1.A Pediatric Case of Infective Endocarditis with Pseudoaneurysm of the Sinus of Valsalva and Annular Abscess
Tomohito Kanzaki ; Masaaki Koide ; Yoshifumi Kunii ; Kazumasa Watanabe ; Takuya Maeda ; Yuko Ohashi
Japanese Journal of Cardiovascular Surgery 2014;43(5):260-264
Although aortic annular abscess and rupture of the sinus of Valsalva are known as complications of infective endocarditis, few cases in children have been reported. We report a surgical case of a 6-year-old girl with active infective endocarditis complicated with an annular abscess and pseudoaneurysm of the sinus of Valsalva. The patient presented progressive symptoms of heart failure and a subsequent echocardiogram demonstrated severe aortic regurgitation. A computed tomography indicated pseudoaneurysm of sinus of Valsalva and an emergency operation was performed. At operation, a bicuspid aortic valve with vegetation was noted. The annular abscess caused a large tissue defect of the left coronary sinus of Valsalva and formed a pseudoaneurysm. The infected lesion was resected completely. The defective aortic annulus and sinus of Valsalva were repaired with a bovine pericardial patch and aortic valve was replaced with a mechanical valve. The postoperative course was uneventful and the patient was discharged after adequate antibiotic treatment.
2.Utility of MRI in prostate cancer
Masami NIWA ; Hideto ANDO ; Itaru HIRAMATSU ; Eriko ITO ; Tuneo WATANABE ; Masao FUJIMOTO ; Daisuke MISAWA ; Nobuhito ONOGI ; Takuya KOIDE ; Manabu OKANO
Journal of the Japanese Association of Rural Medicine 2007;56(4):624-631
For diagnosis of prostate cancer, MRI was performed in 91 patients prior to prostate biopsy, and prostate cancer was detected in 37 patients. The ability of MRI diagnosis compared with biopsy was accuracy 0.84, sensitivity 0.95, and specificity 0.76.In 26 patients (14 patients with prostate cancer) from whom MR images were obtained by diffusion weighted imaging, ADC value and PSA value showed a reverse correlation significantly.The ADC value was 0.97±0.23-3mm2/sec in the cancer area, 1.51±0.20-3mm2/sec in the normal peripheral zone, and 1.47±0.12-3mm2/sec in the normal central zone. The ADC value in the cancer area was smaller than that in the normal peripheral area or in the normal central zone significantly (p<0.001).The relation between ADC value and Gleason score did not show any correlation. However, when the Gleason score was under 6, ADC value was 1.11±0.20-3mm2/sec, and when it was over 7, ADC value was 0.81±0.19-3mm2/sec which showed a lower value than the ADC value with Gleason score under 6 significantly (p<0.05).MRI was effective for visualization of prostate cancer. We concluded that pre-biopsy MRI in prostate cancer would allow not only systemic-biopsy but also accurate targeting-biopsy, and it would improve the diagnosric ability of biopsy.
Cancer of Prostate
;
biopsy characteristics
;
Magnetic Resonance Imaging
;
GLEASON GRADING FOR PROSTATIC CANCER
;
lower case pea