1.Spiral CT Atypical Appearances of Small Hepatocellular Carcinoma with Pathologic Correlation
Weipeng HUANG ; Jierong CHEN ; Jiansheng XU ; Jilin GE ; Lijun CHEN
Journal of Practical Radiology 2001;0(09):-
Objective To investigate the atypical appearances of small hepatocellular carcinoma(SHCC) with triple-phase spiral CT enhanced scan, and its correlation with the histopathology .Methods The atypical CT signs in triple-phase and histopathologic changes of SHCC confirmed pathologically in 30 cases (32 lesions) were analysed.Results 32 atypical lesions were found in 30 patients,of them,14 lesions were hypodense in hepatic arterial phase(HAP),portal venous phase(PVP) and delayed phase(DP).10 lesions enhanced markedly in the AP,while these lesions became isodense or slight hyperdense in the PVP and DP.8 lesions were enhanced as ring like or punctual shape in the AP,and constant enhancement in PVP and DP.Conclusion The atypical appearances are present in triple- phase spiral CT scan in SHCC,the pattern of blood supply and the base of histopathology are usually the cause of these findings .
2.Value of real-time three-dimensional echocardiography in patients with restrictive cardiomyopathy and constrictive pericardits
Cuizhen PAN ; Xianhong SHU ; Weipeng ZHAO ; Lili DONG ; Junbo GE
Chinese Journal of Ultrasonography 2011;20(3):189-192
Objective To investigate value of real-time three-dimensional echocardiography timingexcursion parametric index and 17 segment volume curves index in patients with restrictive cardiomyopathy and constrictive pericardits.MethodsSeventeen patients with restrictive cardiomyopathy (proven by biopsy) ,six patients with constrictive pericardits (proven by CT or surgical),twenty subjects with normal left ventricular(LV) function were examined by Philips iE33 with X3-1 probe.Results Parameter index of Tmsv 16-SD,Tmsv 12-SD Tmsv 6-SD,Tmsv 16-Dif,Tmsv 12-Dif,Tmsv 6-Dif,Tmsv 16-SD(%) ,Tmsv 12-SD(%),Tmsv 6-SD(%),Tmsv 16-Dif(%),Tmsv 12-Dif(%),Tmsv 6-Dif(%) was significantly higher in patients with restrictive cardiomyopathy than that in subjects with normal LV function(all P <0.05).Average and maximum value and minimum of excursion was significantly lower in patients with restrictive cardiomyopathy than that in subjects with normal LV function (all P <0.005).Whereas,compare with subjects with normal LV function,the parametric indexes of timing-excursion and 17 segment volume curves were not significantly difference in patients with constrictive pericardits(all P >0.05).Conclusions Realtime three-dimensional echocardiography can evaluate and diagnose fastly restrictive cardiomyopathy and constrictive pericardits.
3.The effects between Supreme laryngeal mask airway and endotracheal intubation on stress reaction of eld-erly hypertensive patients treated with knee arthroplasty
Haishan ZHANG ; Dalong WANG ; Zhenfang ZUO ; Weipeng GE ; Zhongwei WANG ; Guanrong ZHENG ; Ke LIU ; Shuai WANG
The Journal of Clinical Anesthesiology 2014;(6):577-580
Objective To investigate the effects of supreme laryngeal mask airway (SLMA) and endotracheal intubation on the elderly hypertensive patients treated with knee arthroplasty. Methods Forty cases of elderly hypertensive patients ASA Ⅰ-Ⅲ treated with knee arthroplasty in our hospital were selected and randomly divided into laryngeal mask airway group (group LMA)and endotracheal intubation (group TT),20 cases for each group.The same protocol for induction and maintenance of general anesthesia was used.After the patients entering,the changes of SpO2 and ECG were performed continuous noninvasive monitoring and SBP,DBP and HR were performed con-tinuous invasive monitoring.SBP,DBP and HR of two groups were recorded at different time points:before anesthesia induction (T0 ,based value),at intubation immediate (T1 ),5 mins after intubation (T2 )and 1 5 mins after intubation (T3 ).At the same time,the content of cortisol (Cor),atrial natri-uretic peptide (ANP)and the concentration of epinephrine (E)and norepinephrine (NE)were meas-ured at the corresponding time points above.Results Compared with T0 ,SBP and DBP at T1-T3 in group LMA were decreased(P <0.05 or P <0.01);SBP and DBP at T1 in group TT were increased while decreased at T2 ,T3 ,HR at T1 were increased(P < 0.05 or P < 0.01 ).Compared with group LMA,SBP and DBP at T1-T3 and HR at T1 ,T2 in group TT were increased (P <0.05 or P <0.01). Compared with T0 and group LMA,the content of E,NE and Cor at T1-T3 increased(P <0.05 or P <0.01).The level of ANP in both groups at T1-T3 were higher than those at T0 ,and group TT were higher than group LMA(P <0.01).Conclusion Compared to endotracheal intubation,SLAM can ef-fectively reduce the stress reaction of elderly hypertensive patients treated with general anesthesia in knee arthroplasty.
4.Individualized application of occluder in transcatheter closure of multi-fenestrated atrial septal defects
Lei ZHANG ; Daxin ZHOU ; Weipeng ZHAO ; Wenzhi PAN ; Xiaochun ZHANG ; Junbo GE
Chinese Journal of Interventional Cardiology 2017;25(3):138-143
Objective To evaluate the impact of individualized occluder application on efficacy and complications of transcatheter closure treatment for multi-feneatrated atrial septal defects (mfASD).Methods Seventy six patients with mfASD who were hospitalized at Fudan University Zhongshan Hospital from July 2006 to July 2015 were retrospectively enrolled.Clinical and follow-up data were collected and analyzed.Results Among the 76 patients including 18 males and 58 females,transcatheter closure was successfully performed in 73 patients (96.1%).The morphological features of ASD included: 60 cases (78.9%) with two defects and 16 cases (21.1%) with cribriform defects, 3 cases (3.9%) combined with patent foramen ovale (PFO),13 cases (17.1%) with atrial septal aneurysm (ASA).Dual occluders were used for closure in 26 patients (35.6%),while single occluder was implanted in 47 patients (64.4%).In single-occluder group,measuring balloon was used to assist occlusion in 7 patients (14.9%).3 patients versus 11 patients required the small-waist-big-edge occluders in the dual-occluder group and the single-occluder group respectively (11.5% vs.23.4%, P=0.352).The complication rate in the dual-occluders group was higher than that in the single-occluder group (19.2% vs.4.3%, P=0.037),while the incidence of residual shunt showed no significant difference between these two groups (11.5% vs.10.6%, P=0.906).Conclusions The occluder for transcatheter closure of multiple atrial septal defects needs to be individually chosen according to the morphological characters.Transcatheter closure of mfASD using two devices is feasible,safe and effective for selected patients.
5.The application value of real-time two-dimensional and three-dimensional transesophageal echocardiography in transcatheter aortic valve implantation
Cuizhen, PAN ; Xianhong, SHU ; Daxin, ZHOU ; Wenzhi, PAN ; Weipeng, ZHAO ; Dehong, KONG ; Hong, LUO ; Junbo, GE
Chinese Journal of Medical Ultrasound (Electronic Edition) 2016;13(12):887-892
Objective To investigate the value of two-dimensional and three-dimensional transesophageal echocardiography (3DTEE) in transcatheter aortic valve implantation (TAVI). Methods Eleven patients with severe aortic stenosis and one patient with moderate to severe prosthetic valve regurgitation underwent TAVI in Zhongshan Hospital of Fudan University from May 2010 to December 2015. All patients received two-dimensional and three-dimensional transthoracic and transesophageal echocardiographic examination before surgery, during and after surgery.Results Procedural success was achieved in eleven patients, but one patient died in pericardial tamponade and aortic dissection three days after TAVI. The maximum and minimum diameter of aortic annule, the area of aortic annule and aortic valve were measured by multidetector computed tomography (MDCT) and 3DTEE before surgery. All parameters had strong correlations between MDCT and 3DTEE (r=0.98,P<0.01 for maximum diameter;r=0.97,P<0.01 for minimum diameter;r=0.97,P<0.01 for the area of aortic annule;r=0.99, P<0.01 for the area of aortic valve). There were good correlations for the area of aortic valve among MDCT, 3DTEE and equation of continuity (allr=0.99,P<0.01).ConclusionTwo-dimensional and three dimensional transesophageal echocardiography can quantify the size of aortic annular and comprehensively evaluate the anatomical structure of aorta rapidly and accurately, which can be used in guiding TAVI and monitoring its complications in real time.
6.Clinic features and echocardiographic evaluation of patients with idopathic submitral left ventricular aneurysm
Qing LI ; Cuizhen PAN ; Xianhong SHU ; Weipeng ZHAO ; Wenjun DING ; Junbo GE
Chinese Journal of Ultrasonography 2014;23(6):480-483
Objective To study cinical features of patients with idopathic submitral left ventricular aneurysm(ISLVA) and evaluate their global and segmental systolic function as well as diastolic function through echocardiography.Methods Clinical features of eight patients with ISLVA were analysed retrospectively.Standard 2-dimentional and real-time 3-dimentional echocardiography were performed in all the eight cases and other twenty subjects with normal left ventricular(LV) function (defined as control group).Results Two patients were diagnosed as ISLVA due to ventricular arrythmia and the other six case sowing to congestive heart failure.Coronary angiography was normal in all patients.Apical systolic murmur was audible in 6 cases.Four patients received mitral valve surgical repair,one underwent aneurysm resection and radiofrequency ablation,implantable cardioverter defibrillator was implanted in one case,one was only treated by medication.One case died.Patients with ISLVA demonstrated significanly larger left atrium(LA) and LV diameter (both end-diastolic and end systolic),thinner LV posterior wall,and lower LV ejection fraction (LVEF) than controls (P <0.05).Indexes of the LV 17 segments time-volume curves including the time to minimal systolic volume(Tmsv) 16-SD,Tmsv 12 SD,Tmsv 6-SD,Tmsv 16-Dif,Tmsv 12-Dif,Tmsv 6-Dif,Tmsv 16-SD%,Tmsv 12-SD%,Tmsv 6-SD%,Tmsv 16-Dif%,Tmsv 12-Dif%,Tmsv 6-Dif% were significantly higher in patients with ISLVA than those in controls(all P <0.05).All patients with ISLVA showed mitral regurgitation and decreased LV diastolic function in varying degrees,five patients accompanied by elevated LA pressure.Conclusions Clinical features of patients with ISLVA are nonspecific.Echocardiography can evaluate systematically their functional and structural abnormalities.
7.Study of left ventricular systolic synchrony in patients with left ventricular noncompaction using real-time three-dimensional echocardiography
Cuizhen PAN ; Xianhong SHU ; Weipeng ZHAO ; Dehong KONG ; Haohua YAO ; Junbo GE
Chinese Journal of Ultrasonography 2011;20(2):108-111
Objective To investigate the value of real-time three-dimensional echocardiography(RT-3DE) timing-excursion parametric index and 17 segment time-volume curves index in patients with leftventricular noncompaction(LVNC). Methods Ten patients with LVNC (proven by MRI) ,twenty subjects with normal LV function were examined by Philips iE33 with X3-1 probe. Results Parameter index (including Tmsv 16-SD,Tmsv 12-SD,Tmsv 6-SD,Tmsv 16-Dif,Tmsv 12-Dif,Tmsv 6-Dif,Tmsv 16-SD%,Tmsv 12-SD%, Tmsv 6-SD%, Tmsv 16-Dif%, Tmsv 12-Dif%, Tmsv 6-Dif%) of 17 segment time to minimal systolic volume was significantly higher in patients with LVNC than that in subjects with normal LV function( all P<0.05). Average and minimum value of excursion was significantly lower in patients with LVNC than that in subjects with normal LV function ( P<0.05). Conclusions RT-3DE with timeexcursion parameters and 17 segment of time- volume curve parameters can rapidly and accurately evaluate left ventricular systolic synchrony in patients with LVNC.
8.Assessment of left ventricular myocardiac mechanics after transcatheter aortic valve implantation by speckle tracking imaging
Xiaoguo CHEN ; Xianhong SHU ; Cuizhen PAN ; Weipeng ZHAO ; Dehong KONG ; Daxin ZHOU ; Wenzhi PAN ; Hong LUO ; Junbo GE
Chinese Journal of Ultrasonography 2017;26(4):277-281
Objective To evaluate the left ventricle systolic function in patients with aortic stenosis (AS) underwent transcatheter aortic valve implantation(TAVI) by speckle tracking imaging and to observe the indicators in bicuspid aortic valves(BAV) and tricuspid aortic valves(TAV) groups.Methods Twenty nine patients with AS were enrolled,all of them underwent TAVI successfully.The regular echocardiography and 3D full-volume images were acquired on before and 3 days,1 month after TAVI.Longitudinal strain,circumferential strain,and three-dimensional left ventricle ejection fraction(3D-LVEF) were analyzed using Qlab software.Results Compared with the baseline,aortic valve blood flow velocity (AV),maximum aortic valve pressure gradient (AVPG-max),mean aortic valve pressure gradient (AVPG-mean),aortic valve area(AVA) after TAVI were improved significantly.Global longitudinal strain(GLS) had a improvement on 3 days after TAVI(all P <0.001),and further increased during 1 month after TAVI (all P <0.001).Global circumferential strain(GCS) were increased during 1 month after TAVI(all P < 0.001).The 3D-LVEF after 1 month were improved significantly(all P <0.001).The BAV patients and TAV patients had similar changes in all of indicators observed.Conclusions The left ventricle systolic function has early improvement after TAVI,and further recovery during follow-up.The BAV patients can obtain a benefit from TAVI equally to the TAV patients.
9.Effect of doxepin on expression of p38MAPK in spinal cord of rats with neuropathic pain
Yunchao CHU ; Jingping LIU ; Weipeng GE ; Meiqing DU ; Guanrong ZHENG ; Lei CHE ; Kechang HUANG ; Zhongwei WANG
Chinese Journal of Anesthesiology 2018;38(12):1467-1470
Objective To evaluate the effect of doxepin on the expression of p38 mitogen-activated protein kinase (p38 MAPK) in the spinal cord of rats with neuropathic pain (NP).Methods Sixty clean-grade male Wistar rats in which intrathecal catheters were successfully implanted,weighing 200-250 g,were divided into 3 groups (n =20 each) by a random number table method:sham operation group (S group),NP group and doxepin group (D group).NP was induced by chronic constriction injury (CCI) to sciatic nerve.Doxepin 20 mmol/L (10 μl) was intrathecally injected at 3,7,14 and 21 days after CCI (T1-4) in group D.The mechanical paw withdrawal threshold (MWT) and thermal paw withdrawal latency (TWL) were measured at 1 day before CCI (T0) and at T1-4.The rats were sacrificed after measurement of pain threshold at T4,and L4-6 segments of the spinal cord were removed for determination of the expression of p38MAPK protein by Western blot.Results Compared with S group,MWT was significantly decreased and TWL was shortened at T2-4,and the expression of p38MAPK protein was up-regulated in NP and D groups (P<0.05).Compared with NP group,MWT was significantly increased and TWL was prolonged at T2-4,and the expression of p38MAPK protein was down-regulated in D group (P<0.05).Conclusion The mechanism by which doxepin mitigates NP is related to down-regulating p38MAPK expression in the spinal cord of rats.
10.CTCs Detection and Whole-exome Sequencing Might Be Used to Differentiate Benign and Malignant Pulmonary Nodules.
Changdan XU ; Xiaohong XU ; Weipeng SHAO ; Hongliang SUN ; Xiaohong LIU ; Hongxiang FENG ; Xianbo ZUO ; Jingyang GAO ; Guohui WANG ; Xiongtao YANG ; Runchuan GU ; Shutong GE ; Shijie WANG ; Liwei GAO ; Guangying ZHU
Chinese Journal of Lung Cancer 2023;26(6):449-460
BACKGROUND:
Low-density computed tomography (LDCT) improved early lung cancer diagnosis but introduces an excess of false-positive pulmonary nodules data. Hence, accurate diagnosis of early-stage lung cancer remains challenging. The purpose of the study was to assess the feasibility of using circulating tumour cells (CTCs) to differentiate malignant from benign pulmonary nodules.
METHODS:
122 patients with suspected malignant pulmonary nodules detected on chest CT in preparation for surgery were prospectively recruited. Peripheral blood samples were collected before surgery, and CTCs were identified upon isolation by size of epithelial tumour cells and morphological analysis. Laser capture microdissection, MALBAC amplification, and whole-exome sequencing were performed on 8 samples. The diagnostic efficacy of CTCs counting, and the genomic variation profile of benign and malignant CTCs samples were analysed.
RESULTS:
Using 2.5 cells/5 mL as the cut-off value, the area under the receiver operating characteristic curve was of 0.651 (95% confidence interval: 0.538-0.764), with a sensitivity and specificity of 0.526 and 0.800, respectively, and positive and negative predictive values of 91.1% and 30.3%, respectively. Distinct sequence variations differences in DNA damage repair-related and driver genes were observed in benign and malignant samples. TP53 mutations were identified in CTCs of four malignant cases; in particular, g.7578115T>C, g.7578645C>T, and g.7579472G>C were exclusively detected in all four malignant samples.
CONCLUSIONS
CTCs play an ancillary role in the diagnosis of pulmonary nodules. TP53 mutations in CTCs might be used to identify benign and malignant pulmonary nodules.
Humans
;
Lung Neoplasms
;
Exome Sequencing
;
Multiple Pulmonary Nodules
;
Carcinoma
;
DNA Repair