1.Study on Quality Standard of Feireqingjie Oral Liquid
Yuexiao LAI ; Peiyi LIU ; Suying TIAN
Chinese Journal of Information on Traditional Chinese Medicine 2013;(11):51-52,53
Objective To study the quality control method of Feireqingjie Oral Liquid. Methods UV was used to determine the content of total flavonoid. Cortex Mori was identified qualitatively by TLC. Pheretima was identified qualitatively by PC. Results Total flavonoid showed a good linear relationship in the range of 0.005 26-0.052 60 mg/mL, r=0.999 8. The average recovery rate was 98.65%, RSD=0.28% (n=6). The TLC spot of Cortex Mori was coincident with the standard reference, and Pheretima showed the same color as the reference in PC, with no interference of negative control. Conclusion The method is convenient, accurate and can be used as one of the quality control methods of Feireqingjie Oral Liquid.
2.Blood coagulation function before and after peripheral blood stem cell mobilization and collection
Dan TIAN ; Gang WANG ; Suying HE ; Shaowen LI ; Chuxia GUO ; Yongzheng PENG ; Zhigang LU
Chinese Journal of Blood Transfusion 2022;35(1):32-34
【Objective】 To study the changes of blood coagulation function of donors before and after peripheral blood stem cell(PBSC)mobilization and collection, so as to evaluate the safety of the current scheme. 【Methods】 30 donors who received PBSC mobilization and collection in Zhujiang Hospital from October 2018 to October 2020 were enrolled. After mobilization by G-CSF, the correlation between coagulation function, blood routine indexes and TEG indexes of donors was analyzed, and the influence of PBSC mobilization and collection on coagulation function of donors was evaluated. 【Results】 The TEG indexes R(min), K(min), α(°), MA(mm) and CI before and after PBSC collection were 6.12±1.18 vs 7.25±2.16, 1.98±0.41 vs 2.45±0.64, 62.82±4.98 vs 57.3±6.67, 60.93±3.26 vs 55.37±4.41, and -0.31±1.40 vs -2.32±2.18, respectively(P<0.05), suggesting that there was no risk of hypercoagulability after PBSC mobilization and collection. The peak values of WBC (×109/L), Plt (×109/L) and Hb (g/L) were 62.02, 357 and 162, respectively, which indicated that the blood routine indexes after PBSC mobilization and collection were in the safe range. After PBSC collection, the CI value of 26.7% (8/30) donors was less than -3, showing hypocoagulability. 【Conclusion】 The current mobilization and collection scheme of PBSC has little effect on the coagulation function. Most of the donors had no risk of hypercoagulability, but a few showed a trend of hypocoagulability after PBSC collection.