1.Study of the agile supply chain management on high-value consumables used in surgical operations
Huajuan MAO ; Sanyong JIN ; Weihui DAI ; Xiaohua HU
Chinese Journal of Hospital Administration 2014;30(6):466-469
By means of a demand characteristic analysis of high-value consumables in surgical operations,this article established the agile supply chain model of those consumables,and studied its management model as well as the running mechanism based on a series of advanced information technologies,such as case knowledge base,virtual storage,dynamic monitoring,etc.With such a system in place,the hospital realized on-demand and zero-inventory management of high-value consumables to satisfy the dynamic demand for surgical operations.
2.Development and application of a multifunctional impactor based on animal experiments
Hailin WANG ; Heda XIAO ; Sheng ZHANG ; Zongxing JIANG ; Weihui LIU ; Lijun TANG ; Ruiwu DAI
Chinese Journal of Tissue Engineering Research 2017;21(20):3196-3201
BACKGROUND: A few devices have been reported to be used for studies on trauma, but these devices are unavailable for establishing the animal models of trauma because of their limited application range. OBJECTIVE: To develop a multifunctional impact system and evaluate its application effect, thus paying ways for establishing the animal models of trauma and basic experiments.METHODS: The multifunctional impact system was designed based on the theory of energy storage device, simple multifunctional impact device and impact parameter measuring equipment, and its effectiveness and stability were detected. The rat chest and different visceral organs were subjected to the closed impact experiment using a 5 cm2 impact at the predetermined parameter of 200, 300, 400, 500 kPa, respectively. Afterwards, the rats were sacrificed for morphological observation.RESULTS AND CONCLUSION: The multifunctional impactor was successfully developed, of which the maximum impact stress could be adjusted from 0 to 200 kg and compressive and extrusion stress also could be continuously adjusted from 0 to 100 kg. The experimental results showed that the impactor made certain damage to the rat lung, liver and spleen suggesting its favorable effectiveness (P < 0.05) and repeatability (P > 0.05). These findings suggest that the impactor is easy to operate in various ways and holds good effectiveness and stability, and its impact parameters can be detected in real time. Therefore, the impactor is suitable for both establishing the animal model of trauma and basic experiments.
3.Changes in corneal epithelial thickness and optical density and their correlation after smart pulse technology-assisted transepithelial photorefractive keratectomy
Shiyang NIU ; Hua YANG ; Yan LI ; Zhiqiang DAI ; Xinmin LI ; Yulan ZHOU ; Ouyang ZHANG ; Baojun WANG
International Eye Science 2024;24(8):1308-1313
AIM: To evaluate the changes in corneal epithelial thickness(CET)and corneal optical density(CD)after smart pulse technology(SPT)-assisted transepithelial photorefractive keratectomy(TPRK)and analyze their correlation.METHODS: The prospective study included 60 patients(120 eyes)with myopia and myopic astigmatism who underwent SPT-TPRK in the ophthalmology department at the First Affiliated Hospital of Xinxiang Medical University between February and August 2023. Changes in CET and CD were evaluated preoperatively and at 1 wk, 1 and 3 mo postoperatively.RESULTS: A total of 14 cases(28 eyes)were lost to follow-up, and 3 patients(6 eyes)with postoperative haze were excluded from this study, resulting in a final inclusion of 43 patients(86 eyes). At 1 wk after SPT-TPRK, CET had statistically significantly thickened compared to preoperative levels(P<0.05), particularly in the CET at 0-2 mm central corneal area(P<0.05). At 1 mo after SPT-TPRK, the CET at 0-2 mm area had statistically significantly decreased(P<0.05). At 3 mo after SPT-TPRK, the CET at 0-2 mm had essentially reached preoperative levels. Postoperative CD values increased, with a positive correlation between CET in the 0-2 mm area and CD in the whole 0-2 mm area(r=0.256, P<0.05), and a positive correlation between CET in the 2-5 mm area and CD in the anterior 2-6 mm area(r=0.319, P<0.05).CONCLUSION: Corneal epithelial remodeling takes 3 mo in areas within 2 mm of the central cornea; areas with thinner CET have faster postoperative corneal epithelial remodeling and greater thickening in the early postoperative period; CD increases in the early postoperative period compared to the preoperative value, and in some areas, there is a positive correlation between CET and CD value.