We present two cases of aged males with cold-induced colic successfully treated with tokishigyakukagoshuyushokyoto. The first case is a 74-year-old male with bilateral sciatic neuralgia, who had a history of right leg amputation following a traffic accident. The second case is an 80-year-old male with chills of the lower body, who has undergone excision of biliary duct cancer. Their physical status appeared normal to excessive by traditional medical examination, whereas the pulse and abdominal patterns are usually deficient in female cases in whom tokishigyakukagoshuyushokyoto is effective. The common features in our cases are age and history of trauma by injury or surgery. Although males are more tolerant of cold than females, advancing age and history of injury or surgery tend to cause cold-induced colic in males. The number of male cases that can be effectively treated with tokishigyakukagoshuyushokyoto is likely to increase in our aging society, and we conclude that it is important to consider the presence of cold when we examine male cases.
2.Usefulness of Fully Automated Hematology Analyzer XE-5000 for Analysis in Samples with Low Platelet Counts
Tatsuya KAWASAKI ; Keiji FUNAHASHI ; Eiko YAMADA ; Koji KOJIMA ; Takashi ISOMURA ; Toshihito SUZUKI ; Kazuo EGUCHI ; Takao OZAKI
Journal of the Japanese Association of Rural Medicine 2014;62(5):701-706
The platelet counts documented in most of the studies using the fully automated hematology analyzer XE-5000 are values measured by impedance technology (PLT-I). If blood specimens showing an anomalous particle-size distribution curve in the area where platelet counts are low are used (exceptionally low platelet count samples), the counting method is automatically switched over to an optical method (PLT-O). In the present study, we examined the usefulness of the XE-5000 by comparing PLT-I with PLT-O, using blood samples with low platelet counts collected from patients who visited our hospital between January 1 and March 31, 2012. Dilution linearity left nothing to be desired in either of the two, but simultaneous reproducibility was higher in PLT-O than in PLT-I. The correlations of PLT-I and PLT-O with visual counts were high, working out at r=0.889~0.984. In the exceptionally low platelet count samples, the correlation coefficient was high in PLT-O than in PLT-I. The cases showing low platelet counts frequently presented giant platelets and/or red cell fragments. Therefore, measuring the samples with low platelet counts requires a high degree of precision. In the samples with exceptionally low platelet counts, PLT-O exceeded PLT-I in simultaneous reproducibility and correlation with visual counts. Thus, our study demonstrated the usefulness of the XE-5000 that could enumerate PLT-O automatically and speedily.