1.Technique of minor- caliber and long balloon in treatment of lower limb peripheral arterial disease on diabetic patients
Yaoqiang LOU ; Kan XU ; Luyang MENG ; Linjun WANG ; Xiaodong WANG ; Songmao WANG ; Ye JIN
Chinese Journal of Primary Medicine and Pharmacy 2011;18(2):169-171
Objective To investigate the effect of percutaneous transluminal angioplasty(PTA) by minor-caliber and long balloon on diabetic patients with below-knee artery. Methods 16 consecutive DM patients(21 limbs)were treated with PTA by minor-caliber and long balloon and followed 7 months(1 ~22 months). The success rate,complication,clinical effects and the changes of ABI were investigated and analyzed. Results The technical success rate is 90.5% (19/21) ,no serious complication occurred. The clinical symptoms of all patients improved after successful PTA. The median ABI marginally increased from the baseline value of (0.31 ±0. 15) to (0.57 ±0.23) after intervention,the difference is significant (P < 0.05). Post-operative pain in patients with rest pain disappeared 9 (60.0%), relieved 4 (26.7%), reduce 2 (13.3 %). Ulcer healing in patients with foot gangrene 4 (66.7 %), Ulcer area was significantly reduced 1 (16.7%), high amputation 1 (16.7%). Postoperative follow-up, two limbs reoperation because of increased symptoms. Conclusion The treatment of percutaneous transluminal angioplasty by minorcaliber and long balloon was effective on diabetic patients with below-knee arterial disease.
2.Different position row of phlegm for decreasing the time of neurosurgery patients with tracheotomy lien impact study
Yaojuan WANG ; Songmao ZHOU ; Jingfang SHI ; Meiqin ZHU ; Lili ZHANG ; Zhiying GU
Chinese Journal of Practical Nursing 2018;34(23):1788-1791
Objective To explore the effect of sitting and lateral sputum aspiration on the retention time of tracheal cannula in patients with neurosurgical tracheotomy. Methods Totally 120 cases of neurosurgery tracheotomy in hospitalized patients complicated with pulmonary infection by random number table method, 58 cases were divided into experimental group and control group 62 examples, two groups of patients with sputum top all joint taps to the back of the chest, the experimental group after taps take seat effectively causes cough; In the control group, the lateral position was used to effectively cough or induce cough, and the daily sputum volume of the two groups of patients was observed. To observe the time when the body temperature was restored to normal after the phlegm of the two groups of patients, the time of the lung auscultation, and the time of the tracheal tube retention. Results Implementing position row of phlegm daily sputum volume within a week the experimental group were (44.84±6.85) ml, (44.60±6.80) ml, (43.79±5.98) ml, (44.38±5.42) ml, (42.22±5.45) ml, (38.12±4.77) ml, (36.88±4.57) ml and control group were(36.13±7.34) ml, (35.15±7.34) ml, (36.13±7.34) ml, (37.13±7.34) ml, (37.13±7.34) ml, (32.97±7.17) ml, (31.35±4.36) ml, the difference had statistical significance (t=4.30-7.31, P<0.01);In the two groups, the time of normal body temperature recovery, the time of hearing and the time of the lung and the time spent in the tracheal tube were compared, and the experimental group were respectively (9.93±2.02) d, (32.33±1.50) d, (37.33±1.50) d, while control group were(15.77±1.05) d, (37.63 ± 2.33) d, (42.63 ± 2.33) d, the difference had statistical significance (t=20.04, 14.71, P<0.01). Conclusions It is better to reduce the retention time of tracheal tube in patients with neurosurgical patients than the lateral position.
3.To evaluate the awakening effect of high-frequency repetitive transcranial magnetic stimulation in patients with chronic consciousness disturbance after brain injury based on magnetic resonance spectroscopy
Chaoyu WU ; Yi'an OUYANG ; Zhengbiao XUE ; Jiying LAI ; Songmao OUYANG ; Shusheng WANG ; Zihui SU ; Hongquan ZHU
The Journal of Practical Medicine 2024;40(4):554-560
Objective Evaluation of the efficacy of high-frequency repetitive transcranial magnetic stimulation for chronic disturbance of consciousness after severe craniocerebral injury based on magnetic resonance spectroscopy.Methods The clinical data of 106 patients with chronic disturbance of consciousness after severe craniocerebral injury from January 2018 to December 2022 were retrospectively analyzed,and they were divided into control group(conventional rehabilitation treatment)and observation group(high frequency repetitive transcranial magnetic stimulation treatment)by propensity score matching method(1∶1),with 53 cases in each group.Both groups were examined by magnetic resonance spectroscopy(MRS)before and after treatment.The brain metabolic indexes[N-acetyl aspartate(NAA)/creatine(Cr)value,choline complex(Cho)/Cr value],Glasgow coma scale(GCS)score,electroencephalogram(EEG)grading,coma recovery scale(CRS-R)score,brainstem auditory evoked potential(BAEP)grading,upper limb sensory evoked potential(SSEP)grading and Cerebral blood flow perfusion index[cerebral blood volume(CBV),mean transit time(MTT),cerebral blood flow(CBF)]were compared between the two groups.Results After treatment,the NAA/Cr values of the thalamus and brainstem in the two groups increased,while the Cho/Cr values decreased,and the levels of brain metabolic indexes in the observation group were signifi-cantly better than those in the control group(P<0.05).The two groups'GCS score and CRS-R score increased,and the improvement of the observation group was better than that of the control group(P<0.05).The BAEP grading,EEG grading,and SSEP grading of the two groups improved,and those of the observation group were better than the control group(P<0.05).The CBF and CBV of the two groups increased,and MTT decreased,and the level of cere-bral blood perfusion index in the observation group was better than that in the control group(P<0.05).Conclusion High frequency repetitive transcranial magnetic stimulation has a significant effect on the recovery of patients with chronic consciousness disorders after severe craniocerebral injury.The mechanism may be related to improving the blood flow velocity of brain tissue and metabolism in the brain.
4.Application of a new method for patient positioning based on optical surface monitoring technology to head radiotherapy
Yi DU ; Haizhen YUE ; Meijiao WANG ; Shun ZHOU ; Songmao YU ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2020;40(3):209-215
Objective:To develop a new method to set up patients using optical surface monitoring system and to compare it with the conventional method in head radiotherapy.Methods:A total of 358 set-ups (130 with the conventional method and 228 with the new method ), which were from 99 head tumor patients in Beijing Cancer Hospital treated between May 2018 to April 2019, obtained by using Image Guided Radiotherapy were retrospectively analyzed. The distributions of set-up errors, the number of abnormal positions, and the set-up time were compared to evaluate the potential advantages of the new method .Results:The mean (± standard deviation) absolute values of setup errors of the new method were (0.07±0.07) , (0.08±0.06) and (0.06±0.06) cm for the vertical, lateral, and longitudinal, (0.53±0.41)°, (0.59±0.44)° and (0.59±0.46)° for the rotation, pitch and roll, respectively. In the new method , the setup accuracy was improved( t=3.24-6.10, P<0.001)and the number of abnormal positions was greatly reduced(χ 2=60.66, P<0.001). Compared with the conventional method, the patient setup time was slightly reduced by the new method , but the difference was not statistically significant ( P>0.05). Conclusions:The new high-precision method to set up patients using optical surface monitoring system improves the accuracy of patients′ position, decreases the corrections applied by 6DoF couch, reduces the probability of abnormal positions, and suggests the potential benefit in head radiotherapy.
5.Evaluation of cost-effective ratio (imaging quality vs. radiation dose) of Varian cone beam CT based on figure of merit (FOM)
Junyu LI ; Hao WU ; Jingxian YANG ; Tingting LI ; Songmao YU ; Zihong LU ; Meijiao WANG ; Chenguang LI ; Weibo LI ; Yibao ZHANG
Chinese Journal of Radiological Medicine and Protection 2020;40(8):595-599
Objective:To analyze and compare the radiation dose and image quality of kilo-voltage cone beam CT systems on different Varian accelerator platforms, providing data to support clinical decisions on selecting optimal protocols for image-guided radiotherapy based on cost-effective ratio (image quality / radiation dose).Methods:The radiation dose and image quality of various CBCT systems and scanning protocols on Varian Edge, Truebeam and ix (new and old) LINACs were obtained using a CT dose index (CTDI) phantom combined with a CT ionization chamber and a Catphan604 phantom, respectively. Figure of merit (FOM) was used to evaluate the cost-effective ratio of the image guidance schemes.Results:Considerable inter-system varieties of FOMs were observed, varying from 0.65 (Image Gently-full trajectory) to 48.46 (Image Gently-half trajectory). The inter-protocol varieties were also large, where the mean±SD was 22.14±13.47.Conclusions:Considering the explicit inter-system and inter-protocol varieties, it is clinically favorable to evaluate the image guidance schemes based on machine-specific measurement. For instance, parameters and equipment with low CTDI w can be beneficial for dose-sensitive patients. High CNR regimen favors patients with high image quality requirements. For ordinary patients, cost-effective ratio in terms of FOM can be very helpful to guide the decision-making of clinical image-guided radiotherapy.
6.Workflow and error analyses of patient setup based on open-face mask immobilization combined with AlignRT for head tumor radiotherapy
Junyu LI ; Hao WU ; Jingxian YANG ; Shun ZHOU ; Zihong LU ; Songmao YU ; Jixiang CHEN ; Meijiao WANG ; Kaining YAO ; Yi DU
Chinese Journal of Radiological Medicine and Protection 2022;42(8):590-597
Objective:To propose a markless patient setup workflow based on the optical surface monitoring system (AlignRT) and open-face mask immobilization for whole-course head tumor radiotherapy, assess the setup time and repositioning frequency of the proposed workflow, and conduct a comparative analysis of the differences, correlation, and consistency of the setup errors of the AlignRT and cone beam CT (CBCT) systems.Methods:A retrospective analysis was conducted for the data on the errors of 132 fractionated setup based on open-face mask immobilization of 33 head tumor patients. AlignRT-guided markless patient setup workflow was applied throughout the radiotherapy. Meanwhile, the body structures automatically generated by the treatment planning system were used as body references. The 6-degree-of-freedom (6DoF) setup errors (lateral, vertical, longitudinal, rotation, pitch, roll, and yaw directions), setup time, and repositioning frequency of the AlignRT and CBCT systems were recorded and analyzed. The Wilcoxon and Spearman analyses were used to statistically assess the differences and correlation of the setup errors of the two systems. Moreover, the Bland-Altman analysis was employed to evaluate the consistency of the two systems.Results:The 6DoF setup errors of CBCT were within the clinical tolerance (linear motions: -0.30 to 0.30 cm; rotational motions: -2.0° to 2.0°). The setup time and repositioning frequency of CBCT were (98 ± 31) s and 1.51% (2/132), respectively. There was no significant difference in setup errors between the two systems except those in x-axis ( Z = -3.11, P= 0.002), y-axis ( Z = -7.40, P<0.001), and Pitch ( Z= -4.48, P<0.001). There was a significant positive correlation between the setup errors along lateral ( rs = 0.47, P<0.001) and vertical ( rs = 0.29, P = 0.001) directions, rotation (Rtn; rs = 0.47, P<0.001), pitch (Pitch; rs = 0.28, P = 0.001) and roll (Roll; rs = 0.45, P<0.001) of the two systems. The 95% limits of agreement (95% LoA) of 6DoF setup errors were -0.12 to 0.09 cm, -0.07 to 0.17 cm, -0.19 to 0.20 cm, -1.0° to 0.9 °, -1.0° to 1.5°, and -0.9° to 1.0°, respectively. The 95% confidence interval (95% CI) of 95% LoA was -0.14 to 0.11 cm, -0.09 to 0.19 cm, -0.23 to 0.23 cm, -1.2° to 1.1°, -1.2° to 1.7°, and-1.0° to 1.1°, respectively, all of which were within the permissible error ranges. The 6DoF setup error difference of 3.41% (27/792< 5%) was beyond the 95% LoA. The maximum absolute differences of 6DoF setup errors within the 95% LoA were 0.12, 0.16, 0.19 cm, 0.9°, 1.5°, and 1.0°, respectively. Conclusions:The proposed markless setup workflow based on AlignRT combined with open-face mask immobilization for whole-course head tumor radiotherapy exhibits reasonable agreement and consistency with the patient setup using CBCT, with acceptable clinical efficiency. It can be applied to the first radiotherapy and the real-time monitoring of therapy to improve the safety and thus is of value in clinical applications.