1.Influence of Recipe Wenzhongxiaotan on Correlation Factor to S180 Bearing Cancer Mouse Interfered by Cold Pathogenic Factor
Haizhen DANG ; Pinkang WEI ; Xingjun ZHUANG
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(03):-
Objective To discuss the influence of Recipe Wenzhongxiaotan to S180 bearing cancer mouse interfered by cold pathogenic factor and study correlation factor index. Methods To treat S180 bearing cancer mouse by interfere in ice water with Recipe Wenzhongxiaotan, with the control of Recipe Xiaotansanjie group and chemotherapy group, the change of morphology and rectal temperature in mouse, growth velocity and volume in tumor after treatment with Recipe Wenzhongxiaotan were observed, and TXB2 in plasma of mouse was detected by RIA. Results It showed late and short in chilly morphology and rectal temperature amplitude small than other groups in Recipe Wenzhongxiaotan group. The rate to restrain tumor growth was 86.69%, 75.29%, 87.55% in Recipe Wenzhongxiaotan group, Recipe Xiaotansanjie group and chemotherapy group (FT-207), respectively. TXB2 was near in Recipe Xiaotansanjie group and chemotherapy group and the difference was significant compared cold model group (P 0.05) in Recipe Wenzhongxiaotan. Conclusions It may be restrain tumor growth which S180 tumor-bearing mice interfered by cold pathogenic factor and degrade TXB2 in Recipe Wenzhongxiaotan, the rate to restrain tumor growth was near to FT-207 and Recipe Xiaotansanjie.
3.Comparison of the ligustilide content in SFE-CO_2 extract of Siwu Decoction and its ingredient herb
Yuhua DANG ; Yingqin WEI ; Rong RONG ; Jiurong YUAN
Chinese Traditional Patent Medicine 1992;0(09):-
AIM: To compare the ligustilide content in Siwu Decoction and its ingredient herb. METHODS: To extract with SFE-CO 2 and to determine ligustilide with HPLC. RESULTS: Of the content of ligustilide, the highest in single herb, next in the mixture of Angelicae Sinensis Radix and Lignstic Rhizoma, the lowest in Siwu Decoction. CONCLUSION: When Angelicane Sinensis Radix and Lignstic Rhizoma were in compound preparation, the content of ligustilide became lower obviously.
6.Etiological analysis of infection after eye surgery and the investigation of drug sensitivity
Jian, WANG ; Pei-tao, YU ; Wei-hua, DANG ; Rui, WEN
Chinese Journal of Experimental Ophthalmology 2013;(5):421-423
Background Clinical researches showed that antimicrobial-resistance of bacterium is gradually serious.It is very important to master pathogen distribution and antimicrobial susceptibility after eye surgery.Objective This study was to investigate the distribution and drug sensitivity of pathogenic bacteria from ocular operative infection in 3-year duration to provide a reference for reasonable selection of antibiotics.Methods Sixtyfive positive specimens were obtained from 65 patients due to postoperative infection in Department of Ophthalmology of Shenzhou Hospital and Shengjing Hospital from 2009 January through 2011 December.The pathogenic bacteria were isolated and then the drug sensitivity test of conventional antibiotics was performed.Results Among the 65 ophthalmic specimens,35 strains of Gram-positive bacteria were isolated with the constituent ratio 53.8%,and 15 strains of Gram-negative bacteria accounted for 23.1%.Fungus was found in 15 cases with the constituent ratio 23.1%.Staphylococcus epidermidis accounted for 42.9% in Gram-positive bacteria,and Pseudomonas aeruginosa accounted for 33.3% in Gram-negative bacteria.Aspergillus was the main component of fungus,which accounted for 60.0% of the proportion 3 strains of methicillin-resistant Staphylococcus aureus (MRSA) in 8 strains of Staphylococcus aureus,but no vancomycin-resistant Enterococcus (VRE) and vancomycin-resistant Staphylococcus (VRS) were seen.The in vitro drug sensitivity test showed that the main Gram-positive bacteria,Staphylococcus epidermidis and Staphylococcus aureus,were sensitive to linezolid,vancomycin,levofloxacin and ciprofloxacin with the sensitive rates >50.0%,and these bacteria were lowly sensitive to penicillin and erythromycin with the sensitive rates ≤30.0%.Pseudomonas aeruginosa appeared to be the main Gram-negative bacteria,showing a sensitive rate ≥ 80.0% to tobramycin,amikacin,ceftazidime,cefepime,cefoperazone/sulbactam,piperacillin/tazobactam,imipenem and meropenem.Conclusions Staphylococcus epidermidis,Staphylococcus aureus,Pseudomonas aeruginosa and Aspergillus are primary pathogens in ocular infection after operation.Antibiotics such as penicillin,erythromycin,levofloxacin,cefotaxime seem to be relatively high resistant to eye infection.To choose sensitive antibiotics timely and reasonably is a key to the prevention and control of ocular infection after operation.
7.Recurrent pulmonary infection, offline difficulties and airway abnormalities
Jun LI ; Dongsheng ZENG ; Wei DANG ; Chen MENG
Chinese Pediatric Emergency Medicine 2011;18(2):126-128,后插一
Objective To discuss the relationship between pulmonary infection, offline difficulties and airway abnormalities and to discuss the type of airway abnormalities. Methods The clinical data of 43 patients of severe pneumonia with inspection of electronic fibro-bronchoscope in PICU from Feb 2008 to May 2010 were retrospectively analyzed. Results In the 43 cases,24 cases existel different degrees of airway abnormalities, most of airway cartilage softening,in 15 cases; laryngeal dysplasia in 3 cases; absence of the right bronchus and right lung in 1 case. Conclusion Many children may exist airway abnormalities,if they have such performance as the clinical manifestations of recurrent wheezing after birth, refractory respiratory infection or difficulties in clinical offline, the increase of PCO2 though the effective suction, paroxysmal cyanosis and excluded with heart disease. Those children should undergo inspection with electronic fibro-bronchoscope to confirm the diagnosis as early as possible.
8.Cervical stability changes following metal rubber cervical disc replacement
Chuanyi BAI ; Wenbo WEI ; Xiaoqian DANG ; Kunzheng WANG
Chinese Journal of Tissue Engineering Research 2015;19(16):2467-2472
BACKGROUND:Previous studies designed and made titanium metal rubber cervical disc prosthesis, and performed feasible studies on its effect on movement and stress distribution by replicating intervertebral discs. OBJECTIVE:To further observe the changes in the stability of goat cervical vertebra after metal rubber cervical disc replacement. METHODS:Nine goats were randomly divided into experimental group (n=6) and normal control group (n=3). Goats in the experimental group received metal rubber cervical disc replacement at C4/5segment. Goats in the normal control group did not receive any treatment. Radiographic data at anteroposterior and lateral position, hyperextension and excessive flexion were taken to measure intervertebral height, range of motion and intervertebral angle at C4/5 segment before operation, immediately, 4, 8, 12 weeks after operation. Subsequently, slicing and embedding of hard tissue at surgical segment, picric acid-acid fuchsin staining and scanning electron microscopy were conducted.RESULTS AND CONCLUSION:No significant difference in the intervertebral height and spinal range of motion at C4/5 segment at different time points was detected between postoperative results in the experimental group and preoperative results in the experimental group, normal control group. The intervertebral height at C4/5 segment was higher immediately, 4 and 8 weeks after surgery than preoperative result in the experimental group (P < 0.05). No significant difference in intervertebral angle at C4/5 segment was detectable between 4, 8 and 12 weeks postoperatively in the experimental group and normal control group (P < 0.05). At 4 weeks after surgery, bone did not contact with the edge of the prosthesis in the experimental group. At 8 weeks, the gap between bone and the prosthesis became smal, and some new bone attached to the edge of the prosthesis. At 12 weeks, a few osteoblasts were observed on the surface of the prosthesis. New osteogenic tissue grew into the prosthesis. Results suggested that metal rubber cervical disc replacement in the intervertebral space could maintain intervertebral height and range of motion in a short period, and tightly bind to the vertebral body.
9.Clinical application of a new skin-stretching device
Zhengjie DANG ; Baoquan ZHANG ; Shoufeng WANG ; Xingang YANG ; Wei GAO
Chinese Journal of Tissue Engineering Research 2015;(43):7047-7052
BACKGROUND:Previously deep burn wound or skin defects are generaly repaired with skin grafting or flap of skin grafting. Obvious scar hyperplasia usualy appears after operation, which requires multiple surgeries. Meanwhile, patients have to suffer from great pain and bear high cost. OBJECTIVE: To observe the clinical effects on deep wounds by continuous traction of self-designed skin-stretching device (patent No. ZL 2012 2 0022443.7). METHODS: Thirty patients with deep burn wound, skin defect or funicular scar were enroled, including 22 males and 8 females, aged 18-49 years, and randomly divided into two groups. Skin-stretching device was adopted for skin traction treatment. Twenty cases underwent skin traction from 1 kg puling force to 5 kg, with an increase of 1 kg per 2 days, 6 hours a day for 10 days. Blood flow at the beginning, 1, 5, 10, 15, 20, 30, 60 minutes of the skin traction, and the changes of wound edge skin as wel as histological changes of the skin were observed. Of the remaining 10 cases, 2, 6, and 2 cases underwent skin traction of 2, 4, 7 kg, respectively. Blood flow and skin changes were also observed to find out the most suitable and safe force. RESULTS AND CONLUSION:Al the 30 cases achieved primary healing without necrosis of skin, infection or peripheral circulatory disorders, and the appearance and function recovered wel. The healing time was 8-24 days. The skin-stretching device was most safe under 4 kg puling force, by which, there was neither blood circulation obstacle nor tear of skin. After traction, the skin blood flow and the number of cels increased, especialy the epithelial basal cels. The colagen fibers became thicker and denser, and the elastic fibers regenerated significantly; the fibroblasts and capillary density increased. It has been proved that we can better close the wound and reduce scar formation effectively with the self-designed skin-stretching device for skin traction.
10.The effect of carbon fiber couch on dose distribution of conformal intensity modulated plan
Qingguo FU ; Xiaodong ZHU ; Haiming YANG ; Dang WEI ; Zhijie LIU
Chinese Journal of Radiation Oncology 2014;23(6):505-509
Objective To evaluate the effect of carbon fiber couch on dose distribution of radiotherapy planning and verification pass rate.Methods Establishing the carbon fiber treatment couch model in Pinnacle8.0m Treatment Planning system (TPS),and then this model was used to correct dose calculations of oblique fields in the treatment plans of 10 cases of nasopharyngeal carcinoma,10 cases of breast cancer and 10 cases of lung cancer and evaluate the effect of carbon fiber couch on the whole dose distribution of the plans.Then these plans were measured by three-dimensional dose verification equipment Delta4 to confirm the improvement extent of Gamma pass rate after considering the carbon fiber treatment couch.Results For the majority of plans,when the carbon fiber couch was taken into consideration,the target doses was significantly reduced (4772 cGy-7266 cGy vs.4859 cGy-7347 cGy,P=0.000-0.002) and the relative deviation of D95 was 1% to 3%.Measurement results of Delta4 showed that Gamma pass rate (3 mm/3% criteria) increased in all plans (96.4%-98.8% vs.93.4%-97.3%,P =0.000),some of that were up to 5 percentage when the couch model was applied.Conclusions Target doses will be overestimated if the treatment couch is ignored in TPS measurement.,However it should arouse enough attention when the disease with smaller doses corresponding gradient.