1.Anterior reconstruction plate fixation for unstable posterior pelvic ring injuries
Jiannong JIANG ; Yong WANG ; Leiyan ZHANG ; Sichun HAO ; Weichun MENG ; Haiping JIANG ; Jiangang ZHOU ; Jun TAN ; Zhenhuan JIANG
Chinese Journal of Trauma 2012;28(8):730-735
Objective To discuss the surgical indications,relative merits and clinical outcomes of anterior reconstruction plate fixation for treating unstable posterior pelvic ring injuries.MethodsA retrospective study was done on clinical data of 36 patients with unstable posterior pelvic ring injuries treated with anterior reconstruction plate fixation from August 2004 to July 2010 and followed up for minimum one year.There were 25 males and 11 females,at mean age of 35.8 years ( range,13-62 years).There were two patients with anterior dislocation of the sacroiliac joint and 34 with posterior dislocation.According to Tile classification,there were four patients with type B fractures ( B1:3,B2:1 ) and 32 with type C fractures (C1-1:17,C1-2:12,C2:2,C3:1 ).Results All patients were followed up for average 2.3 years ( range,1-6 years).Fat liquefaction and superficial infection were founded in two patients who were cured by dressing change and frequent but low-dose blood transfusion.Eight patients were subjected to iatrogenic lateral femoral cutaneous nerve injury.Meanwhile,five of them was recovered after treatment with neurotrophic drugs,but there were still three patients leaving lateral thigh numbness.One patient had L5 nerve root injury due to pull force,and was recovered after three months of neurotrophic drug therapy.According to Matta and Tometta criteria,the reduction results were excellent in 23 patients,good in 11 and fair in four,with excellence rate of 94%.No reduction loss or implant failure occurred.According to Majeed scoring system,the clinical outcomes were excellent in 17 patients,good in 14,fair in four and poor in one,with excellence rate of 86%.Of the seven patients pre-operatively associated with sacral plexusinjury,three obtained full recovery,two got partial recovery and two were free from recovery.Conclusion The anterior reconstruction plate fixation takes advantages of wide surgical indications,simple exposure,low infection rate,satisfactory reduction and solid fixation and may be a main treatment method for unstable posterior pelvic ring injuries.
2.Clinical Value of Echocardiography on Aortic Valvuloplasty in Low-age Pediatric Patients With Congenital Aortic Valve Stenosis
Nan XUN ; Hongju ZHANG ; Xin SUN ; Weichun WU ; Hong MENG ; Kunjing PANG ; Zhenhui ZHU ; Hao WANG ; Shoujun LI ; Jun YAN
Chinese Circulation Journal 2015;(9):875-878
Objective: To evaluate the clinical value of echocardiography in aortic valvuloplasty (AVP) in the low-age pediatric patients with congenital aortic valve stenosis. Methods: We retrospectively studied 39 low-age (at median of 23 months) patients with congenital aortic valve stenosis who received aortic valve repair in our hospital for their echocardiography information, and statistically analyzed the main indicator changes by 4 time points as pre-operation and 1 week, 1-3 months, 6-12 months after the operation respectively. Results: In our study, the bicuspid to tricuspid valve ratio was approximately at 5.5/1 and 2 patients died during peri-operative period. Compared with pre-operative time point, Doppler aortic valve peak velocity (Vmax ) and the mean aortic transvalvular pressure gradient (MPG) were reduced accordingly, for Vmax: (4.30 ± 0.73) m/s vs (2.65 ± 0.78) m/s, (2.93 ± 0.63) m/s, (3.01 ± 0.83) m/s,P<0.01, for MPG: (45.78 ± 15.19) mmHg vs (18.24 ± 10.08) mmHg, (21.01 ± 10.08) mmHg, (22.31 ± 13.41) mmHg. Compared with pre-operative time point, left ventricular ejection fractions (LVEF) were similar in 3 post-operative time points. Compared with 1 week post operative time point, left ventricular end-diastolic anteroposterior diameter (LVEDD) was increased at 6-12 months post-operative time point, the relative wall thickness (RWT) was decreased, bothP<0.05, and aorta valve regurgitation (AR) was increasedP<0.01. Pearson correlation analysis showed that aortic annulus (AA) inner diameter was positively related to LVEDD (r= 0.648,P<0.01), negatively related to Vmax (r= -0.205,P<0.05) and RWT was positively related to Vmax (r= 0.196,P<0.05). There were 6 patients with pre-operatively decreased LVEF, 1 of them died and the rest 5 with elevated LVEF at 6-12 months post-operative period,P<0.05. Conclusion: Echocardiograghy could be used as the ifrst choice of imaging method for diagnosing congenital aortic valve stenosis, it has the important role for in-operative monitoring and post-operative evaluation of AVP in relevant patients.