1.Spatial distribution of radiation dose field from mobile CT head scanning
Jinge ZHANG ; Wanlin PENG ; Zhenlin LI ; Chunchao XIA ; Jin PU
Chinese Journal of Radiological Medicine and Protection 2017;37(4):302-305
Objective To identify the spatial distribution of stray radiation from mobile CT head scanning for the purpose of radiation protection.Methods The head series of CareTom mobile CT were scanned and the radiation dose was measured using TLD (LiF:Mg,Cu,P).The isodose maps of radiation dose field were plotted using Matlab software.Results Radiation dose in the front of the mobile CT was slightly higher than that in the back.The maximum value of 0.255 mGy was found to be at 0.5 m from the scanning hole center.Conclusions The stray radiation dose from mobile CT head scanning was relatively low.However in order to avoid the damage to the operators and other medical workers from long-term low dose exposure,it should keep 2 m away from mobile CT,beside or behind,when in operation.
2.The clinical value of anteroposterior and lateral scout image combined with Care Dose 4D and Care kV in reducing radiation dose of chest CT scanning
Fei ZHAO ; Lei LI ; Jin PU ; Wanlin PENG ; Yuming LI ; Kai ZHANG ; Jinge ZHANG ; Keling LIU ; Chunchao XIA ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2017;37(5):389-392
Objective To investigate the feasibility and clinical value of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV in chest CT scan.Methods A total of 60 patients of clinical diagnosis with lung tumor were enrolled.Those patients were randomly divided into test group and control group.Control group underwent a scan protocol with lateral scout scan combined with Care Dose 4D and Care kV,while anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV were performed in test group.The signal-to-noise ration (SNR),contrast-to-noise ratio (CNR),and overall image quality of two groups of images and diseased tissues were analyzed and evaluated by two high-grade radiologists using double-blind method.Effective doses (E) were also calculated.Results All the 60 patients had successfully completed the chest CT scans.Test group overall image quality (4.57 ± 0.45) and control group overall image quality (4.73 ± 0.45) had no statistically significant difference (P > 0.05).The control group image SNR,CNR and diseased tissue SNR,CNR compared with test group had no statistical significance difference (P > 0.05).The difference of the volume CT dose index (CTDIvol),dose-length product (DLP) and effective dose (E) of test group and control group was statistically significant (t =8.514,8.464,8.464,P < 0.001).Compared with control group,the effective dose of test group decreased by 33.3%.Conclusions Compared with lateral scout scan,the technology of anteroposterior and lateral scout scan combined with Care Dose 4D and Care kV can decrease radiation dose without reducing the image quality.This technology can therefore be considered as a regular imaging modality for chest CT scan.
3.Application value of " one-stop" scanning of coronary and head and neck CTA using low tube voltage
Wanjiang LI ; Jianqun YU ; Tao SHUAI ; Jia TAN ; Wanlin PENG ; Zixuan LIU ; Yao ZHU ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2019;39(1):11-15
Objective To investigate the value of "one-stop" scanning of coronary and head and neck CTA in patients with normal body mass index (18 kg/m2 ≤ BMI ≤ 25 kg/m2) using low tube voltage (80 kVp).Methods In a retrospective analysis 80 patients with normal body mass index who had completed "one-stop" scanning of coronary and head and neck CTA were divided into A and B groups according to different scanning method,and 40 consecutive cases were selected in each group.Scanning parameters of group A and group B were tube voltage 80 kV,coronary CTA tube current 550 mA,head and neck CTA tube current 500 mA,and tube voltage 100 kV,coronary CTA tube current 450 mA,head and neck CTA tube current 400 mA separately.Subjective evaluation and objective evaluation were performed on the image quality of the two groups.CT values of coronary artery and head and neck CTA trunk branch vessel,contrast-to-noise ratio (CNR),image noise (SD) and effective dose between the two groups were compared.Results The image quality of both groups met the diagnostic requirements,and there was no statistically significant difference in subjective scores between two groups (P>0.05).The CT values of coronary arteries,the main branches of the head and neck (the common carotid artery,the internal carotid artery) and SD of head and neck CTA were significantly different between two groups (t=4.737,6.552,3.359,2.165,2.685,4.617,P<0.05).There was no statistically significant difference in SD of coronary CTA,CT values and CNR between head and neck vessels (middle cerebral artery) in group A and group B (P>0.05).The effective dose of coronary CTA in group A (1.16±0.20) mSy was reduced by 51.1% than that in group B (2.37±0.77) mSv.The effective dose of head and neck CTA in group A (0.37±0.03) mSv was reduced by 47.9% than that in group B (0.71 ± 0.17) mSv.Conclusions The image quality with subjective evaluation met the diagnostic requirements when using a low-tube voltage for "one-stop"scanning of coronary and head and neck CTA.The CNR values were basically consistent with the conventional scanning method,and the patient effective dose was reduced by about 50%.
4.Screening of main active components against cardiomyocyte hypoxia/reoxygen-ation injury in shexiang baoxin Pill
Lin HAN ; Chao LV ; Min LI ; Huimei HUANG ; Wanlin CHANG ; Chengcheng PENG ; Runhui LIU
Journal of Pharmaceutical Practice 2014;(3):209-211,219
Objective To build hypoxia/reoxygenation injury model in cultured neonatal rat cardiomyocyte and screen active components from Shexiang Baoxin Pill ( SBP) absorbed in blood against hypoxia/reoxygenation injury .Methods Cardiomyocytes were isolated and purified from hearts of neonatal Sprague Dawley rats (1~3 days old) and were used to build hypoxia/reoxygenation injury model.The components of SBP absorbed in blood were screened by methyl thiazolil tetracolium (MTT) colorimetic method.Results SBP showed significant protective effect against cardiomyocytes hypoxia /reoxygenation injury atthe concentration of 50 μg/ml.Ginsen-oside Rb1, Rb2, bufalin and muscone of twenty components from SBP absorbed in blood also possessed significant protective effect a -gainst cardiomyocytes hypoxia/reoxygenation injury .Conclusion SBP have the protective activity against cardiomyocytes hypoxia /reoxygenation injury , and ginsenoside Rb1, Rb2, bufalin, muscone are the main active components of SBP .This experiment offered basis for further pharmacodynamics and mechanism study of SBP .
5.Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging
Jin PU ; Chunchao XIA ; Fei ZHAO ; Lei LI ; Kai ZHANG ; Yuming LI ; Wanlin PENG ; Jinge ZHANG ; Keling LIU ; Xu XU ; Sixian HU ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2019;39(1):6-10
Objective To explore the clinical application value of second-generation dual-source CT combined with intelligent modulation and iterative reconstruction in emergency aortic dissection imaging.Methods A total of 40 emergency patients with clinical suspected aortic dissection were included in this study.Conventional scanning was performed in the control group,and large-pitch intelligent modulation and iterative reconstruction were performed in the test group.The mean CT value,mean noise,signal noise ratio(SNR),contrast noise ratio(CNR),effective dose,image quality and aortic root image quality were evaluated and analyzed.Results Totally 40 patients successfully completed CT aortic dissection imaging.There was no difference in image quality between the two groups (P> 0.05).The quality of aortic root images in the test group was better than that in the control group,and the difference was statistically significant(x2=22.556,P<0.05).The mean CT value and mean noise of aorta in the control group were slightly higher than those in the test group.However,SNR and CNR in the test group were higher than those in the control group,and the difference was statistically significant (t =-21.042,-15.924,8.530,11.495,P<0.05).The effective dose of the control group [(10.59±3.89)mSv] was significantly higher than that [(6.39±0.81) mSv] of the test group,the difference was statistically significant (t =-12.327,P<0.05).Conclusions The combined intelligent modulation technique and iterative reconstruction technique with dual-source CT large pitch scanning can meet the requirements of image quality and reduce the effective dose,and can be used as a conventional imaging method for emergency CT of aortic dissection.
6.Assessment of left ventricular function in patients with end stage renal disease: cardiac magnetic resonance imaging
Wanlin PENG ; Huayan XU ; Tianlei CUI ; Jinge ZHANG ; Keling LIU ; Chunchao XIA ; Huapeng ZHANG ; Lei LI ; Fei ZHAO ; Kai ZHANG ; Zhenlin LI
Journal of Practical Radiology 2018;34(5):666-669
Objective To assess the value of cardiac magnetic resonance (CMR) imaging in left ventricular structure and function in patients with end stage renal disease (ESRD).Methods Twenty-five patients with ESRD and 10 healthy subjects underwent CMR.Left ventricular end diastolic volume(EDV),end-diastolic diameter(EDD),end-systolic volume(ESV),end-systolic diameter(ESD),stroke volume(SV),ejection fraction(EF),LVM and interventricular septum (IVS) thickness were measured and compared.The parameters from CMR and 2DTTE were compared.Results The EF in patients with ESRD was significantly lower than that in controls (P<0.001),while ESV,ESD,IVS and LVM were respectively higher than these in controls (P<0.05).There was no significant difference (P>0.05) in ESV between CMR and 2DTTE,but EF of CMR was significantly higher than this of 2DTTE (P<0.05).There was no significant difference (P =0.296) in left ventricular systolic functional category.Bland-Altman plots showed a good agreement between the two methods.Conclusion CMR is a helpful tool to assess left ventricular structure and function in patients with ESRD.
7.Quantitative assessment of myocardial microcirculation damage in patients with end-stage renal disease by CMR
Rong XU ; Yingkun GUO ; Zhigang YANG ; Xi WU ; Zhenlin LI ; Chunchao XIA ; Huayan XU ; Wanlin PENG ; Yi ZHANG
Journal of Practical Radiology 2018;34(6):873-877
Objective To quantitative evaluate the myocardial microcirculation dysfunction in patients with end-stage renal disease (ESRD),and to provide the imaging characteristic for early detection myocardial dysfunction and microcirculation damage in the ESRD patients after dialysis therapy.Methods Sixty-seven patients with ESRD and 1 9 healthy subj ects were enrolled in our study, and the ESRD patients were divided into two groups including patients with preserved systolic function (n=51,EF≥50%)and patients with impaired systolic function (n=16,EF<50%).The LV regional myocardial perfusion parameters were analyzed including upslope, time to maximum signal intensity (TTM)and max signal intensity (Max SI).Those continuous variables were compared using one-way analysis of variance (A N OVA )in all three groups.Results Compared with the controls and the ESRD patients with preserved EF,the ESRD patients with impaired EF had a significantly lower SV and markedly increased LV mass (all P<0.001).For the fist-pass perfusion analysis,first-pass perfusion Max SI of all segments were significantly reduced in the ESRD patients with preserved/impaired EF compared with the normal subjects (all P<0.05).Compared with the ESRD patients with preserved EF and controls,the ESRD patients with impaired EF had lower upslope in the basal segment (P<0.05).And the ESRD patients with preserved/impaired EF had shorter TTM in the apical segment than that in normal controls (P<0.01).Conclusion The CMR first-pass perfusion can detect the myocardial deformation and dysfunction in ESRD patients,the Max SI may be more valuable to early detect myocardial microcirculation dysfunction.
8.Pharmacology and Clinical Evaluation of Ensartinib Hydrochloride Capsule.
Yang WANG ; Xiaobin YUAN ; Jiayan XIONG ; Zhidong HAO ; Xingzhe PENG ; Wanlin CHEN ; Lingling CUI ; Hua LI ; Xiulan WANG ; Xiangbo HE ; Min YANG ; Congxin LIANG ; Yongbin MA ; Lieming DING ; Li MAO
Chinese Journal of Lung Cancer 2020;23(8):719-729
Lung cancer is one of the most common malignancies with the highest incidence rate and mortality rate worldwide, and non-small cell lung cancer (NSCLC) accounts for about 85%. Only 5% NSCLC patients are anaplastic lymphoma kinase (ALK) rearrangement positive NSCLC, but the prognosis of these patients is poor, and treatment is urgent. Ensartinib (X-396), a next-generation ALK tyrosine kinase inhibitor (ALK-TKI), has shown greater potency on inhibiting ALK activity and controlling brain metastases than crizotinib, which is indicated for the treatment of crizotinib-resistant, ALK-positive NSCLC patients. Several phase I to III clinical trials included both healthy volunteers and NSCLC patients have been conducted both in China and abroad. In this review, we briefly summarized the results of these trials, and preliminary efficacy, safety, pharmacology and pharmacokinetics/pharmacodynamics of ensartinib were discussed.