1.Antidepressant effects of icariin in prenatally stressed offsprings
Xiaoxiao ZHANG ; Tianwei LIN ; Junli ZHANG ; Lin ZHANG ; Juanping XIE ; Hui LI ; Zhongliang ZHU
Chinese Pharmacological Bulletin 2017;33(7):987-991
Aim To observe the effects of icariin on depressive-like behavior in prenatally stressed offsprings and explore its mechanism.Methods The model of depression was established by prenatal restraint stress on late pregnant mother, then male offspring rats were randomly divided into five groups of eight: Control, PS model, Saline group(NS), ICA(80 mg·kg-1), ICA(40 mg·kg-1).The effects of icariin on PS-induced depressive-like behaviors in male offsprings were examined by forced swimming test(FST) and open-field test(OFT).Furthermore, the protein expressions of group I metabotropic glutamate receptors(I mGluRs) and excitatory amino acid transporter 2(EAAT2) in prefrontal cortex were detected by Western blot.Results PS group exhibited depressive-like behaviors with decreased struggling time(P<0.01) and center crossing numbers(P<0.05) compared to CON, with increased protein expressions of group I mGluRs(P<0.01,P<0.05) and decreased EAAT2(P<0.05) in prefrontal cortex compared to CON.Treatment with icariin(80 mg·kg-1, 40 mg·kg-1)significantly increased struggling time(P<0.05,P<0.01) and center crossing numbers(P<0.05) in PS-exposed male offspring rats.Treatment with icariin markedly modulated the protein levels of mGluR1, mGluR5 and EAAT2 in prefrontal cortex.Conclusion Icariin has significant antidepressant effects in prenatally stressed rats, and the mechanism might be associated with the modulation of Ⅰ mGluRs.
2.Robot-assisted radical cystectomy with total intracorporeal ileal conduit: comparative analysis with extracorporeal ileal conduit
Jiale TIAN ; Tianwei YUN ; Wei ZHANG ; Yongming DENG ; Tingsheng LIN ; Yifan SUN ; Rong YANG ; Shiwei ZHANG ; Weidong GAN ; Xiaogong LI ; Gutian ZHANG ; Hongqian GUO
Chinese Journal of Urology 2021;42(7):524-529
Objective:To compare the perioperative complications and prognosis of intracorporeal and extracorporea lileal conduit urinary diversion(ICUD or ECUD)following robot-assisted radical cystectomy(RARC).Methods:The data of 95 patients who underwent RARC treatment in Nanjing Drum Tower Hospital from March 2016 to June 2019 were retrospectively analyzed. Among them, 37 underwent ICUD and 58 underwent ECUD. In the ICUD group, there were 32 males and 5 females, aged(68.0±7.8) years, body mass index (BMI) of (24.1±3.4) kg/m 2, American Society of Anesthesiologists(ASA)score of 1-2 in 4 cases(10.8%), ASA score of 3-5 in 33 cases(89.2%), preoperative hemoglobin of(126.5±14.2)g/L, albumin of(39.0±2.2)g/L, and C-reactive protein of 4.0(2.0-8.5) mg/L. In the ECUD group, there were 53 males and 5 females, aged(67.5±9.0)years, BMI of(24.2±3.6)kg/m 2, ASA score of 1-2 in 16 cases(27.6%), ASA score of 3-5 in 42 cases (72.4%) , preoperative hemoglobin of(129.0±12.4)g/L, albumin (38.2±3.1) g/L, and C-reactive protein of 4.9 (3.1-14.4) mg/L. There was no significant difference in preoperative data between the two groups ( P>0.05). The two groups underwent RARC and pelvic lymph node dissection similarly. The ICUD group underwent a total intracorporeal ileal conduit and the ECUD group underwent extracorporeal ileal conduit with direct vision through a median incision in the lower abdomen.There were 32 cases (86.5%) and 46 cases (79.3%) undergoing expanded pelvic lymph node dissection in the ICUD group and the ECUD group respectively, and the difference was not statistically significant ( P=0.374). The complications were graded according to the Clavien-Dindo grading system. The perioperative complications and prognosis of the two groups were compared. Results:The operation time of the ICUD group and the ECUD group were (430±63) min vs. (410±69) min, respectively ( P=0.163). The estimated blood loss were (435±233) ml vs. (388±277) ml, respectively ( P=0.182). Intraoperative blood transfusion were 10 cases (27.0%) and 12 cases (20.7%)( P=0.475). None of the above differences were statistically significant. Postoperative albumin of the ICUD group and the ECUD group were (31.5±2.4) g/L vs. (31.0±2.8) g/L ( P=0.387), postoperative C-reactive protein were 30.9 (10.4-52.1) mg/L vs.29.5 (14.4-58.5) mg/L ( P=0.655) and postoperative hemoglobin were (110.0±13.8) g/L vs. (113.7±13.4) g/L ( P=0.187). The postoperative feeding recovery were 4(3-5) d vs. 4(3-5) d ( P=0.752) and the postoperative hospital stay were 13(10-19) d vs. 13(11-18) d ( P=1.000). There was no statistically significant difference in perioperative data. The postoperative pathological examination results of ICUD group and ECUD group showed that there were 17 cases (45.9%) vs.19 cases (32.8%) in T a/T 1/Tis stage, 12 cases (32.4%) vs. 18 cases (31.0%) in T 2 stage, 5 cases (13.5%) vs. 19 cases (32.8%) in T 3 stage, 3 cases (8.1%) vs. 2 cases (3.4%) in T 4 stage, respectively and the difference was not statistically significant( P=0.166). The number of lymph nodes removed were (18.2±6.7) vs.(16.5±7.9)( P=0.178) and the number of patients with positive lymph nodes were 6(16.2%) vs.11(19.0%), respectively( P=0.733). None of the patients had positive margins. There was no statistically significant difference in pathological examination overall. There were 14 cases (37.8%) in the ICUD group and 21 cases (36.2%) in the ECUD group experiencing complications within 30 days after operation and the difference was not statistically significant( P=0.872). The complications within 90 days after operation were 14 cases (37.8%) vs. 24 cases (41.4%) respectively and the difference was not statistically significant( P=0.731). Clavien-Dindo grade Ⅲ-Ⅴ complications in the two groups were 1 case (2.7%) vs.1 case (1.7%) respectively, with no significant difference ( P=0.849). One patient in the ICUD group developed an intestinal anastomotic leakage and underwent reoperation for repairing and 1 patient in the ECUD group developed mechanical intestinal obstruction and underwent reoperation. The rate of readmission within 90 days after operation of the ICUD group was lower than that of the ECUD group, but the difference was not statistically significant [3 cases (8.1%) vs. 11 cases (19.0%), P=0.090]. Postoperative follow-up was 13-53 months and the median follow-up of ICUD group and ECUD group were 19 months and 31 months respectively. There was no significant difference in the survival curve between the two groups( P=0.746). The 1-year survival rate was 91.9% in the ICUD group and 91.4% in the ECUD group. Routine re-examination of urinary system CT or B-ultrasound was performed 3 months, 6 months and 1 year after surgery. The incidence of ureteral dilatation/hydronephrosis in the ICUD group was lower than that of the ECUD group, with 4.1%(3 sides) vs. 14.7%(17 sides)( P=0.020). Conclusion:Compared with RARC+ ECUD, RARC+ ICUD does not increase the incidence of complications within 90 days after surgery and may reduce the risk of upper urinary tract dilatation.
3. Current status of occupational exposure to power frequency electromagnetic field in converter stations
Guoyong XU ; Xinqi LIN ; Zhipeng HE ; Lei LIU ; Bin LI ; Tianwei LI ; Yongxin LIANG
China Occupational Medicine 2020;47(06):681-685
OBJECTIVE: To analyze the current status of occupational exposure to power frequency electromagnetic field in converter stations. METHODS: Eight converter stations with voltage levels of ±500 kV and ±800 kV within normal operation were selected as the research subjects using the typical sampling method. Power frequency electric field and power frequency magnetic field strengths were measured and calculated according to the GBZ/T 189.3-2018 Measurement of Physical Agents in Workplace--Part 3: Electric Field and Magnetic Field between 1 Hz and 100 kHz. The GBZ 2.2-2007 Occupational Exposure Limits for Hazardous Factors in the Workplace--Part 2: Physical Factors were used to evaluate whether the power frequency electric field strength exceeds the regulatory limit(the occupational exposure limit of power frequency electric field in 8 hours workplace is 5.000 kV/m). Meanwhile, the test results were evaluated according to the short-term occupational exposure limit of 50 Hz electric field and magnetic field recommended by the International Committee on Nonionizing Radiation Protection in 2010 that are 10.000 kV/m and 1 000.00 μT. RESULTS: The power frequency electric field and magnetic field strengths of 582 working environment detection points were measured. The median and 0-100 th percentile of power frequency electric field and power frequency magnetic field strength were 4.342(0.001-12.003) kV/m and 5.51(0.10-186.90) μT, respectively.The exceeding standard rate of power frequency electric field strength in converter station workplaces was 37.8%(220/582), which concentrated in 500 kV alternating current filter area and 500 kV alternating current field area. Among them, 5 detection points had power frequency electric field strength exceeding 10.000 kV/m. The magnetic flux density of all the detection points did not exceed 1 000.00 μT. The power frequency electric field strength in ultra-high voltage region was higher than that in high voltage region(P<0.01). There was no significant difference in power frequency magnetic field strength(P>0.05). There was no significant difference in power frequency electric field and magnetic field between rectifier stations and inverter stations(P>0.05). The 8 hours time weighted average(TWA) value of power frequency electric field strength of 8 converter station operators was 1.044-2.335 kV/m, which did not exceed the occupational exposure limit. CONCLUSION: The converter station operators might be exposed to excessive power frequency electric fields for a short time, but the 8 hours TWA value of the power frequency electric field meets the requirements of standards, and the power frequency magnetic field exposure strength also meets the requirements of the relevant standards.
4.Preparation Methods and Evaluation Criteria Analysis of Animal Models for Perimenopausal Syndrome
Tianwei LIANG ; Yasheng DENG ; Hui HUANG ; Na RONG ; Xin LIU ; Yujie WANG ; Jiang LIN
Laboratory Animal and Comparative Medicine 2024;44(1):74-84
Objective To comprehensively analyze the reported preparation methods for animal models of perimenopausal syndrome (PS), to compare the advantages and disadvantages of various preparation elements and detection indexes, so as to provide useful references for the optimization of the relevant animal models as well as the standardization of their application in the efficacy evaluation of new drugs.MethodsIn this paper, literature research methods were applied using "perimenopausal syndrome" as the subject term. The publication period of the literature was limited to January 2016 to February 2023. Relevant literature on the preparation of PS animal models was retrieved from databases such as China National Knowledge Infrastructure, Wanfang database, and PubMed. After screening the experimental literature that met the inclusion and exclusion criteria, detailed information on experimental animal strains, modeling methods, duration of drug administration, positive drugs, detection indexes and other relevant information were collected. After the above information was standardized, the PS animal model database was established using Excel 2010 software. The model preparation elements and evaluation indexes were summarized systematically, and the statistical results were processed and analyzed using Excel 2010 software.Results A total of 247 articles were screened. SD rats (164 times, 65.86%) and Wistar rats (35 times, 14.06%) were often used to prepare PS animal models. Bilateral ovariectomy (139 times, 53.87%) and natural aging (43 times, 16.80%) were chosen as modeling methods. The ages of rats used for modeling ranged from 7 weeks to 18 months, with 3-month-old rats (22 times, 21.78%) being the most common. The detection indexes were comprehensively evaluated from multiple perspectives, including serum biochemistry, vaginal exfoliated cell smear, histomorphology, general observation, behavioral observation, and organ tissue protein immunoblotting. Western medical evaluation indexes were commonly used to test the successful preparation of models, with vaginal exfoliated cell smears being the most frequently used method (125 times, 85.04%). A model was considered successfully prepared when estrous cycle disorder or irregularity was observed. Some literature also determined modeling success by detecting a significant decrease in serum estradiol levels (5 times, 3.04%). Traditional Chinese medicine (TCM) syndrome evaluation often used a combination of Chinese and Western medical evaluation indexes for comprehensive evaluation, with researchers determining the TCM syndrome through vaginal exfoliated cell smears supplemented by general observation (3 times, 2.04%).Conclusion There are many methods for preparing PS animal models, but there are still significant differences in the selection of animal species, age, criteria for successful modeling, and TCM syndrome evaluation in the related literature.
5.Evaluation and Analysis of Modeling Methods for Animal Models with Diminished Ovarian Reserve
Hui HUANG ; Yasheng DENG ; Tianwei LIANG ; Yiqing ZHENG ; Yanping FAN ; Na RONG ; Jiang LIN
Laboratory Animal and Comparative Medicine 2023;43(4):422-428
ObjectiveTo analysis the modeling characteristics of diminished ovarian reserve (DOR) animal models, and provide the reference for the standardization of DOR animal models.MethodsThe research articles on DOR animal models were retrieved. Microsoft Excel 2010 software was used to summarize the experimental animal species, modeling methods, modeling cycles, high-frequency detection indexes and types of positive drugs documented in the literature, and the data results were evaluated and analyzed by NoteExpress software.ResultsA total of 93 research articles on DOR that met the criteria were enrolled. And it was found that, SD rat was the most frequently used animal type (68 times, 73.12%), followed by C57BL/6 mouse (13 times, 13.98%), while the tripterygium wilfordii treatment was the most frequently used modeling method (38 times, 40.86%), followed by the cyclophosphamide treatment (28 times, 30.11%) for DOR animal models. The high frequency detection indicators were vaginal exfoliation cytology detection (93 times, 23.97%) and HE staining to observe histopathological changes (72 times, 18.56%). Among these 64 research articles containing positive control drugs, the most frequently used western drug was estrogen (50 times,62.50%) and Chinese Traditional medicine was Kuntai capsules (2 times, 2.50%).ConclusionsSD rats are mostly used to induce modeling in animal experiments on DOR through tripterygium wilfordii and cyclophosphamide, which can effectively improve the experimental efficiency. It is recommended to integrate the results of ovarian histopathology and serum biochemical indexes for model assessment.
6.Application Analysis of Animal Models for Pelvic Inflammatory Disease Based on Data Mining
Yiqing ZHENG ; Yasheng DENG ; Yanping FAN ; Tianwei LIANG ; Hui HUANG ; Yonghui LIU ; Zhaobing NI ; Jiang LIN
Laboratory Animal and Comparative Medicine 2024;44(4):405-418
Objective To investigate the key elements for model establishment and determine the evaluation indicators of animal models for pelvic inflammatory disease (PID), providing a reference for improving modelling methods and optimizing the application of PID animal models. Methods The search query "Pelvic Inflammatory Disease" AND "Animal Model" OR "Rat" OR "Mouse" OR" Guinea Pig" OR "Rabbit" OR "Dog" OR "Pig" was used to retrieve relevant literature on PID animal models published from 2013 to 2023 in China Knowledge Network Infrastructure (CNKI), Wanfang, and PubMed databases. The studies were analyzed and categorized based on experimental animal types, modelling methods, modelling cycles, detection indicators, positive control drugs, and administration duration. A database was established for statistical analysis. Results A total of 214 research articles on PID animal models meeting the inclusion criteria were identified. The most commonly used model animals are Sprague Dawley (SD) rats, followed by Wistar rats. The most frequently employed modelling method is a combination of mechanical injury and bacterial infection, followed by the phenol mucilage method. The most common modelling cycles for acute pelvic inflammatory disease (APID) and chronic pelvic inflammatory disease (CPID)/sequelae of pelvic inflammatory disease (SPID) are 8 to 14 days, while for PID models without specific staging, the cycles are 7 days. High-frequency detection methods and indicators include histopathological observation using hematoxylin-eosin staining, enzyme-linked immunosorbent assay (ELISA) for serum-related indicators, morphological changes of tissues observed with the naked eye, and immunohistochemical detection of related protein expression in uterine tissues, and pathological scoring. The most frequently used positive control drugs are Fuke Qianjin Tablets, followed by Jingangteng Capsules. The most common administration duration for APID is 7 days, and for CPID/SPID models, it ranges from 15 to 21 days. Conclusion Currently, SD rats and Wistar rats are commonly used as experimental animals for PID models. The dual modelling method of mechanical injury combined with mixed bacterial infection aligns closely with clinical pathogenesis and can be used to establish a PID model that simulates postoperative uterine cavity infection. Depending on the research objectives, different positive drugs and detection indicators should be selected for comprehensive evaluation. Most existing PID animal model studies are based on western medical diagnosis, with fewer studies focusing on Traditional Chinese Medicine (TCM) syndromes. There is a need to integrate TCM theories of etiology and pathogenesis to construct PID animal models that are more in line with TCM clinical symptoms.
7.Total electric field intensity in workplace of high-voltage direct current converter stations
Guoyong XU ; Lei LIU ; Jianhui LI ; Jiao QING ; Bin LI ; Tianwei LI ; Ruiqin LU ; Hong SHI ; Xinqi LIN ; Danying ZHANG ; Bin XIAO
Journal of Environmental and Occupational Medicine 2023;40(8):931-935
Background The converter stations of high-voltage direct current (HVDC) transmission lines generate special total electric fields. At present, few investigations have been conducted on total electric fields in the workplace of converter stations from an perspective of occupational health. Objective To understand the current situation of total electric field strength in the workplace of converter stations. Methods Using purposive sampling, a calibrated HDEM-1 direct current (DC) total electric field strength measurement system was used to measure the total electric fields of 12 converter stations serving 6 DC lines in Southeast and Southwest China according to the Measurement method for total electric field strength and ion current density of the converter stations and DC transmission lines (DL/T 1089—2008). The results were evaluated according to occupational exposure limits recommended by The limits of electromagnetic environment at ±800 kV UHV DC converter station (DL/T 275—2012), the American Conference of Governmental Industrial Hygienists (ACGIH), and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Results A total of 615 check points were planned, the total electric field strength was 0.05-37.05 kV·m−1, and the median was 10.45 kV·m−1. The total electric field strength of 39 check points (6.3%) exceeded 25 kV·m−1 (the limits of ACGIH and ICNIRP), and the total electric field strength of 12 check points (2.0%) exceeded 30 kV·m−1 (the limit of DL/T 275—2012). There were statistically significant differences in the total electric field strength values and the proportions of exceeding 25 kV·m−1 between the neutral regions and the positive regions and between the neutral regions and the negative regions (P < 0.01). The proportion of total electric field strength exceeding 30 kV·m−1 in the negative regions was higher than that in the positive regions (P < 0.01). There were no significant differences in the total electric field strength of converter stations at different voltage levels and different altitudes (P > 0.05). There were no significant differences in the proportions of total electric field exceeding 25 kV·m−1 and exceeding 30 kV·m−1 in converter stations at different voltage levels and different altitudes (P > 0.05). Conclusion The total electric field in some workplace of converter stations exceeds selected limits. Converter station operators may be exposed to high-strength total electric field for a short time.