1.Preparation Technology of Extraction and ? - cyclodextrin Inclusion of Volatile Oil in Shaofu Zhuyu Tablets
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(01):-
Objective To study the optimum conditions of extraction and ? - cyclodextrin inclusion for the volatile oil from Radix Angelicae Sinensis, Rhizoma Chuanxiong and Cortex Cinnamomi in Shaofu Zhuyu Tablets. Methods The extraction conditions were evaluated by the ultimate oil extract ratio with single- factor analysis, and the inclusion technology were optimized by the inclusion output ratio and oil- bearing ratio in the inclusion with orthogonal test. Results The optimum conditions for extraction were as follows: smashing the medicinal material into coarse powder (through 10- mesh screen), adding 8 times of the water (mwater ∶ mpander=8 ∶ 1), extracting oil for 4 hours. The best conditions for inclusion were as: the ratio of Oil and ? - cyclodextrin being 1 mL ∶ 8g, and stirring for 2 hours at 50 ℃ . Conclusion The extraction and inclusion conditions in this study are optimal with high oil extract rate, reasonable inclusion process, and minimum cost.
2.Determination of Schizandrin, Deoxyshizandrin and ?-Schizandrin in Jiangtang Soft Capsule by HPLC
Shudan ZHANG ; Sheng NI ; Aizhi YUAN
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(05):-
Objective To establish a method for the determination of schizandrin, deoxyschizandrin and ?-schizandrin in Jiangtang soft capsule. Methods The sample was extracted by methanol. The chromatographic conditions were: a gradient mobile phase of methanol-water(65: 35)within 0~20 rain and methanol-water(70: 30)within 20~80 min, the wavelength at 250 nm. Results A linear range of schizandrin, deoxyschizandrin and ?-schizandrin was within 0.71 ?g~3.53 ?g(r=0.99998, n=5), 0.19?g~0.95 ?g(r=0.99993, n=5)and 0.36?g~1.80?g(r=0.99997, n=5) and the average recoveries were 100.44%, 98.06% and 101.14% respectively. Conclusion This method is easy, sensitive, specific and accurate for the determination of schizandrin, deoxyschizandrin and ?-schizandrin in Jiangtang soft capsule.
3.HPLC Determination of Gardenoside in Xinxue Tablets
Shudan ZHANG ; Qiang XU ; Jiancheng TANG
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(02):-
Objective To establish a RP-HPLC method for the determination of gardenoside in Xinxue Tablets and to provide evidence for ameliorating its quality criterion.Methods HPLC conditions were as follows: C18(4.6?250 mm,5 ?m)column with temperature at 25 ℃,acetonitrile-water(15∶85) as mobile phase with flow rate of 1 mL/min,and the detection wavelength at 238 nm.Results Gardenoside was well separated from other components and had good linearity in the range of 0.128~1.024 ?g(r=0.999 2).The average recovery was 98.67 %and RSD=1.57 %.Conclusion The method is accurate,reproducible,and can be used for the quality control of Xinxue Tablets.
4.Assay of ephedrina hydrochloridum and pseudoephedrine hydrochloride in Chuanliting Spray by HPLC
Shudan ZHANG ; Zhengyan XIA ; Ying FENG
Chinese Traditional Patent Medicine 1992;0(09):-
AIM: To establish a RP-HPLC method for determining ephedrina hydrochloridum and pseudoephedrine hydrochloride in Chuanliting Spray(Herba Ephedrae,Folium Artenisiae argyi,Radix et Rhizoma Asari,etc.). METHODS: HPLC conditions were as follows: C_(18)(4.6 mm?250mm,5?m) column,0.2% phosphoric acid—acetonitrile(96∶4) as mobile phase with flow rate of 1mL/min,and the detection wavelength at 205nm.(RESULTS:) The calibration curve of ephedrina hydrochloridum was linear between 0.448-3.416?g(r=(0.999 8,) n=7).The average recovery was 100.26% and RSD=2.17%(n=5).The calibration curve of pseudoephedrine hydrochloride was linear between 0.16-1.12?g(r= 0.999 1,n=7).The average recovery was 101.60% and RSD =2.19%(n=5). CONCLUSION: The method is convenient and efficient,and can be used for quantitative analysis and quality control of this preparation.
5.Determination of Puerarin in Huanglian Jiangtang Tablets by HPLC
Zhengyan XIA ; Ying FENG ; Shudan ZHANG
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(06):-
Objective To establish a method for the determination of Puerarin in Huanglian Jiangtang Tablets. Methods The sample was extracted with 30 %ethanol. The chromatographic conditions were as follows:Diamonsil C18 chromatographic column(250 mm?4.6 mm,5?m)with a mobile phase of acetonitrile-0.5 %glacial acetic acid,the detection wavelength being at 250 nm and the flow rate being 1.0 mL?min-1. Results A linearity was obtained from 0.338 ?g to 2.336 ?g of Puerarin in Huanglian Jiangtang Tablets with a good correlation (r=0.999997,n=7).The average recovery was 100.2% and RSD=1.80%(n=6). Conclusion This method for determination of Puerarin in Huanglian Jiangtang Tablets is easy,sensitive,specific and accurate.
6.Determination of TanshinoneⅡA in Niaotong Tablets by TLC-scanning Method
Qiang XU ; Shudan ZHANG ; Ying FENG
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(06):-
Objective To establish a quality control method for tanshinone ⅡA in Niaotong Tablets.Methods The content of tanshinone ⅡA was determined by TLC-scanning method. Benzene-ethyl acetate(19 ∶1) was used as the developer, ?s = 470nm,?R = 620nm,SX=3.Results A linearity was obtained from 0.44?g to 2.20 ?g of tanshinone ⅡA in Niaotong Tablets (r=0.9993,n=5);the average recovery rate was 98.08 %,RSD=3.29 %.Conclusion This method is simple, sensitive and reproducible for the determination of tanshinone ⅡA in Niaotong Tablets and Radix Salviae Miltiorrhizae.
7.Determination of 5-O-Methylvisamminol in Shufeng Oral Liquid by HPLC
Qiang XU ; Shudan ZHANG ; Ying FENG
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(05):-
Objective To establish a method for the determination of 5-O-methylvisamminol in Shufeng oral liquid.Methods The sample was extracted with methyl and HPLC method was used.The chromatographic conditions were as follows: Alltima-C18 column(150 mm ? 4.6 mm,5 ?m)with a mobile phase of methanol-water(41∶59),the detection wavelength at 293 nm and the flow rate being 1.0mL?min-1.Results A linearity was obtained from 0.12 ?g to 0.84 ?g of 5-O-Methyvisammioside in Shufeng oral liquid with a good correlation(r = 0.99998,n = 7).The average recovery was 99.8 % and RSD = 2.05 %(n = 5).Conclusion This method for determination of 5-O-Methyvisammioside in Shufeng oral liquid is simple,sensitive,specific and accurate.
8.Endoscopic diagnosis and treatment for post cholecystectomy bile duct stenosis in 120 cases
Shudan LI ; Hangbin JIN ; Xiaofeng ZHANG ; Wen LYU ; Xiao ZHANG ; Jian ZHANG
Chinese Journal of General Surgery 2015;30(12):953-956
Objective To evaluate endoscopic management of bile duct benign and malignant stenosis after cholecystectomy.Methods A retrospective analysis was made on 120 bile duct benign and malignant stenosis developed after cholecystectomy, ERCP diagnosis and treatment was evaluated.Results Of the 120 cases, there was bile duct stenosis in 79 cases (including 61 cases with common bile duct stones), papillary inflamnatory stenosis in 15 cases, diverticulum associated duodenal papillitis in 8 cases, malignant biliary stricture in 8 cases.Among these 120 cases there were hilar benign stenosis in 3 cases, 3 cases with hilar malignant tumor, 4 cases of chronic pancreatitis.Benign bile duct stricture was treated with plastic stent drainage, concomitant calculi by endoscopic stone extraction.Papillary stenosis and papillitis were managed by EST or EPBD, inoperable malignant biliary stenosis by mental stent placement.Conclusions After cholecystectomy biliary stenosis treated by ERCP and endoscopic therapy is miniinvasive helping control biliary infection when the diagnosis of benign stenosis of bile duct is established.
9.The changes of the shear wave velocities on thyroid tissues in patients with Graves disease and its correlation with thyrotropin
Hongxia LUO ; Shudan ZHAO ; Xiaohua WANG ; Pintong HUANG ; Fuguang HUANG ; Chunpeng ZOU ; Yi ZHANG
Chinese Journal of Ultrasonography 2011;20(11):962-964
Objective To investigate the changes of the shear wave velocities on thyroid tissues in patients with Graves disease(GD) and its correlation with thyrotropin (TSH).Methods Forty GD patients and 30 health adults who underwent an ultrasound-based acoustic radiation force impulse (ARFI) technique,the shear wave velocity of thyroid tissues was obtained using virtual touch tissue quantification (VTQ) of ARFI technique,and the changes of the shear wave velocities on thyroid tissues with GD patients and its correlation with the serum TSH level were analyzed.Results The shear wave velocities of thyroid tissues in patients with GD was lower than that of normal,thas were significant difference( P <0.05),but there were no significant differences among different locations in GD patients( P >0.05).The shear wave velocities of thyroid tissues were correlated with the serum TSH level in patients with GD,the correlation coefficient was 0.707.Conclusions The shear wave velocity may be considered as a helpful index in diagnosing GD and indirectly reflect the serum TSH level,provide some reference for therapy of the GD.
10.Single-balloon enteroscopy assisted ERCP for diagnosis and treatment of patients with biliary obstruction after gastrointestinal reconstruction
Hangbin JIN ; Xiaofeng ZHANG ; Shudan LI ; Jianfeng YANG ; Weigang GU ; Qifeng LOU
Chinese Journal of Digestive Endoscopy 2013;30(9):499-502
Objective To evaluate the feasibility and safety of performing endoscopic retrograde cholangiopancreatography (ERCP) assisted by single-balloon enteroscopy (SBE) in patients with biliary obstruction after gastrointestinal reconstruction.Methods Clinical data about 7 cases of single-balloon enteroscopy assisted-ERCP (SBE-ERCP) were summarized including the completion of treatment,operation time,and complications for retrospective study.Results The papilla or anastomotic site was reached and therapeutic ERCP were performed successfully in 6 patients.The overall success rate was 85.7% (6/7),and the mean operation time of SBE-ERCP was 42 min (ranging from 28 to 72 min).The afferent loop and papilla were failed to be confirmed in 1 patient.No complication such as perforation,pancreatitis or bleeding ocurred in all the 7 patients.Conclusion Single-balloon enteroscopy assisted-ERCP (SBE-ERCP) is feasible and relatively safe in postsurgical patients with gastrointestinal reconstruction.