1.Genetic Variation of Anopheles dirus A and D (Diptera:Culicidae) in China: Inferred by mtDNA-COⅠ Gene Sequences
Dong WANG ; Yajun MA ; Hongning ZHOU
Chinese Journal of Parasitology and Parasitic Diseases 1997;0(05):-
Objective To interpret genetic variation and population structure of Anopheles dirus A and D from China by molecular marker. Methods Samples included An. dirus A of Hainan laboratory colony (n=13), and field specimen from Mengla (n=17) and Jiangcheng (n=17) in Yunnan Province. The specimens were identified by PCR assay before study. mtDNA-COⅠ region was amplified and sequenced. Genetic variation and population structure was estimated according to sequence data. Results The mtDNA-COⅠ gene with a length of 959 bp was analyzed. There were three haplotypes in An. dirus A and six haplotypes in An. dirus D. The above haplotypes distributed in three populations unif-ormly. The average number of pairwise differences within Mengla population (7.441 2) was greater than that of Jiangcheng (1.279 4) and Hainan (1.051 3) populations, which suggested that the level of genetic divergence was the highest within Mengla population. The result of hierarchical AMOVA estimation showed a limited geneflow (Fst=0.799 9), therefore the variation level in a population (20.01%) was smaller than among the populations (79.99%). Conclusion The inter-specific genetic variation between An. dirus A and D in China was small and the level of divergence among individuals was high.
2.Practice and exploration of resident standardization training for echocardiography
Xiao ZHI ; Hong ZHOU ; Feng LI ; Yueheng WANG ; Hongning YIN
Chinese Journal of Medical Education Research 2016;15(12):1268-1271,1272
Resident standardization training is a major part of education of medical students after graduation , and is extremely important for high-level physician training and raising the quality of medical treatment. We trained the residents comprehensively according to the characteristics of echocardiography in terms of theoretical knowledge, clinical manipulative skills, clinical thinking ability, scientific research ability and communication and team cooperation ability, and carried out the relative examination according to the training. On the basis of practice, we explored the establishment of a standardized training mode and evaluation system suitable for echocardiography resident doctors in China.
3.Serological survey of Toxoplasma gondii infection in some areas of Pu’er City
Fangwei WU ; Libo WANG ; Zunwei DU ; Hongning ZHOU ; Jinyong JIANG ; Xianghua MAO ; Xuezhong WANG
Chinese Journal of Schistosomiasis Control 2014;(5):583-585
Objective To understand the status of Toxoplasma gondii infection in the population of Pu er City so as to pro-vide the evidence for formulating the strategy of toxoplasmosis control. Methods The population from Jingdong Jinggu and Menglian counties in Pu er City was surveyed IgG of T. gondii in serum was detected by ELISA. Results Totally 906 resident serum samples were detected and the IgG positive rate was 24.2%. The positive rates were higher in the aged groups of 30-39 years and 60-69 years and the difference among different aged groups was significant χ2=17.77 P 0.01 . There were no si-gnificant differences between different sexualities and among different educational levels and living habits P 0.05 . The posi-tive rates were 26.6% 194/730 15.5% 22/142 and 8.8% 3/34 in farmers students and other occupations respectively and there was a significant difference among them χ2=12.51 P 0.01 . The positive rates were 23.3% 198/849 and 36.8%21/57 in the farmers who had the habit of rearing pigs in pens and the farmers who had the habit of free ranging pigs respec-tively and there was a significant difference between them χ2=5.33 P 0.05 . Conclusion The IgG positive rate of T. go-ndii is very high in Pu er City and therefore the health education for toxoplasmosis control should be strengthened.
4.Clinical value of two-dimensional and real-time three-dimensional transesophageal echocardiography for the guidance of left atrial appendage closure:a comparison study for LAmbre device selection
Yijia WANG ; Qing ZHOU ; Bin XIE ; Hongning SONG ; Lan ZHANG ; Bin KONG ; Tuantuan TAN ; Bo HU
Chinese Journal of Ultrasonography 2015;(4):282-286
Objective To explore the clinical value of two‐dimensional transesophageal echocardiography (2D‐TEE) and real‐time three‐dimensional transesophageal echocardiography (RT3D‐TEE) for the left atrial appendage (LAA) closure procedures by the visualization of LAA shape by 2D‐TEE and RT3D‐TEE and the comparison between the measurement of LAA ostium and the sized LAmbreTM device during the procedure .Methods Forty‐one atrial fibrillation patients ,who had undergone 2D‐TEE examination at our hospital ,were enrolled in the study .At the mid‐esophageal ,dimensions of inner and outer ostium and depth of LAA were measured at the 2D‐TEE views of 0 ,45 ,90 and 135 degree respectively . RT3D‐TEE views were acquired and the maximal and the minimal dimensions of LAA inner ostium were measured .The measurement by RT3D‐TEE and 2D‐TEE were compared to find the difference and correlation .Eleven of 41 patients who have complied with the requirements for the LAA closure ,were undergone the procedures ,measured the dimension of LAA inner ostium at selective angiography intraoperative .Sizes of closure disks of the closure device and the measurement at selective angiography were recorded to compare the measurement at RT3D‐TEE and 2D‐TEE .Results Forty‐one atrial fibrillation patients were completed TEE examination successfully .Inner ostial dimension of LAA was (20.0±04.3)cm,(19.7±03.8)cm,(21.2±04.6)cm,(23.0±05.0)cmat2D‐TEEviewsof0,45,90and135 degree ,respectively .The maximum dimensions of LAA inner ostium by RT3D‐TEE was (2 4.9 ± 0 5.2)cm . At 2D‐TEE views ,the maximum dimensions of LAA inner ostium was at 135 degree ,there was a difference between it and the measurement by RT3D‐TEE ( P =0 0.12) .Monitoring by TEE ,LAA closure procedures with LAmbreTM device were successful for all 11 patients ,the landing zone by selective angiography was (2 4.9 ± 0 4.4)cm ,and the appropriate sized closure disk of the LAmbreTM device was 2 4. - 3 6. cm . Correlation between the measurements by RT3D‐TEE and selective angiography and the sized closure disk were r =0 8.16 ,P =0 0.02 and r =0 9.14 ,P =0 0.00 ,respectively .Correlation between the measurements by 2D‐TEE and selective angiography and the sized closure disk were r =0 6.93 ,P =0 0.18 and r =0 6.88 , P=0 0.19 ,respectively .Conclusions There was better correlation among the measurements by RT3D‐TEE and selective angiography and the size of closure device .Therefore ,compared to 2D‐TEE ,the guidance of RT3D‐TEE was more accurate during LAA closure procedures for LAmbreTM device selection .
5.Indirect ultrasonic signs of the callosal partial agenesis and hypoplasia in the fetus
Danlei CAI ; Lijuan LI ; Nan WANG ; Lihong WU ; Liu DU ; Hongning XIE
The Journal of Practical Medicine 2014;(20):3302-3304
Objective To investigate antenatal sonographic findings of the fetal isolated callosal hypoplasia and partial agenesis. Methods A retrospective study was performed on the cases of hypoplasia and partial agenesis of the corpus callosum suspected at antenatal sonographic basic examination from 2006 to 2014, all the cases were confirmed by pathology or magnetic resonance imaging(MRI). For the surviving infants, clinical follow-up had been performed to assess the developmental outcome. Results Thirteen fetuses suspected with callosal underdevelopment were identified at a median gestational age of 31 (range, 18~39) weeks. Ten cases were confirmed by autopsy and MRI, including 9 with partial agenesis and 1 with hypoplasia. Among the 10 fetuses confirmed with isolated partial agenesis or with hypoplasia, incidence of the absent cavum septum pellucidum was 20%, the ‘Tear-drop’ lateral ventricles was 40%, the upward displacement of the third ventricle was 80%. Pregnancy was terminated electively in 8 of the cases with partial agenesis or with hypoplasia. Among the 2 surviving infants, apparent normal development was observed in only one case, but we lost the follow-up of this case at two-year-old. Six fetuses received the chromosome identification, almost all of them were normal. Conclusion The basic ultrasonic examination is feasible for the antenatal diagnosis of isolated callosal underdevelopment the. The indirect classical signs of callosal partial agenesis and hypoplasia are different with those of complete agenesis of the corpus callosum. The incidences of the‘Tear-drop’ lateral ventricles and the upward displacement of the third ventricle are higher than the absence of CSP. The chromosome of isolated callosal partial agenesis or hypoplasia is normal, however, the prognosis is uncertain.
6.The effect of low-frequency transcranial magnetic stimulation pretreatment on seizures, the expression of B
Sha KE ; Hongning ZHANG ; Junqiang ZHANG ; Xiaoming WANG ; Xiaoqiong ZHAO ; Hui HUANG ; Jianxiu HU
Chinese Journal of Physical Medicine and Rehabilitation 2011;33(7):488-493
Objective To study the possible mechanisms by which repetitive transcranial magnetic stimulation (rTMS) pretreatment antagonizes seizures induced by lithium chloride-pilocarpine and any correlation with antiapoptosis in hippocampal CA1 neurons.Methods Thirty rats were randomly divided into a control group, a sham stimulation group and an rTMS pretreatment group. The rTMS pretreatment group was pretreated on 7 consecutive days with low-frequency rTMS (0.5 Hz, 75% of threshold intensity, 20 times/bundle, and 5 bundles/d), while the sham-stimulation group was sham-stimulated with a similar sound. Lithium chloride-pilocarpine ( LPC ) was used to induce a model epileptic state.Epileptic stroke latency and severity were recorded ; neuronal morphology was observed using hematoxylin and eosin (HE) staining; mean positive-reactive cell number and mean optical density and absorbance of B cell lymphoma/leukemia gene-2 (Bcl-2) were recorded, and Fas and Caspase-3 protein in the hippocampal CA1 region were observed with immunohistochemistry.Results Compared with the sham stimulation group, epileptic latency in the rTMS pretreatment group was significantly longer. Seizures in the rTMS pretreatment group were less severe, and a number of degenerated neurons were observed to be apoptotic. Bcl-2 protein expression increased at each time point, but Fas and Caspase-3 protein expression decreased.Conclusions rTMS pretreatment has an anti-epilepsy effect. The possible neuronal protection might be produced by regulating the expression of Bcl-2, Fas and Caspase-3 protein in the hippocampus.
7.Comparison between the aorta and pulmonary artery dimensions z-score in fetus with tetralogy of Fallot and normal fetus
Lihong WU ; Hongning XIE ; Lan LI ; Nan WANG ; Ju ZHENG ; Yunxiao ZHU
Chinese Journal of Ultrasonography 2014;23(7):577-580
Objective To establish z-score model for fetal aorta (Ao) and pulmonary artery (PA) dimensions base on fetal femur length (FL),then to evaluate them in prenatal diagnosis of tetralogy of Fallot (TOF).Methods Three hundred twenty-nine normal fetuses and 43 fetuses with TOF were involved,Ao and PA dimensions were measured for all cases offline after cardio-spatiotemporal image correlation (STIC) volume acquisition,and PA to Ao ratio (PA/Ao) was calculated.Normal Ao and PA dimensions z-score models were constructed by using first standard regression analysis using FL as independent variable.Subsequently,the three parameters between normal and TOF fetuses were compared.Results The models use to calculate z-score for Ao and PA dimensions were constructed,FL had close correlation with fetal Ao and PA dimensions.Compared with normal fetuses,the mean z-scores of Ao,PA and PA/Ao ratio were statistical different in TOF fetuses.All Ao z-scores were > + 2 z-scores and all the PA/Ao ratio were < the 95% CI in TOF group,however,only 48.84% (21/43) PA z-scores of TOF cases were <-2 z-scores.Conclusions The Ao and PA dimensions z-score can provide quantitative evidence in prenatal diagnosis of TOF.Aortic dilatation and abnormal PA/Ao ratio are the main performances in fetal TOF and would be markers for prenatal diagnosis of TOF.
8.Comparison efficiency of three-dimensional speckle tracking and two-dimensional speckle tracking imaging in detecting significant coronary artery stenosis
Caiying WANG ; Qing ZHOU ; Caizhi ZHANG ; Jinling CHEN ; Bo HU ; Hongning SONG ; Ruiqiang GUO
Chinese Journal of Ultrasonography 2013;22(8):654-658
Objective To analyzed the left ventricular (LV) regional and global strains in coronary artery stenosis by using three-dimensional speckle tracking imaging (3D-STI) and two-dimensional speckle tracking imaging (2D-STI) for the assessment of left ventricular systolic function,and to compare the clinical values between 3D-STI and 2D-STI in the detection of coronary stenosis.Methods 39 patients with coronary artery stenosis and 32 sex-age matched controls were enrolled in this study.Coronary artery stenosis group was divided into ischemic group and non-ischemic group.Real-time three dimensional full volume and two-dimensional dynamic image of the LV were obtained and then analyzed by off-line analysis software.The parameters of 3D-STI were three-dimensional longitudinal strain (3D-LS),circumferential strain (3D-CS),radial strain (3D-RS),area strain (3D-AS),global longitudinal strain (3D-GLS),global circumferential train (3D-GCS),global radial strain (3D-GRS) and global area strain (3D-GAS).The parameters of 2D-STI were two-dimensional longitudinal strain (2D-LS),circumferential strain (2D-CS),radial strain (2D-RS),global longitudinal strain (2D-GLS),global circumferential train (2D-GCS) and global radial strain (2D-GRS).The global/regional strains derived from 3D-STI and 2D-STI in patient group and controls were analyzed for comparing their efficacy in detecting coronary artery stenosis.Results Compared with non-ischemic group,2D-LS,2D-CS,3D-LS,3D-CS and 3D-AS were lower in ischemic group (P <0.05).ROC curves showed the sensitivity of 2D-LS,3D-LS and 3D-AS for the diagnosis of myocardial ischemia was 60.1%,64.2 % and 74.0 %,while the specificity of them was 60.0%,61.0% and 63.1%,respectively.There was no significant difference in 2D-GCS and 2D-GRS between coronary artery stenosis group and control group (P > 0.05).Compared with control group,2D-GLS,3D-GLS,3D-GCS,3D-GRS and 3D-GAS were significantly lower in coronary artery stenosis group (P <0.05).ROC curves showed the sensitivity of 2D-GLS,3D-GLS and 3D-GAS in the diagnosis of coronary artery stenosis was 61.3%,73.3% and 79.3 %,while the specificity was 65.4%,66.0 % and 70.8 %,respectively.The sensitivity and specificity of 3D-GAS were the highest in these parameters.It is revealed that 2D-GLS,2D-GCS and 2D-GRS were correlated with LVEF (r1 =-0.668,P1 <0.001 ;r2 =-0.551,P2 <0.001 ;r3 =0.310,P3 <0.05),and 3D-GLS,3D-GCS,3D-GRS,3D-GAS were correlated with LVEF (r1 =-0.634,P1 <0.001 ;r2 =-0.672,P2<0.001 ;r3 =0.698,P3<0.001 ;r4 =-0.707,P4<0.001).The correlate of 3D-GAS and LVEF was higher than other parameters.Conclusions 3D-STI is superior to 2D-STI in assessing regional and global left ventricular systolic function in patients with coronary artery stenosis,and 3D-GAS derived from 3D-STI is a ideal parameter of detecting significant coronary artery stenosis based on its highest sensitivity and specificity.
9.The application of real-time three-dimensional transesophageal echocardiography in percutaneous left atrial appendage closure
Yijia WANG ; Qing ZHOU ; Hongning SONG ; Lan ZHANG ; Bo HU ; He HUANG ; Bin KONG
Chinese Journal of Ultrasonography 2015;(9):753-757
Objective To evaluate the application of real-time three-dimensional transesophageal echocardiography (RT-3D TEE)in left atrial appendage (LAA)closure.Methods After excluding valvular disease,21 of 36 atrial fibrillation (AF)patients suffered the percutaneous LAA closure were chosen to measure left ventricular ejection fraction (LVEF)and to observe if the thrombus or the cloudiness echo will occur.The multiple planner reconstruction function was applied to rebuild sections and to observe the LAA anatomical morphology and its internal structure.During operation,the Flexi Slice function was used to measure the dimensions of LAA ostium,RT-3D mode was used to monitor sheath transport and closure device release,and to immediately evaluate the effect of blocking and complications after the operation. Results The exam before the closure procedure showed 5 of 36 patients' left ventricular ejection fraction (LVEF)<40% and one or more thrombus or the cloudiness echo were found in other 10 patients' which were thus excluded from the study.RT-3D TEE examination in the 21 patients revealed 8 single-lobe cases, 8 double-lobes cases and 5 patients with multi-lobe.Two patients of them need a special device.The maximum dimensions of LAA ostium was (22.24±4.35)mm,the fixed plate size of conventional LAmbreTM device was (28.26±5.23)mm.All patients choiced an average (1 .1 ±0.30)closure device and get the best sealing effect evaluated by RT-3D TEE immediately after operation,10 cases of them has about 1 -3 mm residual leakage exist around the closure.None of the patients with a new pericardial effusion and cardiac tapenade,no closure shift and embolism events.Conclusions RT-3D TEE can real-time and dynamically observe LAA anatomical morphology and its internal structure,compared with other imaging techniques, RT-3D TEE has irreplaceable advantages in the percutaneous LAA closure.
10.Evaluation of the Enzyme-linked Immunosorbant Assay in Detecting Circumsporozoite Protein of Anopheline Vectors in Yunnan
Hongning ZHOU ; Zaixing ZHANG ; Curtis CHRIS ; Hill NIGEL ; Chunfu LI ; Chao WU ; Piyu WANG
Chinese Journal of Parasitology and Parasitic Diseases 1987;0(04):-
Objective To detect circumsporozoite protein (CSP) in anopheline vectors from south Yunnan and to evaluate ELISA in the detection. \ Methods\ Salivary glands of the anopheline mosquitoes were taken for finding sporozoites by microscopy and part of the glands was used for detecting CSP by ELISA. An. minimus was experimentally infected by blood from vivax malaria patient (with Plasmodium vivax) and examined for sporozoites and CSP. Eight species of anopheline mosquitoes were caught in the field and examined. Monoclonal antibodies to P.falciparum (Pf2A10) and P.vivax (Pv210, Pv247) were used in ELISA for detecting CSP. \ Results\ Sporozoites were found in the salivary glands of 27 out of 36 An. minimus experimentally infected (75\^0%), 29 were ELISA CSP positives (80\^6%), and 26 of the 27 mosquitoes showed Pv210 CSP positive. Among \{1 010\} parous anopheline mosquitoes from the field, 7 were found sporozoite positive (0\^69%), 8 were ELISA CSP positive (0\^79%), and 6 of the 7 mosquitoes showed CSP positive. Of \{4 675\} wild mosquitoes in 8 anopheline species with different ages, 11 were found CSP positive (0\^24%) including An.minimus, An.sinensis and An.maculatus with a positive rate of 0\^20%, 0\^24% and 0\^39% respectively.Among the 11 mosquitoes, 9 were Pv210 positive and 2 were Pf2A10 positive. Conclusion CSP detection by ELISA is a useful method to monitor the malaria transmission capacity of anopheline vectors.