2.The myocardial injury after limb ischemia/reperfusion in rats and the protective effects of NO on myocardium.
Li-Jun ZHAO ; Guo-Xian DUAN ; Shu-Yun DONG
Chinese Journal of Applied Physiology 2007;23(3):268-327
Animals
;
Extremities
;
blood supply
;
Ischemia
;
metabolism
;
Male
;
Myocardial Reperfusion Injury
;
metabolism
;
Nitric Oxide
;
blood
;
Oxidative Stress
;
Rats
;
Rats, Wistar
3.Research of induced pluripotent stem cells in oral tissue regeneration.
Su JIANG ; Shu-juan GUO ; Jia-jun CHEN
Chinese Journal of Stomatology 2012;47(5):318-320
Animals
;
Bone Regeneration
;
physiology
;
Cell Differentiation
;
Dental Enamel Proteins
;
pharmacology
;
Dental Pulp
;
cytology
;
Fibroblasts
;
cytology
;
Gingiva
;
cytology
;
Guided Tissue Regeneration, Periodontal
;
methods
;
Humans
;
Induced Pluripotent Stem Cells
;
cytology
;
physiology
;
Mouth Mucosa
;
cytology
;
Periodontal Ligament
;
cytology
;
Tissue Engineering
;
methods
4.Recombinant human erythropoietin in the treatment of cisplatin-based-chemotherapy-induced a-nemia
Guo-Hong SONG ; Shu-Jun LIU ; Li-Jun DI ; Al ET
China Oncology 2001;0(05):-
Purpose:To study the efficiency and the safety of recombinant human erythropoietin (rHuEPO) in the treatment of chemotherapy-induced anemia.Methods:41 tumor patients were randomized into two groups:EPO-treatment group and control group,in order to observe the changes of the haemoglobin level,transfusion requirement and quality of life for the two groups respectively.Results:①the increase of haemoglobin level and the quality of life in the EPO-treat- ment group compared with that in the control group was statistically significant.②the reduction of transfusion requirement in the EPO-treatment group compared with that in the control group was not statistically significant.③treatment of EPO has few side-effects and a good tolerance.Conclusions:rHuEPO in the treatment of chemotherapy-induced anemia is effec- tive and safe.Not only can it increase the haemoglobin level but also improve the quality of life for the patients,so it should be used widely.
5.Biological variations of serum lipoprotein subfractions and high-density lipoprotein cholesterol esterification rate
Hanbang GUO ; Hongxia LI ; Yong MAN ; Shu WANG ; Jun DONG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2011;34(12):1135-1138
ObjectiveTo investigate the biological variations ( CVI,CVG ) of serum high-density (HDL2-C,HDL3-C ) and low-density (LDLa-C,LDLb-C ) lipoprotein subfractions and high-density lipoprotein cholesterol esterification rates (FERHDL and MERHDL ).MethodsTwenty healthy volunteers,10 males and 10 females,were recruited for this study from September to October,2010.Blood was collected four times from each individual with a 2-week interval between each sampling.Serum lipoprotein subfraction cholesterol levels were measured by ultracentrifugation/HPLC,FERHDL and MERHDL were measured by HPLC.Within-subject ( CVI) and between-subject ( CVG.) biological variations and quality specifications for precision,bias and total error were calculated.Results The average CVI of this group were 5.5% and 7.2% for HDL3-C and HDL2-C,11.2% and 18.7% for LDLa-C and LDLb-C,11.95% and 12.3% for FERHDL and MERHDL,respectively.The CVG for HDL2-C was 45.5%,much higher than that of HDL3-C (8.7%),and FERHDL(49.5% ) had a higher CVG than MERHDL (30.6% ).For each analyte,there was a considerable variation of CVIamongindividuals.ConclusionsBiologicalvariationsof lipoprotein subfractions,FERHDI and MERHDL have been estimated.These rsults will play an important role in quality specifications and cardiovascular disease risk assessment.
6.Determination of serum cotinine by isotope dilution liquid chromatography tandem mass spectrometry
Ruiyue YANG ; Weiyan ZHOU ; Tianjiao ZHANG ; Hanbang GUO ; Hongxia LI ; Shu WANG ; Jun DONG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2012;35(4):333-338
Objective To establish a method for measuring serum cotinine by isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) and provide an assay that can be applied to theevaluation of the level of smoke exposure and to the risk analysis of smoking related diseases.Methods Blood samples were collected from 94 apparently healthy subjects from October to December in 2010 and centrifuged,and the sera were separated.Serum samples were mixed with [ D3 ] -cotinine ( as the internal standard) and treated with acetonitriles to precipitate protein.After centrifugation,the supernatants were transferred and evaporated under a stream of nitrogen until dryness and reconstituted with mobile phase.Then the residuals were analyzed by LC/MS/MS system with multiple reaction monitor model; the concentration of cotinine were quantified by the isotope internal standard method and the stand curve was employed with a series of calibration.To estimate the precision of the method,five frozen serum pools were repeatedly analyzed in five runs,and every pool was analyzed in triplicate.In addition,the recovery rates were analyzed with the serum sample added with different levels of standard.The stability of cotinine in serum preserved at room temperature,4 ℃ and - 80 ℃,respectively.Finally,the levels of cotinine of 94 healthy subjects were measured to evaluate the distribution of cotinine with different smoke statuses.Results Serum cotinine measured by ID-LC/MS/MS was separated well with few interferences.The correlation coefficients between the peak area ratios and cotinine concentrations were higher than 0.9993.The values of within-run coefficients of variation (CV) of five frozen serum pools (0.68,48.42,94.34,250.95 and 287.04 μg/L) were 2.19%,0.78%,0.75%,0.65% and 0.67%,respectively.The values of total CV were 4.71%,1.40%,1.98%,1.10% and 1.03%,respectively.The limit of detection (LOD) and limit of quantitation ( LOQ ) were 0.013 and 0.050 μg/L,respectively.The analytical recoveries ranged from 99.22% to 102.67%.The samples could maintain stability within 2 d at room temperature,7 d at 4 ℃ and 3 months at -80 ℃ resulting the accuracy of measurements from 99.28% to 100.87% and the CV<5%.The levels of cotinine of 94 healthy subjects were measured and shown skewed and leptokurtic distribution.The concentrations of twenty smokers,fourteen former smokers and sixty non-smokers were 116.40 (63.17 -241.12),0.67 (0.15 - 0.95 ) and 0.22 (0.15 - 0.42 ) μg/L,respectively.Furthermore,the level of cotinine of former smokers (Z =-2.12,P <0.05) and smokers (Z =-6.67,P <0.001) were statistically higher than non-smokers.Conclusions An ID-LC/MS/MS method for serum cotinine detection has been established.It is hoped that the method will be applied to the assessment of smoke exposure and its association with the risks of smoking related diseases since it is simple,specific,precise,sensitive and accurate.
7.Serum cholesteryl ester n-3 fatty acid analysis by high performance liquid chromatography
Ruifang CUI ; Jun DONG ; Weiyan ZHOU ; Hanbang GUO ; Hongxia LI ; Yong MAN ; Shu WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2010;33(5):400-404
Objective To develop an HPLC method for the measurement of n-3 fatty acid index of serum cholesteryl esters.Methods Serum triglycerides were hydrolyzed with ethanolic sodium hydroxide and cholesteryl esters (CEs) were extracted with hexane.The extracted CEs were analyzed by reversed phase HPLC with a UV detection at 205 nm.Cholesteryl eicosapentaenoate and docosahexaenoate ( major n-3 fatty acid cholesteryl esters) were identified by liquid chromatography-tandem mass spectrometry and cholesterol in each CE fraction was measured.Peak areas of CEs were corrected for cholesterol and CE n-3 index was calculated using the corrected peak area and expressed as the percentage of n-3 fatty acid CEs in total CEs.Results The HPLC analysis can be finished in 6 minutes.Triglycerides which interfere with the determination of n-3 fatty acid index, were hydrolyzed with ethanolic sodium hydroxide (4 mol/L) in 30 seconds.The within-run and total CVs for CE n-3 index averaged 0.66% and 0.90%, respectively.CE n-3 indexes of 70 volunteers and 36 coronary heart disease patients apparently healthy subjects and patients with coronary heart disease in Beijing Hospital appeared to be positively skewed and leptokurtic distribution ( skewness = 1.25, kurtosis = 1.70 ).The median of n-3 indices were 0.98% ( 0.37% - 2.40% ).The logarithm of n-3 index appeared to be normal distribution and the average is 0.003 7% with standard deviations of 0.15.The distribution of n-3 indices of gender groups was similar with the total.The medians of females and males were 1.08% (0.60% -2.40%) and 0.95% (0.37% -2.11%) respectively, and the former were significantly higher than the latter( t = - 3.021, P = 0.003 ).Conclusion A new method for the measurement of n-3 index of serum cholesteryl esters by HPLC has been established.It is simple and precise and can be used in predicting cardiovascular diseases risks and monitoring dietary intake of n-3 fatty acids.
8.Evaluation of the Performance of 7 homogeneous direct reagents for HDL-cholesterol
Haijian ZHAO ; Hanbang GUO ; Chuanbao ZHANG ; Hongxia LI ; Jun DONG ; Shu WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2009;32(5):521-525
Objective To evaluate the analytical performance of 7 homogeneous HDL-cholesterol reagents. Methods An altracentrifugation-HPLC method was used as the comparison method. Fourty fresh patient samples were analyzed by homogeneous methods and the comparison method. The homogeneous methods were all performed on a Hitachi 7170A chemistry analyzer according to the manufacturer's instructions, Precision, accuracy and total errors were analyzed. Results The homogeneous assays typically demonstrated within run coefficient variance(CV) of < 1%, and total CV of < 3%. Methods A, B and D showed average bias, bias at the medical decision points and total errors all within the NCEP performance criteria and method C and F unacceptable biases (-19.74% and 11.46%, respectively) and total errors according to the NCEP criteria. However, all the homogenous methods (A-F) had total errors of < 30%, as required by the US Clinical Laboratory Improvement Amendment (CLIA). Conclusions Homogeneous HDL-C assays have been shown to be reasonably precise, but discrepant results have been observed with some of the assays. Clinical laboratories should pay more attention on selecting and validating homogeneous HDL-C reagents.
9.Cholesterol reference method and HDL cholesterol designated comparison methods as Performed in the US CDC Cholesterol Reference Method Laboratory Network
Hongxia LI ; Hanbang GUO ; Yong MAN ; Jun DONG ; Wenxiang CHEN ; Shu WANG
Chinese Journal of Laboratory Medicine 2009;32(5):504-508
Objective To standardize total cholesterol (TC) and HDL cholesterol (HDLC) analytical systems with the US CDC TC reference method and HDLC designated comparison method (DCM). Methods CDC TC reference method and HDLC DCM were set up and the quality was controlled by participating in the CDC Cholesterol Reference Method laboratory Network (CRMLN) bimonthly survey. The performance of 21 TC or HDLC analytical systems from 3 manufacturers were tested with the methods according to the CRMLN certification protocols. Results The coefficient variation (CV) of TC analyses with the reference method in 18 surveys averaged 0.29% and the bias versus CDC target value 0.1%. The DCM HDLC CV in 17 surveys averaged 0.010 mmol/L(0.39 mg/dl) and the averaged biases versus CDC target and group mean were - 0.019 mmol/L (-0.72 mg/dl) and - 0.006 mmol/L (-0.25 mg/dl), respectively. Most of the TC and HDLC analysis events (> 90%) satisfied the CRMLN accuracy and precision criteria for the reference method and DCM. Eighteen of the 21 tested TC or HDLC systems met the performance criteria for analytical systems and were certified for traceability by CDC. Conclusions A reference method for cholesterol and a DCM for HDLC and performed within an international reference laboratory network have been established and used for certification of TC and HDLC analytical systems, Further application of the methods to the standardization of lipid analysis are expected.
10.Fractional and molar esterification rate of high density lipoprotein cholesterol determined by high performance liquid chromatography
Tao PENG ; Jun DONG ; Hongxia LI ; Hanbang GUO ; Yong MAN ; Shu WANG ; Wenxiang CHEN
Chinese Journal of Laboratory Medicine 2008;31(4):415-420
Objective To develop an HPLC method for the measurement of fractional and molar esterification rate of serum HDL(FER HDL and MERHDL).Methods Blood samples were mixed with 5,5'-dithiobis-(2-nitrobenzoic acid)(DTNB)and the sera were separated.Serum HDL fractions were prepared by precipitation with Dextran sulfate and magnesium and the fractions were incubated at 37℃for 1 h in the presence and absence of 2-mercaptoethanol(ME).Free cholesterol levels of the HDL fractions were analyzed by HPLC and FERHDL and MERHDL were calculated.Results Under the selected conditions,serum free cholesterol could be stabilized by inhibition of LCAT with DTNB and the inhibition be reversed by ME. The total CVs for FERHDL and MERHDL were 1.59%-3.74% and 1.64%-2.88%,respectively.The averages of FERHDL and MERHDL in 70 apparently healthy subjects were 18.7%/h and 42.7 μmol·L-1·h-1 with standard deviations of 7.2%/h and 11.8 μmol·L-1·h-1·respectively,and the medians were 16.1%/h and 11.8 μmol·L-1·h-1.Close correlations of FERHDL.and MERHDL with other cardiovascular disease risk factors were observed.Conclusion A new method for the measurements of FERHDL and MERHDL by HPLC has been estabished. The method is safe, precise and simple and applications in the assessment of cardiovascular diseases risks are expected.