1.Gene Expression of Bone Morphogenetic Protein in Degenerated Cervical Intervertebral Disc:Immunohistochemical and in Situ Hybridization Studies
Yafer LI ; Shushan SHI ; Huaye DING
Orthopedic Journal of China 2001;8(2):158-160
Objective: To investigate the gene expression of bone morphogenetic protein(BMP)in human cervical disc.Methods:cervical disc specimen were obtained from patients undergoing anterior disc surgery,who had the signs of cervical disc herniation.Immunohistochemical and in situ hybridization studies were conducted to detect cells with BMP gene expression.Results:It showed positive staining of BMP-like immunohistoreactivity and its mRNA gene expression in degenerated discs,osteophytes,posterior longitudinal ligments,amd periosteum of vertebra.Conclusion:BMP may be relate to intervertebral disc degeneration as prolifertion-stimulating factor of chondrocytes that replace normal anular cells during disc degeneration but its mechanism needs further study.
2.Finite element analysis of the grafts used for acetabular revision in the presence of bone loss
Wenhui MA ; Xuemin ZHANG ; Jifang WANG ; Shushan SHI
Chinese Journal of Tissue Engineering Research 2010;14(9):1549-1554
BACKGROUND:Alternative implants affect stability of prostheses,and freeze-dried bone allografts are most selected as implants.The crack between grafts and host bone is unavoidable,which would weaken the bone integration.Bone cement can fill the cracks quickly and completely,however,the effects of bone cement on the stress of prostheses and its own remains poorly understood.OBJECTIVE:To evaluate the effect of the different grafting for bone loss in the presence of the new acetabular component with wings at the time of acetabular revision.METHODS:The finite-element models of acetabular component with three wings and acetabulum with bone loss were established.Following prostheses implantation,the gaps were filled with bone cement and freeze-dried bone allograft,respectively,stress of the graft and its effect on prostheses were analyzed under 2 158 N and 426 N acetabular loads.RESULTS AND CONCLUSION:The finite-element analysis demonstrated that stress and strain at the interfaces of bone-shell and metal-polyethylene liner had the same direction of change but no significant difference between them.In the study,the result indicated increased contact stresses with an increased hip force and orientation.The stress of wings increased gradually from rim to root.Its peak stress was at the joint between the wing and the shell.The different grafts did not affect the stress of the acetabular component.But the stress of bone cement was significantly higher than that of particulate bone.The study demonstrated that change of the graft could not make remarkable effect on the stress of the acetabular component.But the stress of bone cement increased significantly.The result of the finite-element analysis indicated that particulate bone graft is benefit to improving itsstability and to minimize aseptic loosening rate of acetabular component.
3.Finite element analysis of a new acetabular revision component with three wings compared with the uncemented hemispherical acetabular component
Wenhui MA ; Xuemin ZHANG ; Jifang WANG ; Shushan SHI
Chinese Journal of Tissue Engineering Research 2009;13(48):9423-9428
Alternative designs have been explored in an attempt to improve the longevity of acetabular prostheses in revision surgery. Many studies had been designed to test the result of the extra-large uncemented hemispherical acetabular components used for acetabular revision in the presence of bone loss. A clinical study of a new acetabular component consisting of a porous metal shell with three wings and an all-polyethylene liner had attained a satisfying result. The purpose of this study was to evaluate the new acetabular component by comparison with the hemispherical acetabular component. The finite-element models of the two acetabular components and the acetabulum in the presence of bone loss were established to calculate the interface stresses during a normal gait cycle with use of the finite-element formulations. Results of the finite-element analysis demonstrated that stress and strain of the two acetabular components had the same direction of change, but the new component had higher stress at the root of wings. In the study, the result indicated reduced contact stresses with a reduced abduction angle of wings. The stress was lower in the new acetabular component of 15° angle of wings compared with the new acetabularcomponent of 30°of wings and hemispherical acetabular component (P < 0.05). The stress of acetabular component with wings showed no remarkable difference by comparison with the extra-large uncemented hemispherical acetabular component. Reducing abduction angle of wings seemed to be a viable means of reducing the stress of the acetabular component while improving its stability.
4.Modeling and finite element analysis of a new acetabular revision component with three wings
Wenhui MA ; Xuemin ZHANG ; Jifang WANG ; Shushan SHI
Chinese Journal of Orthopaedics 2010;30(8):778-782
Objective To analyze and evaluate a new acetabular revision component with three wings. Methods The finite-element models of a new acetabular component and acetabulum with bone loss were established to calculate the interface stresses during a normal gait cycle with use of the finite-element formulations. Results The finite-element analysis demonstrated that stress and strain at the interfaces of bone-shell and metal-polyethylene liner had the same direction of change but no remarkable difference between them. In the study, the result indicated increased contact stresses with an increased joint load and orientation. The peak stress was tested at the second stage of gait cycle. The stress of wings increased gradually from rim to root. Its peak stress that was significantly lower than yield force of the Co-Cr alloy was at the joint between the wing and the shell. The stress of graft had the same change rule as the joint force. The part of graft near to acetabular component was subjected to higher stress conditions. Conclusion The hip forces can transfer from acetabular component and implant to acetabulum. The result of the finite-element analysis underlined the importance of wings of the new acetabular component. The wing can help to improve the antitorsion ability of acetabular component and to minimize its aseptic loosening rate. Therefore, based on results of this study and clinical application, the acetabular component with wings is known a viable means for acetabular revision in the presence of bone loss. But further research is needed as to this acetabular component.
5.Malignant Peripheral Nerve Sheath Tumors in the Pelvis and Sacrococcyx Originated from Neurofibromatosis: A Case Report and Literatures Review
Dajiang REN ; Fang LI ; Zhicheng ZHANG ; Kai GUAN ; Shushan SHI
Chinese Journal of Rehabilitation Theory and Practice 2013;19(3):290-293
Objective To observe the characteristics and treatment of malignant peripheral nerve sheath tumor originated from neurofibromatosis and the outcome of the patients. Methods A case was reported and the related literatures were reviewed. Results and Conclusion Malignant peripheral nerve sheath tumor is a rare soft tissue malignancy, which is with highly invasion. There are some difficulties with the diagnosis and treatment, and the outcome is poor. Early diagnosis is very important for treatment.
6.Meta-analysis of myeloperoxidase gene polymorphism and coronary artery disease susceptibility.
Luyao CHEN ; Shushan ZHAO ; Guangjie CHENG ; Ruizheng SHI ; Guogang ZHANG
Journal of Central South University(Medical Sciences) 2014;39(3):217-231
OBJECTIVE:
To assess the association between myeloperoxidase (MPO) gene polymorphism and coronary artery disease (CAD).
METHODS:
Several databases were used to retrieve relevant literature up to March 2013 by keywords. A Meta-analysis was performed by Stata12.0 software to estimate the pooled odds ratio (OR) and the 95% confidence interval (CI). Heterogeneity among studies was tested and sensitivity analysis was applied. Publication bias was examined using Begg's funnel plot and Egger's linear regression test.
RESULTS:
A total of 17 studies were included in this Meta-analysis. For MPO -463 G/A polymorphism, the pooled OR of A allele vs G allele was 0.58 [95% CI (0.47-0.72)] and the pooled OR of genotypes AA+AG vs GG was 0.58 [95% CI (0.46-0.72)]. In subgroup analysis of study population, AA and AG genotypes were significantly associated with CAD in Asians but not in Europeans. The MPO -463 G/A polymorphism in the stable angina pectoris subgroup was evaluated in 3 studies and the pooled OR of A allele vs G allele and genotypes AA+AG vs GG for proven CAD was 0.45 [95% CI (0.15-1.37)] and 0.57 [95% CI (0.19- 1.65)]. For MPO -129 A/G gene polymorphism, the pooled OR of genotype GG vs AA+AG was 0.91 [95% CI (0.74-1.10)].
CONCLUSION
A allele of MPO -463 G/A gene is associated with decreased risk of CAD except in the Europeans. There is no association between MPO -129 A/G gene polymorphisms and CAD risk.
Alleles
;
Asian Continental Ancestry Group
;
Coronary Artery Disease
;
genetics
;
European Continental Ancestry Group
;
Genetic Predisposition to Disease
;
Genotype
;
Humans
;
Odds Ratio
;
Peroxidase
;
genetics
;
Polymorphism, Single Nucleotide
7.Impact of artificial intelligence imaging optimization technique on image quality of low-dose chest CT scan
Lei ZHANG ; Hongkun SHI ; Shushan DONG ; Wan′an ZHU
Chinese Journal of Radiological Medicine and Protection 2020;40(9):722-727
Objective:To investigate the impact of artificial intelligence imaging optimization technique on the image quality and radiation dose of low-dose chest CT scan.Methods:Eighty patients who underwent chest CT examination in the Jilin University 1st hospital from July to August, 2019 were randomly divided into two groups(A, B), with 40 patients in each. The voltage of group A was 100 kV, while the other was 120 kV. According to different reconstruction method , group A was divided into two subgroups, group A1 and group A2. The images of A1 were reconstructed by iterative algorithm (ClearView 50%), while A2 images were optimized A1 by NeuAI imaging optimization technique. Group B used iterative algorithm (ClearView 50%) to reconstruct the image. The CT dose index (CTDI vol), dose-length product (DLP) and effective radiation dose ( E) of group A and group B were recorded and compared.Objective the evaluation indicators were CT noise (SD), signal-to-noise ratio (SNR) and comparative noise ratio (CNR) of ROI. Subjective evaluation was done by 2 chief radiologists using double-blind method and image quality was graded by 5-point Likert scale. Results:The patient characteristics between group A and group B showed no significant differences( P>0.05). Compared with group B, the effective radiation dose in group A was reduced by 72.1% [(1.48±0.49) mSv vs. (5.30±1.40) mSv]. The SD in group A1 was higher than that in group B, while SNR and CNR were lower ( ZSD=-4.24, ZSNR=-2.54, tCNR=-2.27, P<0.05). The SD in group A2 was significantly lower than that in group B ( ZSD=-28.24, P<0.001), and SNR and CNR were significantly higher than that in group B ( tSNR=-26.04, tCNR=-36.88, P<0.001). There was no significant difference in subjective scores of image noise between group A2 and group B, while subjective scores of lung structure in group B were better than those in group A2( χ2=4.96、7.04, P<0.05). Conclusions:Although the radiation dose was reduced by 72.1%, the low-dose chest CT images optimized by AI could reach the image quality level of standard dose.