1.Monitoring of renal pelvic pressure and its siginifcance during flexible ureteroscopic lithotripsy
Sixing YANG ; Fu ZHENG ; Qin KE ; Chao SONG ; Lingqi LIU ; Wenbiao LIAO ; Tianpeng WU
Chinese Journal of Urology 2014;35(8):575-578
Objective To monitor the renal pelvic pressure and to investigate its clinical significance during retrograde flexible ureteroscopic lithotripsy (RFUL).Methods The data of renal pelvic pressure measured in 60 cases of RFUL with the mean irrigation pump speed and pressure of 30 ml/min and 30 mmHg were analyzed retrospectively.The influence factors of renal pelvic pressure and its correlation with postoperative fever were analyzed.Renal pelvic pressure was measured by baroceptor,which was connected to PHILIP-MP4 monitor IBP channel and ureteric catheter positioned in renal pelvis through a dual channel ureteral access sheath (UAS).The renal pelvic pressure data was collected and analyzed in every 2 seconds by computer.The 60 cases were divided into 3 groups according to their intra-pelvic pressure situations:normal pressure group(NP,IPPmax ≤30 mmHg),high pressure group(HP,IPPmax>30 mmHg,but high pressure duration≤ 10 min),and backflow pressure group(BP,IPPmax>30 mmHg and high pressure duration> 10 min).Results The baseline intra-pelvic pressure (IPP0) and max imum intra-pelvic pressure (IPPmax) were (13.2±5.6) mmHg and (95.6±2.3) mmHg respectively.IPP levels during the RFUL were significantly higher than the IPP0(P<0.001).There were 32,17 and 11 cases in NP,HP and BP groups,respectively.There were 6 cases with fever higher than 38.5 ℃ (10%),in which there were 1 case in NP,1 case in HP group and 4 cases in BP group.The postoperative fever rate in NP,HP and BP group were 3%,6% and 36% respectively,which were significantly different between groups(P<0.01).There were 12 cases with procalcitonin >0.1 ng/ml and 8 cases with procalcitonin >0.5 ng/ml,in which 2 cases in HP group and 6 cases in BP group.Conclusions RFUL would result in a temporal elevated intrapelvic pressure greater than 30 mmHg.Postoperative fever is relevant with renal perfusion pressure and perfusion time.It's necessary for the surgeons to adjust the perfusion pressure during operation.
2.Changes of protein kinase B and phosphorylation expression in the skeletal muscle, liver and pancreas of miniature pig model with type 2 diabetes mellitus model
Jian YU ; Disha ZOU ; Yao YE ; Suxian ZHOU ; Tianpeng ZHENG ; Fan YANG
Tianjin Medical Journal 2016;44(5):586-588
Objective To study the feasibility of Bama miniature pig model establishment of type 2 diabetes mellitus (T2DM) by high-fat and high-sugar diet combined with streptozotocin (STZ), and observe the changes in protein kinase B (PKB) and phosphorylation expressions in skeletal muscle, liver, and pancreatic tissues of the miniature pig model. Methods A total of 10 healthy male Bama miniature pigs were randomly divided into two groups:control group (n=5, fed normal diet) and diabetic model group (n=5, fed high-fat and high-sugar diet combined with STZ to establish T2DM Bama miniature pig model). The fasting plasma glucose (FPG) and fasting insulin (FINS) levels were measured, and insulin resistance (HOMA-IR) was calculated in two groups. The PKB and phosphorylation expressions in skeletal muscle, liver and pancreatic tissues were measured using Western blot assay. Results (1) After 10 months of high-fat and high-sugar diet, the body weight, FPG, FINS and HOMA-IR were significantly higher in model group than those of control group (P<0.01). (2) After STZ treatment, compared with control group, there was a further increased level of FPG and a significantly decreased level of FINS in model group (P<0.01). (3) Compared with control group, the PKB and phosphorylation expression levels in skeletal muscle, liver and pancreas were significantly lower in model group (P<0.05). Conclusion The high-fat and high-sugar diet combined with STZ can successfully establish the T2DM miniature pig model. The PKB and phosphorylation expression levels in skeletal muscle, liver, and pancreatic tissues are decreased in model pigs.
3.2019-nCoV and herpes simplex virus type I were simultaneously isolated from a case of COVID-19
Wei ZHANG ; Xiaofang PENG ; Huan ZHANG ; Zhe LIU ; Baisheng LI ; Tianpeng HUANG ; Changyun SUN ; Lirong ZOU ; Lijun LIANG ; Qianfang GUO ; Jie WU ; Hui LI ; Huanying ZHENG
Chinese Journal of Experimental and Clinical Virology 2021;35(6):714-718
Objective:To understand the etiology of a confirmed case of Coronavirus Disease 2019 (COVID-19).Methods:The pharyngeal swabs, serum and nasal swabs of a case of COVID-19 were inoculated into Vero-E6 cell tubes for virus isolation. The cytopathic effect (CPE) were observed daily. Collecting cell’s isolation when CPE was over 75%, after repeated freezing and thawing for 3 times, the supernatant was centrifugally taken, and the images of the virus were obtained by transmission electron microscopic observation, and the nucleic acid of the virus was extracted, second generation sequencing and sequence evolution analysis were used to identify and type the virus strains.Results:One strain of 2019 novel coronavirus (2019-nCoV) was successfully isolated from the nasal swab of this case of COVID-19, and one strain of herpes simplex virus type 1 (HSV-1) was also successfully isolated from the throat swab of the same case.Conclusions:COVID-19 cases have the possibility of co-infection with 2019-nCoV and HSV-1.
4.A prospective multicenter randomized non-inferiority clinical trial study of a domestic disposable digital flexible cystoscope versus a reusable Olympus digital flexible cystoscope
Yue XIA ; Zongwei PAN ; Guang SHAN ; Bin CHEN ; Ming LEI ; Wenbiao LIAO ; Liang CHEN ; Lingchao MENG ; Yunhe XIONG ; Hong ZHENG ; Huijun QIAN ; Tianpeng WU ; Sixing YANG
Chinese Journal of Urology 2022;43(9):690-695
Objective:To investigate the availability and safety of a domestic disposable digital flexible cystoscope compared with a reusable Olympus digital flexible cystoscope in cystoscopy and removal of double J stent.Methods:From August 2018 to March 2019, patients were enrolled in this prospective, open, multicenter, randomized, parallel positive controlled clinical trial study, which were from department of Urology in Renmin Hospital of Wuhan University, the First Affiliated Hospital of Xiamen University and the First Affiliated Hospital of Guangzhou Medical University. The experimental group and control group were assigned into a 1∶1 ratio by random table method. Inclusion criteria included age≥18 years and have indications for cystoscopy or removal of double J stent. Exclusion criteria included patients having acute genitourinary tract infection, having tuberculous bladder contracture, bladder capacity less than 50ml, having urethrostenosis, female menstrual period, pregnancy and lactation, having difficulty for lithotomy position, having serious cardio-cerebrovascular disease and liver or kidney dysfunction. A domestic disposable digital flexible cystoscope was adopted in the experimental group, whereas a reusable Olympus digital flexible cystoscope was used in the control group. Acceptability of image was defined as primary availability indicator, while success rate of working and performance score were defined as secondary availability indicators and mean operating time was calculated for cystoscopy only and cystoscopy plus removal of double J stent respectively, yet rate of adverse event as well as rate of equipment defects were sorted as safety indicators.Results:A total of 188 cases which were listed in per protocol set completed the clinical trial study successfully. There were 95 cases in the experimental group and 93 cases in the control group. Acceptability of image was 93.68%(89/95) and 96.77%(90/93) respectively in two groups( P=0.52). Success rate of working was 100.00%(95/95) and 98.92%(92/93) respectively in two groups ( P=0.49). Performance score was 14.41±0.93 and 14.56±0.84 respectively in two groups ( P=0.23). Mean operating time (MOT) only for cystoscopy was (15.3±2.6) min and (15.4±3.3)min respectively in two groups ( P=0.93), while MOT for cystoscopy plus removal of double J stent was (21.0±3.2) min and (21.7±3.9) min respectively in two groups ( P=0.69). Rate of adverse event was 8.42%(8/95) and 9.68%(9/93) respectively in two groups( P=0.76). There was no equipment defects in both groups. Conclusions:There is no statistical difference in acceptability of image, success rate of working, performance score, mean operating time for cystoscopy or removal of double J stent, rate of adverse events and rate of equipment defects. A domestic disposable digital flexible cystoscope has shown non-inferiority in the availability and safety compared with a reusable Olympus digital flexible cystoscope.