmonization and standardization
Qinghui MENG ; Weiyan ZHOU ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2016;39(12):978-982
The incidence of thyroid dysfunction has increased year by year; the degree of public concern about thyroid disease also has been growing; the accuracy and comparability of results given by thyroid hormone assays from clinical laboratories face new challenges .This paper reviewed the clinical significance and measurements of thyroid hormones , also summarized the outcome of IFCC Working Group on Standardization of Thyroid Function Tests .It is expected to bring manufacturers′and clinical laboratories′attention to the importance of standardization/harmonization; and they could collaborate with each other .
3.Biological membrane for repair of different sizes of bone defects surrounding BLB implants
Weiyan MENG ; Yanmin ZHOU ; Shunli CHU ; Liming YANG ; Qing CAI
Chinese Journal of Tissue Engineering Research 2008;12(49):9771-9774
BACKGROUND:There is often space between implant and bone during immediate implantation.Whether biological membrane is needed to guide bone regeneration remains poorly understood.OBJECTIVE:To createdifferent sizes of space between femurand implantsindogs and to observe the effects of biological membrane on bone regeneration capacity of bone defects surrounding implants.DESIGN,TIME AND SETTING:A self-control animal experiment was performed at the Laboratory Animal Center,Norman Bethune College of Medicine,Jilin University and School of Stomatology,Jilin University between March and December 2005.MATERIALS:BLB hydroxyapatite-coated implant was provided by Beijing Leiden Biomaterial Co.,Ltd.,China;BME-10X collagen membrane was purchased from Fujian Better Biotechnology Co..Ltd.,China.METHODS:BLB implants were installed in the bilateral proximal femoral bone to create standard gradient bone defects with horizontal width 3 mm.vertical depth 5 mm,and horizontal lengths of 0,1,2,3,and 4 mm Bone defects on the left femur were sutured directly and those on the right femur were covered with biological membrane prior to suture.All animals were sacrificed at 3 months after surgery.Specimens containing implants were harvested to prepare tissue blocks for radiological observation.MAIN OUTCOME MEASURES:The quantity,color,and texture of newly formed bone surrounding implants were observed from the surface and profile levels.The implant-bone integration and new bone formation were also examined by soft X-ray photography.RESULTS:Grossobservation results revealed that when the horizontal length of bone defect was 3 mm or less,there was no significant differenee in bone density between the newly formed bone and the host bone no matter whether biological membrane existed or not;when the horizontal length of bone defect was 4 mm the bone density was better when biological membranes were used than not.Soft X-ray photography results revealed that when the horizontal length ofbone defect was 3 mm or less.no significant difference in bone density and bone trabecular morphology and orientating was found between newly formed bone and host bone no matter whether biological membrane was used or not;in the 4-mm-length bone defect areas.implants contacted with newly formed bone directly,but the calcified degree ofnewly formed bone was poor,bone trabecula was thin,and bone trabecular course was irregular,nevertheless,the calcified degree of newly formed bone was better under the condition of being with biological membrane than without biological membrane.CONCLUSION:Biological membrane exhibits strong capacity to promote the regeneration and repair of bone defect tissue with a horizontal length of 3 mm or less,and plays an important role in repatr of large sizes of bone detect
4.Effect of lornoxicam on the expression of plasma IL-6 and IL-10 in patients undergoing upper abdominal surgery
Zhihong ZHOU ; Jian LIU ; Ren GUAN ; Weiyan LI
Journal of Medical Postgraduates 2003;0(10):-
Objective: To investigate the analgesic effect and impact of lornoxicam on the expression of plasma IL-6 and IL-10 in patients undergoing upper abdominal surgery.Methods:Sixty patients undergoing upper abdominal surgery were randomly allocated into three groups,morphine group(M,n=20),postoperative lornoxicam group(L,n=20) and preemptive lornoxicam group(P,n=20).For group M the subjects received patient controlled intravenous analgesia(PCIA) with morphine(loading dose 0.05 mg/kg,bolus 1 mg,lockout time 10 min,background dose 0 mg) after the surgery.While in group L,8 mg lornoxiam was administered at the end of the surgery,then the same morphine PCIA scheme as in group M was used in combination with intermittent intravenous lornoxiam(8 mg per injection) at 12,24 and 36 h after the surgery.Except that the first 8 mg lornoxicam was injected 30 min before the operation,the analgesic paradigm of group P was similar to group L.The analgesic effect assessed by VAS at rest,the consumed dosage of morphine,and the adverse effects as nausea and vomiting,were recorded at 4,8,12,24 and 48 h.Furthermore,2 ml of the venous blood was drawn before the induction of anesthesia 2,6,12,and 24 h after the surgery to measure the levels of interleukin 6(IL-6) and interleukin 10(IL-10).Results: During the 48 h observation,the VAS at rest was not statistically significant in the three groups,but more morphine was consumed in group M than in group L and group P.There was no difference among the three groups in the incidence of such adverse effects as nausea or vomiting.The basic levels of IL-6 and IL-10 were too low to be measured.The concentrations of IL-10 and IL-6 reached the peak at 2 and 6 h after surgery respectively,and the level of IL-10 in group M was significantly lower than in groups L and P at 2 h.In contrast,the level of IL-6 in group M was significantly higher than in group L and group P at 6 h,and even higher than in group P at 12 h. Conclusion: Lornoxicam,especially when administered before upper abdominal operation,could significantly decrease the dose of morphine for postoperative analgesia and attenuate the inflammatory cytokine response after surgery.
5.A moderate dose of levobupivacaine in spinal anesthesia for caesarean section
Weiyan LI ; Hongjun LIU ; Jianjun YANG ; Qiuming ZHOU
Journal of Medical Postgraduates 2003;0(03):-
Objective: To investigate a moderate dose of levobupivacaine in spinal anesthesia for caesarean section.Methods: Eighty parturients undergoing caesarean section were randomly divided into 4 groups: GroupⅠ(0.75% levobupivacaine 1.00ml+10% glucose 1.00ml+cerebrospinal fluid 1.00ml),GroupⅡ(0.75% levobupivacaine 1.33ml+10% glucose 1.00ml+ cerebrospinal fluid 0.67ml),Group Ⅲ(0.75% levobupivacaine 1.67ml+10% glucose 1.00ml+ cerebrospinal fluid 0.33ml) and Group Ⅳ(0.75% levobupivacaine 2.00ml+10% glucose 1.00ml).The spinal puncture sites were all located at L_2,3.The onset time of sensation block,the highest plane of analgesia,the time to reach the highest plane of analgesia,the time of regression to the L_1 segment,the degree of motor block,VAS scores,the degree of muscle relaxation,the rate of hypotension incidents and neonatal Apgar scores were recorded. Results: There were no statistically significant differences in the onset time of sensation block,the time to reach the highest plane of analgesia and the highest plane of analgesia among the 4 groups.But the durations of regression to the L_1 segment were dramatically shorter in GroupⅠand Ⅱthan in Group Ⅲ and Ⅳ(P
6.Influence of different implant diameters on implant-bone-interface stress distributions in zygomatic implant denture
Shunli CHU ; Yanmin ZHOU ; Weiyan MENG ; Guiping YUE
Journal of Jilin University(Medicine Edition) 2006;0(04):-
Objective To study the influence of different implant diameters on the implant-bone-interface stress distributions in zygomatic implant denture and illustrate the correlation between implant diameter and long-dated success rate of zygomatic implant denture.Methods Three-dimensional finite element model for maxilla and zygoma was established biomechanically in this study by spiral CT technique and finite element software technique,and zygomatic implant was simulated into the model in the first-maxillary-molar region.Zygomatic-implant-denture load cases concerning different implant diameters(3.5,4.0 and 5.0 mm) were designed and loaded vertically,obliquely.The implant-bone-interface stress distributions were analyzed by 3-D finite element method.Results The model could be observed from any angle,and had good geometric similarity compared with CT image.Stress peak values among these load cases with different diameters were compared,the load case with 3.5 mm diameter appeared the largest stress peak value,the load case with 4.0 mm diameter appeared the larger stress peak value and the load case with 5.0 mm diameter appeared the least stress peak value.As the implant diamater increased(3.5 mm→4.0 mm→5.0 mm),the compressive and tensive stress peak values of implant-bone interface in the maxillary alveolar ridge and the zygomatic area near maxillary sinus roof decreased gradually,the stress of implant-bone interface in the maxillary alveolar ridge was significantly larger than that of implant-bone interface in the zygoma area and compressive stress peak value was larger than tensive stress peak value.Conclusion The implant-bone-interface stress distributions tend towards uniformity as the implant diameter increases.Select wider-diameter implant as possible as the residual bone permitted clinically.
7.Hippocampal neuronal apoptosis and nuclear factor κB expression in rats with acute necrotizing pancreatitis with brain injury
Weiyan YUAN ; Guoxiong ZHOU ; Hua HUANG ; Hailing XU ; Zhongwei HUANG
Chinese Journal of Pancreatology 2011;11(2):120-122
Objective To investigate the relationship between expression of nuclear factor kappa B p65 ( NF-κB p65) and hippocampal neuronal apoptosis in acute necrotizing pancreatitis (ANP) rats with brain injury. Methods Sixty-four SD rats were randomized into normal saline group (NS) and ANP group. The ANP rat model was induced by retrograde injection of 4% sodium taurocholate into the pancreaticobiliary duct of SD rats. Nissle stain was used to detect the brain injury. Neuronal apoptosis was determined by TUNEL.NF-κB p65 expression was detected by immunohistochemistry and RT-PCR. Results Hippocampal neuron was absent, karyopyknosis, unclear nucleolus and decreased Nissl bodies were found, the injuries was aggravated with time. The apoptosis index at the 3, 6 and 12 h in ANP group was 10.63 ±0.24, 21.02±0.25, 17.12±0.36, respectively, while they were 0.33±0.19,0.71±0.67, 0.45 ± 0. 33 in NS group, and the difference was statistically significant ( P < 0. 01 ). The expressions of NF-κB p65 mRNA were 0. 63 ± 0.05,1.05 ±0.06,0.92 ±0.05, which were significantly higher than those in the NS group (0.11 ±0.01,0.12±0.01,0.08±0.01,P<0.05).The chatge of expression of NF±κB p65 protein was consistent with that of NF-κB p65 mRNA. Conclusions The brain injury of ANP rats was highly correlated with neuronal apoptosis at the early and middle phase of ANP, and its mechanism may be related with NF-κB p65 activation.
8.Observation for clinical effects of glassfiber post with all-ceramic-crown for incisors restoration
Nianxiang BAO ; Liwen ZHOU ; Yurui HONG ; Weiyan LUO ; Guizhen ZENG
Chinese Journal of Practical Nursing 2010;26(20):28-29
Objective To investigate the clinical effect of glassfiber post with all-ceramic-crown for incisors restoration, providing some references for our clinical application. Methods 82 patients (100 teeth defect) in our department from October,2008 to October, 2009 were divided into group A and group B with 50 incisors in each. Glassfiber post with all - ceramic - crown was used in group A, and metal post with porcelain-fused-to-metal in group B. After one year follow-up, we observed the clinical effect. Results 49 cases were effective and 1 case failed in group A. 42 cases were effective and 8 cases failed in group B.There was statistically significant difference between the two groups. Conclusions Glassfiber post with all-ceramic-crown is better in convenient handling and good colour for incisors compared to metal post with porcelain-fused-to-metal.
9.The stereomicroscopy observation for bone-defect restoration around BLB implants
Weiyan MENG ; Yanmin ZHOU ; Yanqiu LI ; Shunli CHU ; Lei GUO
Journal of Practical Stomatology 2000;0(05):-
Objective:To observe the bone regeneration capacity of bone defects around BLB implants covered with or without membranes.Methods:Implants were installed into femoral bone of grown-up dogs.Near implants,3 mm horizontal width,5 mm vertical depth and 1,2,3,4 mm horizontal length(along the macroaxis of femoral bone) standard gradient bone defects were made.On one side,the incisions were directly sutured by lamination,and on the other side the incisions were sutured by lamination after using collagen membrane to cover on the defects.Three months after the operation the specimens were observed by stereomicroscopy.Results:In the groups with 1,2 and 3 mm defects,the defect areas had been filled completely with new bone which was mainly compact cortex.In the group with 4 mm defects,the defect areas were filled with new bone which was mainly trabecular bone.Bigger lacunes could be observed in the groups without membranes.Conclusion:If the defect is less than 3 mm,whether bioresorbable collagen membrane is used or not,osseointegration is well in the implant-bone interface.Improving bone regeneration should be done when the bone defect extension is bigger.
10.Detection of mutations of exons 5 and exons 8 of PTEN gene in oral squamous cell carcinoma
Weiyan CHEN ; Li GONG ; Tiejun ZHOU ; Xian′Gang YIN ;
Journal of Practical Stomatology 2001;0(01):-
Objective:To detect mutations of exons 5 and exons 8 of PTEN gene in oral squamous cell carcinoma(OSCC),and to explore the relationship between gene mutations and development of OSCC.Methods: Mutations of exons 5 and exons 8 of PTEN gene were detected by polymerase chain reaction-single strand conformation polymorphism(PCR-SSCP).Results: The whole sequences of exons 5 and exons 8 of PTEN gene of all cases of OSCC were expanded.There was no mutation in exons 5 and exons 8 of PTEN gene of all cases of OSCC.Conclusion: There is no mutation in exon 5 and exon 8 of PTEN gene in OSCC.This might show that there is no correlation between mutations in exon 5 and exon 8 of PTEN gene and the development of OSCC.