1.Permanent Pacemaker Lead Induced Severe Tricuspid Regurgitation in Patient Undergoing Multiple Valve Surgery.
Jung Hee LEE ; Tae Ho KIM ; Wook Sung KIM
The Korean Journal of Thoracic and Cardiovascular Surgery 2015;48(2):129-133
Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.
Humans
;
Tricuspid Valve
;
Tricuspid Valve Insufficiency*
2.Balloon Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis.
Emmanouil PETROU ; Vasiliki VARTELA ; Chrysafios GIRASIS ; Maria BOUTSIKOU ; Ioannis IAKOVOU ; Gregory PAVLIDES
Korean Circulation Journal 2014;44(2):128-129
No abstract available.
Balloon Valvuloplasty*
;
Tricuspid Valve Stenosis*
;
Tricuspid Valve*
4.Tricuspid valve repair in the patients with mitral valve replacement .
Jong Bum CHOI ; Jae Do YOON ; Jin Woo JEONG
The Korean Journal of Thoracic and Cardiovascular Surgery 1991;24(4):323-330
No abstract available.
Humans
;
Mitral Valve*
;
Tricuspid Valve*
5.Tricuspid Regurgitation, Isn't It Time to Look Around the Valve Rather Than the Valve Itself?.
Journal of Cardiovascular Ultrasound 2015;23(3):134-135
No abstract available.
Tricuspid Valve Insufficiency*
6.A Simple Two-Dimensional Echocardiographic Sign of Tricuspid Regurgitation.
Jong Hoa BAE ; Chuwa TEI ; G VIJAYARAGHAVAN ; George CHERIAN ; Pravin M SHAH
Korean Circulation Journal 1985;15(2):269-276
No abstract available.
Echocardiography*
;
Tricuspid Valve Insufficiency*
7.Three-dimensional Reconstruction of Tricuspid Annulus with the Duran Ring.
Dong Gon YOO ; Chong Wook KIM ; Chong Bin PARK ; Suk Jung CHOO ; Jae Won LEE
The Korean Journal of Thoracic and Cardiovascular Surgery 2005;38(1):88-90
Tricuspid annuloplasty with the flexible Duran ring may result in a physiologic repair while maintaining the dynamic morphology of the tricuspid annulus. A method for a durable three-dimensional tricuspid annular reconstruction, which retains the plasticity and orifice area of the tricuspid annulus, is described.
Plastics
;
Tricuspid Valve
8.Clinical study on surgical treatment of acquired tricuspid regurgitation.
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(3):196-203
No abstract available.
Tricuspid Valve Insufficiency*
9.Quadrangular Resection of the Tricuspid Valve.
Jae Ho KIM ; Young Sam KIM ; Yong Han YOON ; Joung Taek KIM ; Kwang Ho KIM ; Wan Ki BAEK
The Korean Journal of Thoracic and Cardiovascular Surgery 2013;46(1):60-62
Quadrangular resection is the gold standard technique for correction of the posterior leaflet prolapse in mitral valve disease. Prompted by the idea that the anterior leaflet of the tricuspid valve corresponds to the posterior leaflet of the mitral valve in its structure and function, we conducted a quadrangular resection of the anterior leaflet of the tricuspid valve in a case of tricuspid endocarditis. Tricuspid regurgitation was well corrected, and the durability of the repair was proven by the patient's freedom from cardiac events for the following 8 years.
Endocarditis
;
Freedom
;
Mitral Valve
;
Prolapse
;
Tricuspid Valve
;
Tricuspid Valve Insufficiency
10.Is tricuspid valve really tricuspid?.
Sunita ATHAVALE ; Rashmi DEOPUJARI ; Urmila SINHA ; Rekha LALWANI ; Sheetal KOTGIRWAR
Anatomy & Cell Biology 2017;50(1):1-6
Advancement in imaging techniques and interventional cardiology procedures have generated renewed interest in anatomy of tricuspid valve complex. The purpose of the present study was to characterize the morphology of tricuspid valve leaflets using objective criteria. Thirty-six embalmed cadaveric hearts were utilized for the present study. Leaflet morphology was studied using newly defined criteria. Commissural zones were identified and leaflets were delineated. Presence of scallops was also recorded. Single leaflet was observed in six cases, double in 26 cases, and triple in four cases. The anterior leaflet is large with multiple scallops and frequently accrues portion of inferior leaflet. The septal leaflet is in the form of a plateau and also frequently accrues parts of inferior leaflet. The inferior leaflet rarely occurs as independent leaflet. A wide un-indented basal zone exists across the valve leaflets. The study found that the tricuspid valve is rarely tricuspid. It also generated the hypotheses that the tricuspid valve does not open completely due to presence of a wide basal zone and the valve does not close completely owing to incongruence and lack of coaptation of leaflets. The findings provide clear understanding of leaflet morphology of tricuspid valve. This will help imaging specialists for interpretation of images and cardiologists for interventional procedures. The findings also enhance our understanding of pathophysiology of conditions like functional tricuspid regurgitation.
Cadaver
;
Cardiology
;
Heart
;
Pectinidae
;
Specialization
;
Tricuspid Valve Insufficiency
;
Tricuspid Valve*