1.Short-term effect of thymosin al combined with MVP chemotherapy on quality of life in patients with non-small cell lung
Dejie CHU ; Yong DU ; Shuigen GUO
Clinical Medicine of China 2009;25(11):1160-1161
Objective To explore the effect of thymosin and MVP chemotherapy on the life quality of non-small cell lung cancer(NSCLC) patients. Methods 50 cases of NSCLC patients who received MVP(MMC, VDS, DDP) chemotherapy,were randomly divided into experimental group (using thymosin α1) and control group;before chemotherapy and at the end of chemotherapy (the first 2 weeks), the quality of life was evaluated and analyzed comparatively by the FACT-L questionnaire of patients with lung cancer-Chinese version (V4.0). Results The re-sults of the experimental group score increased by (3.13±2.29),and control group score increased by(-1.07± 2.19) with significant differences (P<0.01). Conclusions Thymosin α1 can improve the short-term quality of life of the non-small cell lung cancer patients who received MVP chemotherapy.
2.Experimental study on implant-abutment locking force and abutment subsidence in a pure Morse taper connec-tion implant system
Bihui REN ; Yehao XU ; Jieting DAI ; Shuigen GUO ; Hongwu WEI
West China Journal of Stomatology 2024;42(3):372-381
Objective This test aimed to investigate the factors affecting the locking force between the implant and abutment and the amount of abutment subsidence in pure Morse taper connection implant systems.Methods With ref-erence to the Bicon implant abutment connection design,different types of implant specimens and their corresponding types of abutments were fabricated.The implant-abutment locking taper was uniformly 1.5°.The locking depths were 1.0,2.0,and 3.0 mm.The diameters of the locking column were 2.5,3.0,and 3.5 mm.The thicknesses of the outer wall of the implant were 0.15 and 0.30 mm.The loading forces of the testing machine were 200,300,and 400 N.At least 10 specimens of each group of implant-abutment were used.All specimens were loaded in the same manner using a univer-sal testing machine(finger pressure + specified loading force,five times).The total height of the implant-abut-ment was measured before finger pressure,after finger pressure,and after the testing machine was loaded for five times to calculate the amount of sinking of the abutment.Finally,the implant and abutment were pulled apart using the universal testing machine,and the subluxation force was observed and recorded.Results The test loading force,locking depth,and locking post diameter had an effect on the implant-abutment locking force and abutment subsidence.The implant-abutment locking force increased with the increase in the test loading force,locking depth,and locking post diameter(R=0.963,0.607,and 0.372,respectively),with the test loading force having the most significant effect.Abut-ment subsidence increased with the increase in test loading force(R=0.645)and decreased with the increase in locking depth and locking post diameter(R=-0.807 and-0.280,respectively),with locking depth having the most significant ef-fect on abutment subsidence.No significant correlation was found between the thickness of the outer wall of the implant and the change in the magnitude of the implant-abutment locking force.However,an increase in the thickness of the out-er wall of the implant decreased the amount of abutment subsidence,which was inversely correlated.Conclusion The locking force of the implant-abutment can be increased by adjusting the design of the pure Morse taper connection im-plant-abutment connection,increasing the locking depth and locking post diameter,and increasing the amount and num-ber of times the abutment is loaded during seating.Problems,such as loosening or detachment of the abutment,can be re-duced.The recommended abutment to be loaded should be no less than five times during seating to prevent the abutment from sinking and causing changes in the occlusal relationship in the later stages.Preliminary occlusal adjustments should only be conducted in the early stages of the use of temporary restorations,and final restorations and occlusal adjustments are recommended to be performed after using the abutment for a period of time.
3.Effect of inter-fractional positional uncertainty on cumulative dose of target volume in intensity-modulated radiotherapy of cervical cancer
Shuigen OUYANG ; Na TAO ; Tingting LIU ; Qing GUO ; Jianqiang CHENG ; Xiyi WEI ; Fali TAO ; Ruijun NIU ; Yongwei AN
Chinese Journal of Radiation Oncology 2021;30(8):822-827
Objective:To obtain the inter-fractional set-up errors of intensity-modulated radiotherapy (IMRT) of cervical cancer by cone-beam CT (CBCT), and to analyze the variations of the set-up errors on the cumulative dose deviation of the target volume.Methods:A total of 48 patients with cervical cancer who underwent IMRT were enrolled in this study, and the set-up errors of 696 CBCTs were obtained. The set-up errors were input into the treatment planning system, and the cumulative set-up error dose was obtained by superposing the set-up errors dose. The deviation percentage was calculated by the deviation formula and the standard planning dose.Results:The set-up errors caused the offset of isocenter distance by 0.58(0.36, 0.80) cm. Different statistical differences were noted between the cumulative set-up error dose and the standard planning dose by WilCoxon test. All the dose deviations in the target volume were reduced, and the differential dose volume histogram (DVH) appeared negatively skewed, and the peak value was declined. The DVH diagram shifted to the left with an inverse S-curve and the slope was increased. The HI deviation of the target volume from small to large were: CTV 1, CTV 2, GTV/CTV, CTV 3, CTV n, CTV all, and GTV nd; The HI deviation of the target volume were increased. Conclusions:The effect of set-up errors in IMRT of cervical cancer upon the cumulative doses of the target volume significantly differs. The cumulative dose of the target volume is reduced, and the uniformity of the target volume dose becomes worse. The uncertainty of the inter-fractional position leads to an increase or decrease in the the fractional doses of the target volume. The biological effect on tumor cells and the tumor recurrence remains to be investigated. In IMRT of cervical cancer, the CBCT position calibration is required before each treatment to ensure the dose accuracy of each structure in the target volume.
4.Immediate implantation of simple taper retentive implants in chronic apical infected teeth in the posterior region:a 5-year clinical observation
Xu ZHANG ; Shibo WEI ; Fei YU ; Hao WU ; Liangwei CAO ; Ning CAO ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2024;42(6):764-772
Objective This study aims to evaluate the mid-and long-term clinical efficacies of simple taper retentive implants for immediate placement in chronic apical infected teeth in the posterior region.Methods A total of 36 pa-tients with 41 simple taper retentive implants were included in the study conducted.These patients underwent immediate implant treatment for teeth with chronic apical infection in the posterior region.The soft and hard tissues surrounding the implants were assessed and documented over a period of 5 years following the completion of crown restoration.Re-sults During the 5 years follow-up period,one implant failed with mobility,and the implant survival rate was 97.6%.The mean marginal bone resorption was(-0.74±1.03)mm from the immediate post-implant placement to the immediate post-crown restoration,and the difference in marginal bone heights between the two time points was statistically signifi-cant(P<0.05).The mean marginal bone resorption was(-0.21±0.70)mm from the immediate post-crown restoration to the 5-year post-crown restoration,and the difference in marginal bone height between the two time points was not statisti-cally significant(P>0.05).No significant difference(P>0.05)was observed in bone resorption between mesial and distal,maxillary and mandibular,different tooth posi-tions,and different implant lengths.The soft tissue sur-rounding the implants remained healthy at the 5 years follow-up period,one implant exhibited peri-implantitis,and no mechanical complications were observed.The overall satisfaction of patients was good.Conclusion Immediate place-ment of simple taper retentive implants after thorough debridement of chronic infected alveolar socket in the posterior re-gion can achieve good mid-and long-term clinical outcomes after 5 years of loading.The soft and hard tissues were maintained in a steady state,which expanded the indications for immediate implantation.
5.Clinical efficacy of simple taper retentive implants in immediate posterior dental implantation for 5-7 years.
Bihui REN ; Shuigen GUO ; Yehao XU ; Jieting DAI ; Hongwu WEI
West China Journal of Stomatology 2023;41(3):341-349
OBJECTIVES:
This study aimed to evaluate the long-term clinical efficacy of simple taper retentive implants in the posterior dental area after immediate implantation for 5-7 years.
METHODS:
Selected from January 2015 to December 2017 in the Fourth Affiliated Hospital of Nanchang University dental clinic line tooth area immediately after the implant prosthesis, a total of 38 patients, 53 implants, were deep into (bone under 2 mm or higher) and the upper structure was repaired. In addition, after the completion of tracking observation of 60-90 months, the implant surrounding bone health was recorded and analyzed.
RESULTS:
After 5-7 years of follow-up, 1 of the 53 implants failed to fall out, and the implant retention rate was 98.1%. The amount of bone resorption in the proximal and distal margins 5-7 years after implant restoration was (0.16±0.94) mm and (-0.01±1.29) mm, respectively, and the difference in bone height between the proximal and distal margins of the implant and the immediate post-restoration period was not statistically significant (P>0.05). No statistically significant differences were found in the effects of periodontitis, implant site inflammation, and smoking on peri-implant marginal bone resorption (P>0.05).
CONCLUSIONS
The single taper-retained implant broadens the indications for immediate implant placement in the posterior region, and its deep sub-osseous placement (≥2 mm below the bone) avoids to a certain extent the disturbance of the implant by external stimuli and the exposure of the cervical abutment of the implant, with the good long-term stability of the marginal bone around the implant.
Humans
;
Dental Implantation, Endosseous
;
Dental Implants
;
Immediate Dental Implant Loading
;
Follow-Up Studies
;
Dental Implants, Single-Tooth
;
Alveolar Bone Loss/surgery*
;
Treatment Outcome
;
Dental Prosthesis, Implant-Supported
;
Dental Restoration Failure
6.A case of intramandibular epidermoid cyst and literature analysis.
Bihui REN ; Jieting DAI ; Yehao XU ; Shuigen GUO ; Hongwu WEI ; Weihua MAO
West China Journal of Stomatology 2023;41(4):478-482
Epidermoid cysts are generally benign neoplastic lesions, the etiology of which is unclear and is mainly related to epithelial cells left in the tissues during the embryonic period and traumatically implanted in the tissues. The most common intraosseous sites are the phalanges and the skull. Epidermoid cysts occurring in the jaws are clinically rare. In this paper, we report a case of epidermoid cyst occurring in the mandible with embedded teeth and discuss the etiology, clinical manifestations, diagnosis, and treatment of epidermoid cysts in the jaws in the context of the relevant literature.
Humans
;
Epidermal Cyst/surgery*
;
Skull
;
Mandible
;
Diagnosis, Differential
;
Epithelial Cells