1.Effects of active component of Radix Isatidis on anti-anoxia and anti-fatigue in mice
Jiping LI ; Tingting SUN ; Tianjiao HU ; Moxiang LIU
Chinese Pharmacological Bulletin 2016;32(5):712-715
Aim To observe the effects of active com-ponent of Radix Isatidis ( ACRI ) on anti-anoxia and anti-fatigue in mice and investigate its possible mecha-nism. Methods Based on the weights, the mice were randomly divided into 5 groups: blank control group, ACRI 25, 50 and 100 mg·kg-1 groups, positive drug ( American ginseng liquid) control group 3 mL·kg-1 . Drugs were administered to the mice for about 14 con-secutive days, and during the experiment general situa-tions of mice were observed. The experiment of bearing hypoxia at normal pressure and the experiment of swim-ming while weight-bearing were conducted to study the effect of ACRI on anti-anoxia and anti-fatigue in mice. Then the superoxide dismutase ( SOD ) activities, the content of maleic dialdehyde ( MDA ) of mice serum and liver and blood urea nitrogen, blood lactic acid, liver glycogen were detected, in order to investigate its mechanism. Results ACRI decreased the growth rate of body weight in mice significantly, obviously pro-longed the survival time of anoxic mice at normal pres-sure and the swimming time of loaded mice, enhanced the SOD activities of mice blood and liver, decreased the MDA content of mice blood and liver, increased the content of liver glycogen, and decreased the blood urea nitrogen and blood lactic acid in mice after swim-ming. Conclusion ACRI has the anti-anoxia and anti-fatigue functions.
2.The study of simulation system for cardiopulmonary bypass cardiac surgery.
Tianjiao WEI ; Zhaoyan HU ; Zhenglong CHEN ; Chenglu SUN
Chinese Journal of Medical Instrumentation 2014;38(5):341-344
According to the clinical requirements of cardiopulmonary bypass surgery, this paper established a simulation system for cardiac surgery which consists of venous reservoir, variable balance chamber, blood suction bag, ventricle suction bag, resistance valves, pressure gauges and tubings. Using the proposed system, perfusionists can mimic the implementation of pre-established surgery strategy, predict various abnormal conditions in the operation, and accordingly take the urgent actions so as to improve the success rate of surgery and to ensure the safety of patients.
Cardiac Surgical Procedures
;
instrumentation
;
Cardiopulmonary Bypass
;
instrumentation
;
Catheters, Indwelling
;
Heart
;
Humans
;
Suction
3.Determination of serum creatinine by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method
Tianjiao ZHANG ; Haijian ZHAO ; Chuanbao ZHANG ; Jiangtao ZHANG ; Cuihua HU ; Ying YAN ; Donghuan WANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2009;32(5):509-514
Objective To develop a candidate reference method for the measurement of creatinine in human serum based on isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS). Methods An isotopically labeled internal standard [<'2>H<,3>] creatinine was added to the serum sample and equilibrated with the endogenous creatinine. The samples were treated with anhydrous ethanol to remove proteins by precipitation. After being washed with chloroform for further clean-up, the samples were analyzed by LC/MS/MS. Serum creatinine was quantified by a bracketing calibration. Results The within-run, between-run and total coefficients of variation ranged from 0.52% to 0.61%, 0.11% to 0.59% and 0.61% to 0.83%, and the averages were 0.57%, 0.43% and 0.73%, respectively. The analytical recoveries ranged from 99.09% to 101.13% with an average of 100.3%.The results of analyzing the certified reference material SRM 909b (Level Ⅰ and Ⅱ) and SRM 967b showed biases of less than 0.4%. Conclusions An ID-LC/MS/MS method for measuring serum creatinine has been developed. The method is highly precise and accurate and may be used as a candidate reference method for serum creatinine measurements.
4.The commutability of reference materials for serum glucose measurements
Tianjiao ZHANG ; Jie ZENG ; Mo WANG ; Chuanbao ZHANG ; Jiangtao ZHANG ; Haijian ZHAO ; Jing WANG ; Donghuan WANG ; Weiyan ZHOU ; Rong MA ; Cuihua HU ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2015;(5):296-300
Objective To evaluate the commutability of certified reference materials, external quality assessment program materials and calibrators for serum glucose measurements which were performed in 24 routine measurement procedures.Methods 35 fresh patient specimens and some reference materials were analyzed by isotope dilution liquid chromatography tandem mass spectrometry ( as the comparative method) and 24 routine measurement procedures (as the evaluated methods).The relationships between the results from the evaluated method and the comparative methods were evaluated to identify the commutability.Results It showed that 5 certified reference materials, 2 trueness verification materials, and 5 calibrators were commutable in all 24 routine measurement procedures.The other samples were displayed the presence of commutability issue in different degrees.Conclusion It is important to pay more attention to the problems brought by commutability of reference materials in clinical laboratory.
5.Quality assessment of seven kinds of sero-enzyme tests in China
Jing WANG ; Jie ZENG ; Ying YAN ; Haijian ZHAO ; Rong MA ; Jiangtao ZHANG ; Weiyan ZHOU ; Tianjiao ZHANG ; Cuihua HU ; Donghuan WANG ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2015;(5):313-317
Objective To evaluate the analytical quality of different analytical systems in measuring seven kinds of sero-enzymes consisting of Alanine Aminotransferase(ALT), Aspartate Aminotransferase (AST),γ-Glutamyltransferase(GGT), Lactate Dehydrogenase(LDH), Creatine Kinase(CK), α-Amylase (AMY) and Alkaline Phosphatase(ALP).Methods Data from 2013 routine chemistry external quality assessment (EQA) and Enzymes Trueness Verification(ETV) were collected.1 450 and 165 participating laboratories were selected respectively for investigation.Analytical systems of participating laboratories were classified into 6 kinds,i.e.imported matching system(AI), domestic matching system(AH), systems consisting of imported reagents and corresponding calibrators(BI), systems consisting of domestic reagents and corresponding calibrators ( BH ) , unmatched systems using imported calibrators ( CI ) and unmatched systems using domestic calibrators ( CH ) .Total error, bias and coefficient of variation within laboratories ( CVI) were calculated from the data of 2013EQA and ETV The proportion of laboratories meeting the desirable and the optimal criteria derived from biology variation were analyzedby EXCEL2010 with coincidence rate (CR) above 85% as evaluation criterion.Results The AI and CI occupied more than 70%among six systems, CH occupied approximate 15% and the other systems were less than 10%.The
range of the average of ETV′s total errors , EQA′s total errors, absolute value of bias and CVI of seven kinds of sero-enzymes were 6.2%-27.8%, 4.0%-7.0%, 4.2%-25.1% and 3.6%-4.6% respectively. Accuracy, bias and within-laboratory imprecision were judged by CR of ETV′s total errors, ETV′s bias, CVI and EQA′s total errors respectively and comparability between different systems was evaluated.It turned out that the results of analytical systems of enzymes except ALP were comparable, the accuracy of systems of enzymes except AMY, ALP and GGT, LDH of AI, the within-laboratory imprecision of enzymes except LDH, AMY, ALP and AST of AI, CH could meet the desirable criteria.The bias of all systems of seven kinds of sero-enzymes were undesirable.Conclusions The analytical quality of routine testing of seven kinds of sero-enzymes could fulfill the clinical requirement generally in China.
6.Determination of serum glucose by isotope dilution liquid chromatography tandem mass spectrometry
Tianjiao ZHANG ; Chuanbao ZHANG ; Jiangtao ZHANG ; Weiyan ZHOU ; Haijian ZHAO ; Ying YAN ; Cuihua HU ; Donghuan WANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2010;33(1):75-80
Objective To develop a candidate reference method for the measurement of serum glucose based on isotope dilution liquid chromatography tandem mass spectrometry(ID-LC/MS/MS)Methods An internal standard [~(13)C_6]glucose was added to serum samples and equilibrated with endogenous glucose.Serum proteins were removed by a precipitation with anhydrous ethanol.Serum glucose and the internal standard were then reacted with 1-phenyl-3-methyl-5-pyrazolone and the formed derivatives were analyzed by liquid chromatography tandem mass spectrometry with multiple reaction monitoring(MRM).The method was calibrated with bracketing calibrators and serum glucose concentrations were calculated by comparing the peak area ratios of samples with that of the calibrators.Results The within-run,between-run and total coefficients of variation averaged 0.36%,0.47%and 0.61%,respectively.The analytical recoveries ranged from 99.0% to 100.9%.Results of analyzing the certified reference material SRM 965a showed an average biases of-0.20%.Conclusions An ID-LC/MS/MS method for measuring serum glucose has been developed.The method is highly precise and accurate and may be used as a candidate reference method.
7.Determination of serum urea by isotope dilution gas chromatography mass spectrometry:a candidate reference method
Tianjiao ZHANG ; Jiangtao ZHANG ; Chuanbao ZHANG ; Haijian ZHAO ; Jing WANG ; Jiehong XIE ; Donghuan WANG ; Cuihua HU ; Rong MA ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(5):536-539
Objective To develop a candidate reference method for the measurement of urea in human serum based on isotope dilution/gas chromatography/mass spectrometry.Methods [13C,15N2]Urea used as internal standard Was added to the serum sample and equilibrated with endogenous nonlabeled urea.The serum samples were treated with anhydrous ethanol to emove proteins by precipitation.The serum urea and labeled urea were converted into a trimethylsilyl derivative of 2-hydroxypyrimidine and analyzed by gas chromatography/mass spectrometry system with selected ion monitoring.The concentration of serum ureaWas calculated by the theory of bracketing method.Results The average value of within-run oefficient of vailation(CV),between-run CV and total CV of the procedure were 0.38%(ranged from 0.12%to 0.47%),O.62%(ranged form 0.49% to 0.87%)and 0.73%(ranged from 0.51% to 0.93%).Respectively.The analytical recoveries ranged from 99.37% to 100.95%.The resuhs of analyzing the certified refefence material SRM909b(Level Ⅰand Ⅱ)showed a bias less than 0.2%.Conclusion The procedure for measuring urea in serum is a highly accurate and precise method and can be used as a candidate reference method for serum urea assays.
8.Evaluation of matrix effect of processed materials in serum total glycerol measurements
Weiyan ZHOU ; Haijian ZHAO ; Jiangtao ZHANG ; Tianjiao ZHANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Cuihua HU ; Donghuan WANG ; Wenxiang CHEN ; Chuanbo ZHANG
Chinese Journal of Laboratory Medicine 2008;31(5):568-573
Objective To evaluate the matrix effect of processed materials in serum total glycerol measurement and to assess the accuracy of routine test systems.Methods With an isotope dilution liquid chromatography tandem mass spectrometry method as the comparative method,matrix effects of 28 processed materials on 8 routine test systems were evaluated ccording to the NCCLS EP 14 protocol.The processed materials and 20 flesh patient specimens were analyzed with both the comparative method and each of the evaluated methods and results obtained with the two methods were plotted.Two-tailed 95% prediction intervals for the mean of the flesh patient specimen were computed and results on the processed aterials were compared with these intervals for evaluation of matrix effect.Results with the two methods on fresh samples were also compared for assessment of the accuracy of the routine test systems.Results Some of the processed samples showed matrix effects on some of the routine test systems.The observed matrix effects were system-specific and aused either positive or negative biases.Calibration biases were also observed on some test systems.Conclusion Matrix effect and calibration bias have been observed in serum total glycerol measurements.Continued efforts are needed for improving the accuracy of serum total glycerol measurements.
9.Evaluation of matrix effects in serum urea measurements
Haijian ZHAO ; Tianjiao ZHANG ; Chuanbao ZHANG ; Weiyan ZHOU ; Jiangtao ZHANG ; Jing WANG ; Jiehong XIE ; Rong MA ; Cuihua HU ; Donghuan WANG ; Ziyu SHEN ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(3):270-275
Objective To evaluate the matrix effects in serum urea measurements of external quality assessment(EQA)materials and commercial reference materials(calibrators or controls)on enzymatic methods and to verify the trueness of the enzymatic methods.Methods The Clinical and Laboratory Stadards Institute(CLSI)EP 14-A2 protocol was used for the evaluation of matrix effect.An isotope dilution gas chromatography mass spectrometry method was used as the comparative method.Twenty five fresh patient serum samples,15 EQA materials and 13 calibrators or controls were analyzed with 7 enzymatic methods (evaluated methods)and the comparative method and results were processed according to the protocol. The trueness of the evaluated methods were also assessed by comparing the fresh sample results obtained with the evaluated and comparative methods.Results Eight of 15 EQA materials and 3 of 13 calibrators or controls showed no matrix effects on all the 7 routine methods.One processed sample showed matrix effect on all the routine methods.Method dependent matrix effects of other materials were observed on other materials.Calibration biases were also observed on some enzymatic methods.Conclusions Matrix effects and calibration bias have been observed in serum urea measurements.Continued efforts are needed for improving the accuracy and the comparability of serum urea measurements.
10.Trueness evaluation of 13 routine measurements for serum uric acid
Jiangtao ZHANG ; Chuanbao ZHANG ; Jie ZENG ; Rong MA ; Haijian ZHAO ; Weiyuan ZHOU ; Tianjiao ZHANG ; Ying YAN ; Cuihua HU ; Jing WANG ; Donghuan WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2015;(9):609-612
Objective To evaluate the trueness of 13 routine measurements for serum uric acid and the role of reference method in improving harmonization and trueness among routine measurement systems. Methods The research is related to the reagent evaluation.Usingisotope dilution liquid chromatography tandem mass spectrometry ( ID-LC/MS/MS) method as the comparison method, Wako, Sekisui, DiaSys, Maker,Dirui,Leadman,BSBE,Biosina,Mindray,MedicalSystem,LongMarch,and Kehua 13 kinds of uric acid kits were chosen as the evaluation methods with Hitachi 7170A as the analyzer.serum uric acid in 40 fresh frozen serawere collected from clinical laboratory of Beijing hospital in 2014,coveringboth physiological and pathological status ( 80 -940 μmol/L ) .19 kinds of prepared materials and the 40 fronzen sera were measuredby comparison method and evaluation methods and linear regression analysis was made for the results.The performance of evaluation methods was revealed and recalibration was performed on every evaluation methodby the linear regression equation.The variation of percent bias(%) of the uric acid values in 19 preparation materials was compared.Results All test methods demonstrated good precision ( CV<1.75) and good correlation (R2 >0.998, P<0.01) with the comparison method when measuring uric acid values in 40 fresh frozen sera The meanpercent bias was 0.17% ( -3.06% -7.31%).After recalibration, 4 of 19 samples with no matrix effect values percent bias reduced and met the demands of quality ( <4.8%) induced from biological variation.Conclusion All test methods demonstrated good trueness and their calibration traceability was verified.Recalibration using reference method or standard reference materials contributes to harmonization among methods.