1.Preparation of two poor water soluble drugs - nanoporous ZnO solid dispersions and the mechanism of drug dissolution improvement.
Bei GAO ; Changshan SUN ; Zhuangzhi ZHI ; Yan WANG ; Di CHANG ; Siling WANG ; Tongying JIANG
Acta Pharmaceutica Sinica 2011;46(11):1399-407
Nanoporous ZnO was used as a carrier to prepare drug solid dispersion, the mechanism of which to improve the drug dissolution was also studied. Nanoporous ZnO, obtained through chemical deposition method, was used as a carrier to prepare indomethacin and cilostazol solid dispersions by melt-quenching method, separately. The results of scanning electron microscope, surface area analyzer, fourier transform infra-red spectroscopy, differential scanning calorimeter and X-ray diffraction showed that drugs were implanted into nanopores of ZnO by physical adsorption effect and highly dispersed into nanopores of ZnO in amorphous form, moreover, these nanopores strongly inhibited amorphous recrystallization in the condition of 45 degrees C and 75% RH. In addition, the results of the dissolution tested in vitro exhibited that the accumulated dissolutions of indomethacin and cilostazol solid dispersions achieved about 90% within 5 min and approximately 80% within 30 min. It was indicated in this study that the mechanism of drug dissolution improvement was associated with the effects of nanoporous ZnO carrier on increasing drug dispersion, controlling drug in nanopores as amorphous form and inhibiting amorphous recrystallization.
2.Anatomical study of plate invention for acetabular anterior column and baffle plate for acetabular quadrilateral body
Huiwen CHEN ; Zhengzhen ZHOU ; Chaojun WANG ; Rui ZUO ; Chunyun GUO ; Feng HUANG ; Yingdong FENG ; Bo WEI ; Zhen KONG ; Siling CHANG ; Yongjian SUN
Chinese Journal of Tissue Engineering Research 2017;21(11):1712-1717
BACKGROUND: It remains poorly understood whether anterior column quadrilateral wing plate exists to solve intraoperative multiple plastic and quadrilateral in vivo shift for treating acetabular anterior column and acetabular quadrilateral body fractures.OBJECTIVE: To figure out the promising application on measurement of anatomical character parameters when designing acetabular anterior column and acetabular quadrilateral body using Mimics software. METHODS: 60 pelvic CT scan data were collected and three-dimensionally reconstructed by Mimics software. The following anatomical character parameters were measured, including the angle between plane of arcuate line of true pelvis and plane of quadrilateral surface, the four boundary lines of quadrilateral body, and the thickness of substance of bone in quadrilateral region. The projection curve on quadrilateral surface of acetabular margin and dangerous zone for screw placement were both drew. Above all, the study attempted to find out the proper safe entry point of quadrilateral screw and to measure their leaning inside angles.RESULTS AND CONCLUSION: (1) The angle between plane of arcuate line of true pelvis and plane of quadrilateral surface was not significantly different between males and females. (2) The minimum thickness of quadrilateral body in males was larger than that in females. (3) The maximum leaning angle flapper plate screw P1 and P2 for quadrilateral body was significantly smaller in males than in females, but that of screw P3 was not significantly different between males and females. (4) The application of Mimics software made it easier, more intuitive and more practical for the design or development of new plate for acetabular anterior column and acetabular quadrilateral body. The common points and difference between acetabular anterior column and acetabular quadrilateral body could be specifically described by the new anatomical character parameters, which are defined by bone surface features of pelvis.