1.Implementation of Glucose Monitor System Following Introduction of Automated Ordering System
Yasuhiro SAIKI ; Fumie HIRASAWA ; Tatsuo ABE ; Kazuo EGUCHI ; Hideo FUKASAWA ; Hironobu KAKUTA
Journal of the Japanese Association of Rural Medicine 2004;53(4):679-684
Aichi Koseiren-Aihoku Hospital has implemented a New Glucose Monitoring System,using Precision PCx and its data management application, QC Manager (both Abbott Japan), for outpatient testing. It utilizes the advantages that have come with the introduction of the Ordering System. The new system has automated a great portion of glucose monitoring workflow and reduced the human work, and consequently, the potential risk of malfunction due to human errors. The system has been designed and developed to meet the following criteria; To be able to fully utilize the potential capabilities of the Ordering System (Barcode recognition of test samples); To be capable of transferring test results automatically to the Laboratory Information System without being handled by human; To improve the productivity as a whole system; To possess the precision and accuracy;and To be handled easily for bed-side use.
System
;
Human
;
Monitor
;
Glucose measurement
;
Following
2.A Fourteen-Day-Old Neonate with Congenital Aortic Valve Stenosis Successfully Treated with Open Valvular Commissurotomy.
Yuji HIRAMATSU ; Naotaka ATSUMI ; Masakazu ABE ; Tomoaki JIKUYA ; Yuzuru SAKAKIBARA ; Tatsuo TSUTSUI ; Kenji OKAMURA ; Toshio MITSUI ; Motokazu HORI
Japanese Journal of Cardiovascular Surgery 1993;22(5):437-440
A thirteen-day-old neonate was admitted because of systolic heart murmur, tachycardia, tachypnea and sucking weakness. The chest X-ray film demonstrated remarkable cardiomegaly and pulmonary congestion. Echocardiography detected marked thickening and stenosis of the aortic valve, and left ventricular dysfunction (EF=10%). The pressure gradient between left ventricle and ascending aorta was presumed 130mmHg with pulsed Doppler echocardiography, Since he did not respond to conservative treatment, an emergency open aortic valvular commissurotomy under cardiopulmonary bypass was performed the day after admission. We made incisions of 1mm in the left side and 0.5mm in the right side commissure of the adherent bicuspid aortic valve. After the procedure, left ventricular function improved (EF=57%), and the pressure gradient was reduced to 62mmHg. He showed good recover from the congestive heart failure. There are few reports about operative treatment of congenital aortic valve stenosis in neonates. This is considered to be the third youngest successful operative case of open aortic valvular commissurotomy in Japan.